Displays detailed system-related information.
| mgmt | Specifies the management port. |
| port_list | Specifies one or more ports of slots and ports. |
| tag | Specifies an 802.1Q or 802.1ad tag value. |
| detail | Specifies detailed port information. |
N/A.
This command displays information, including the following:
If you do not specify a port number, range of ports, or tag value, detailed system-related information is displayed for all ports. The data is displayed in a table format.
The tag value may be associated with either a VMAN or a VLAN.
This status information may be useful for your technical support representative if you have a network problem.
The detail parameter is used to provide more specific port information. The data is called out with written explanations versus displayed in a table format.

Note
The detail parameter displays slightly different information depending on the platform and configuration you are working with.The link filter counter displayed with the detail parameter is calculated at the middle layer on receiving an event. The link filter up indicates the number of link transitions from down to up at the middle layer filter.
The following command displays port system-related information on a switch:
# show ports 25 information
ELSM/
Port Flags Link OAM/ Link Num Num Num Jumbo QOS Load
State MACsec UPS STP VLAN Proto Size profile Master
========================================================================================
25 Em---------fMB-S-x- active - / -/up 3 0 1 1 9216 none
========================================================================================
> indicates Port Display Name truncated past 8 characters
Flags : a - Load Sharing Algorithm address-based,
b - Rx and Tx Flow Control Enabled, B - Broadcast Flooding Enabled,
D - Port Disabled, e - Extreme Discovery Protocol Enabled,
E - Port Enabled, f - Unicast Flooding Enabled,
F - Priority Flow Control Enabled, G - MLAG Enabled, i - Isolation,
j - Jumbo Frame Enabled, l - Load Sharing Enabled,
L - Extreme Link Status Monitoring Enabled,
m - MACLearning Enabled, M - Multicast Flooding Enabled,
n - Ingress TOS Enabled, o - Dot1p Replacement Enabled,
O - Ethernet OAM Enabled, p - Load Sharing Algorithm port-based,
P - Software redundant port(Primary),
R - Software redundant port(Redundant),
s - diffserv Replacement Enabled, S - MACsec Enabled,
v - Vman Enabled, w - MACLearning Disabled with Forwarding,
x - Rx Flow Control Enabled
# show ports 25 information detail
Port: 25
Virtual-router: VR-Default
Type: UTP
Random Early drop: Unsupported
Admin state: Enabled with auto-speed sensing auto-duplex
MACsec Link State: Up
Link State: Active, 1Gbps, full-duplex
Link Ups: 3 Last: Fri Dec 08 16:26:55 2017
Link Downs: 1 Last: Fri Dec 08 16:18:12 2017
VLAN cfg:
Name: MACsec_1000, Internal Tag = 1000, MAC-limit = No-limit, Virtual router: VR-Default
STP cfg:
Protocol:
Name: MACsec_1000 Protocol: ANY Match all protocols.
Trunking: Load sharing is not enabled.
EDP: Disabled
EEE: Disabled
ELSM: Disabled
Ethernet OAM: Disabled
MACsec: Enabled
The following example displays the current status of non-Extreme optical devices:
The following output displays show port info detail that has port-specific tag.
The following example shows LRM/MACsec Adapter port state information (in bold):
# show ports 3 information detail
Port: 3
Virtual-router: VR-Default
Type: SF+_CX1m (Unsupported) (LRM/MACsec Adapter)
LRM/MACsec Adapter port state: Operational
Random Early drop: Unsupported
Admin state: Enabled with 10G full-duplex
Link State: Active, 10Gbps, full-duplex
Link Ups: 1 Last: Fri Aug 16 12:07:01 2019
Link Downs: 0 Last: --
VLAN cfg:
Name: Default, Internal Tag = 1, MAC-limit = No-limit, Virtual router: VR-Default
STP cfg:
s0(enable), Tag=(none), Mode=802.1D, State=FORWARDING
Protocol:
Name: Default Protocol: ANY Match all protocols.
Trunking: Load sharing is not enabled.
