show network-clock ptp
Description
Show the PTP clock recovery state information. The clock recovery using PTP event
messages undergoes the following servo state changes:
- Warmup - The local reference
clock is in warmup state.
- Fast Loop - The local reference
clock is being corrected and the correction is converging.
- Bridge - The local reference
clock correction has been interrupted due to changes in the clocking information in the
received PTP event messages or loss of PTP event messages.
- Holdover - Prolonged loss of PTP
event messages puts the local reference clock correction to holdover state.
- Normal - The local reference
clock correction has converged and the corrected clock is synchronous to the master clock
information received in the PTP event messages.
Usage Guidelines
See
Description.
Example
# show network-clock ptp
=====================================================================
Servo State Information
=====================================================================
Servo State : 3 (Normal Loop)
Servo State Duration : 10285 (sec)
=====================================================================
History
This command was first available in ExtremeXOS 15.1.
Platform Availability
This command is available on the 7520-48Y and 7720 platforms.

Note