show interfaces gigabitethernet limit-fdb-learning

Show the configuration for the limit forwarding database (FDB) learning feature.

Syntax

Command Parameters

{slot/port[/sub-port][-slot/port[/sub-port]][,...][slot/all][all]}

Identifies the slot and port in one of the following formats:

  • a single slot and port (slot/port)

  • a range of slots and ports (slot/port-slot/port)

  • a series of slots and ports (slot/port,slot/port,slot/port)

  • all ports on the same slot (slot/all)

  • all ports on the switch (all)

If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port.

<1-4059>

Specifies the VLAN ID in the range of 1 to 4059. By default, VLAN IDs 1 to 4059 are configurable and the system reserves VLAN IDs 4060 to 4094 for internal use. On switches that support the vrf-scaling and spbm-config-mode boot configuration flags, if you enable these flags, the system also reserves VLAN IDs 3500 to 3998. VLAN ID 1 is the default VLAN and you cannot create or delete VLAN ID 1.

Default

None

Command Mode

Privileged EXEC

Usage Guidelines

This command does not apply to all hardware platforms. For more information about feature support, see Fabric Engine and VOSS Feature Matrix.