EDP: Enabled
ELSM: Disabled
Ethernet OAM: Disabled
MACsec: Disabled
Learning: Enabled
Link-Flap Detection: Disabled
Unicast Flooding: Enabled
Multicast Flooding: Enabled
Broadcast Flooding: Enabled
Jumbo: Disabled
Flow Control: Rx-Pause: Enabled Tx-Pause: Disabled
Priority Flow Control: Disabled
Reflective Relay: Disabled
Link up/down SNMP trap filter setting: Enabled
Egress Port Rate: No-limit
Broadcast Rate: No-limit
Multicast Rate: No-limit
Unknown Dest Mac Rate: No-limit
QoS Profile: None configured
Ingress Rate Shaping : Unsupported
Ingress IPTOS Examination: Disabled
Ingress 802.1p Examination: Enabled
Ingress 802.1p Inner Exam: Disabled
Ingress 802.1p Priority: 0
Egress IPTOS Replacement: Disabled
Egress 802.1p Replacement: Disabled
NetLogin: Disabled
NetLogin port mode: Port based VLANs
Smart redundancy: Enabled
Software redundant port: Disabled
IPFIX: Disabled Metering: Ingress, All Packets, All Traffic
IPv4 Flow Key Mask: SIP: 255.255.255.255 DIP: 255.255.255.255
IPv6 Flow Key Mask: SIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff
DIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff
Far-End-Fault-Indication: Disabled
Shared packet buffer: default
VMAN CEP egress filtering: Disabled
Isolation: Off
PTP Configured: Disabled
Time-Stamping Mode: None
Dynamic VLAN Uplink: Disabled
VM Tracking Dynamic VLANs: Disabled
The following command displays the indication that a 25G lane-based optic has been inserted into a port partitioned for 10G lanes (lines 4-5):
(pacman debug) switch-model-EXOS.6 # show port 25 information detail
Port: 25
Virtual-router: VR-Default
Type: Q28+SWDM4 (Mismatches Partition)
Random Early drop: Unsupported
Admin state: Enabled with 40G full-duplex
Link State: Ready
Link Ups: 0 Last: --
Link Downs: 0 Last: --
VLAN cfg:
Name: Default, Internal Tag = 1, MAC-limit = No-limit, Virtual router: VR-Default
STP cfg:
s0(enable), Tag=(none), Mode=802.1D, State=DISABLED
Protocol:
Name: Default Protocol: ANY Match all protocols.
Trunking: Load sharing is not enabled.
EDP: Enabled
ELSM: Disabled
Ethernet OAM: Disabled
MACsec: Disabled
Learning: Enabled
Link-Flap Detection: Disabled
Unicast Flooding: Enabled
Multicast Flooding: Enabled
Broadcast Flooding: Enabled
Jumbo: Disabled
Flow Control: Rx-Pause: Enabled Tx-Pause: Disabled
Priority Flow Control: Disabled
Reflective Relay: Disabled
Link up/down SNMP trap filter setting: Enabled
Egress Port Rate: No-limit
Broadcast Rate: No-limit
Multicast Rate: No-limit
Unknown Dest Mac Rate: No-limit
QoS Profile: None configured
Ingress Rate Shaping : Unsupported
Ingress IPTOS Examination: Disabled
Ingress 802.1p Examination: Enabled
Ingress 802.1p Inner Exam: Disabled
Ingress 802.1p Priority: 0
Egress IPTOS Replacement: Disabled
Egress 802.1p Replacement: Disabled
QOS Profile Settings: QP1 MinBw = 0% MaxBw = 100% MaxBuf = 100% Weight = 1
QP8 MinBw = 0% MaxBw = 100% MaxBuf = 100% Weight = 1
NetLogin: Disabled
NetLogin port mode: Port based VLANs
Smart redundancy: Enabled
Software redundant port: Disabled
IPFIX: Disabled Metering: Ingress, All Packets, All Traffic
IPv4 Flow Key Mask: SIP: 255.255.255.255 DIP: 255.255.255.255
IPv6 Flow Key Mask: SIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff
DIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff
Far-End-Fault-Indication: Disabled
Shared packet buffer: default
VMAN CEP egress filtering: Disabled
Isolation: Off
PTP Configured: Disabled
Time-Stamping Mode: None
Port Partition: 1x40G
Available Port Partitions: 1x40G, 4x10G, 2x50G, 4x25G
Dynamic VLAN Uplink: Disabled
VM Tracking Dynamic VLANs: Disabled
Forward-Error-Correction: Disabled
The following command displays the indication that a 100G optic has been inserted into an unlicensed port (lines 4-5):
(pacman debug) X870-32c.2 # show port 1 info detail
Port: 1
Virtual-router: VR-Default
Type: Q28+SWDM4 (Mismatches Partition) (Unlicensed)
Random Early drop: Unsupported
Admin state: Enabled with 10G full-duplex
Link State: Ready
Link Ups: 0 Last: --
Link Downs: 0 Last: --
VLAN cfg:
STP cfg:
Protocol:
Trunking: Load sharing is not enabled.
EDP: Enabled
ELSM: Disabled
Ethernet OAM: Disabled
MACsec: Disabled
Learning: Enabled
Link-Flap Detection: Disabled
Unicast Flooding: Enabled
Multicast Flooding: Enabled
Broadcast Flooding: Enabled
The following command displays port information with ingress filtering for MAC-based VLANs enabled:
# show ports 1:2 information detail
Port: 1:2
Virtual-router: VR-Default
Type: UTP
Random Early drop: Unsupported
Admin state: Enabled with auto-speed sensing auto-duplex
Link State: Ready
Link Ups: 0 Last: --
Link Downs: 0 Last: --
VLAN cfg:
Name: SYS_VLAN_0300, Internal Tag = 300(MAC-Based with ingress filtering on), MAC-limit = No-limit, Virtual router: VR-Default
Name: SYS_VLAN_0301, Internal Tag = 301(MAC-Based with ingress filtering on), MAC-limit = No-limit, Virtual router: VR-Default
Name: SYS_VLAN_0500, 802.1Q Tag = 500, MAC-limit = No-limit, Virtual router: VR-Default
Port-specific VLAN ID: 500
Name: SYS_VLAN_0501, 802.1Q Tag = 501, MAC-limit = No-limit, Virtual router: VR-Default
Port-specific VLAN ID: 501
STP cfg:
Protocol:
Name: SYS_VLAN_0301 Protocol: ANY Match all protocols.
Name: SYS_VLAN_0300 Protocol: ANY Match all protocols.
Trunking: Load sharing is not enabled.
EDP: Enabled
EEE: Disabled
ELSM: Disabled
Ethernet OAM: Disabled
MACsec: Disabled
Learning: Enabled
Link-Flap Detection: Disabled
Unicast Flooding: Enabled
Multicast Flooding: Enabled
Broadcast Flooding: Enabled
Jumbo: Disabled
Flow Control: Rx-Pause: Enabled Tx-Pause: Disabled
Priority Flow Control: Disabled
Reflective Relay: Disabled
Link up/down SNMP trap filter setting: Enabled
Egress Port Rate: No-limit
Broadcast Rate: No-limit
Multicast Rate: No-limit
Unknown Dest Mac Rate: No-limit
QoS Profile: None configured
Ingress Rate Shaping : Unsupported
Ingress IPTOS Examination: Disabled
Ingress 802.1p Examination: Enabled
Ingress 802.1p Inner Exam: Disabled
Ingress 802.1p Priority: 0
Egress IPTOS Replacement: Disabled
Egress 802.1p Replacement: Disabled
QOS Profile Settings: QP1 MinBw = 0% MaxBw = 100% MaxBuf = 100% Weight = 1
QP8 MinBw = 0% MaxBw = 100% MaxBuf = 100% Weight = 1
NetLogin: Disabled
NetLogin port mode: MAC based VLANs with ingress filtering on
Smart redundancy: Enabled
Software redundant port: Disabled
IPFIX: Disabled Metering: Ingress, All Packets, All Traffic
IPv4 Flow Key Mask: SIP: 255.255.255.255 DIP: 255.255.255.255
IPv6 Flow Key Mask: SIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff
DIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff
auto-polarity: Enabled
Shared packet buffer: default
VMAN CEP egress filtering: Disabled
Isolation: Off
PTP Configured: Disabled
Time-Stamping Mode: None
Dynamic VLAN Uplink: Disabled
VM Tracking Dynamic VLANs: Disabled
The following command displays port information for ports 23 and 24 with MDI and MDIX mode configured and auto-polarity disabled:
# show port 23 information detail | in polarity
auto-polarity: Disabled (MDI)
# show port 24 information detail | in polarity
auto-polarity: Disabled (MDIX)
This command was first available in ExtremeXOS 10.1.
Information on ingress rate shaping was added in ExtremeXOS 11.0.
Network Login, Smart Redundancy, and rate limiting were added in ExtremeXOS 11.1.
Information on unicast, multicast, and broadcast flooding; the Port not present parameter; and autopolarity status were added in ExtremeXOS 11.2.
The netlogin parameters were added in ExtremeXOS 11.3.
The output command was modified in ExtremeXOS 12.1 so that when learning is disabled with the disabled learning port command, a new w flag appears in the output.
Link Ups and Link Downs information was added to the output and the tag value was added to the command syntax in ExtremeXOS 12.4.4.
Industrial Temperature detail added to Type field in ExtremeXOS 15.1.2.

Note
The Industrial Temperature detail is only displayed only when detail is used. Without it, the output is compressed and the optic type is not displayed.The show output was enhanced to display the SNMP ifMib ifAlias accessible string size information.
Link-flap detection information was added in ExtremeXOS 22_1.
Available Port Partitions was added to show port speed licensing information for ExtremeSwitching X870-96x-8c switches in ExtremeXOS 22.2.
IEEE Forward Error Correction (FEC) Clause 74 or 91 modes status was added in ExtremeXOS 22.3.
MACsec flag (S) and LRM/MACsec adapter in the detail Type field was added in ExtremeXOS 30.1.
LRM/MACsec Adapter port state information was added in ExtremeXOS 30.4.
Mismatched port compatility indication was added in ExtremeXOS 31.3.
Ingress filtering for MAC-based VLANs was added in ExtremeXOS 31.5.
mdi-mode information was added in version 32.6.
This command is available on all Universal switches supported in this document.