Addressed Issues

Addressed Issues in release 25.14.0-76 lists Addressed Issues in ExtremeCloud IQ 25.14.0-76.

Table 1. Addressed Issues in release 25.14.0-76
Issue IDDescription
CFDs

CFD-14649

Addressed the issue where a delta configuration push failed with a rate-limit multicast error for an aggregated interface, and prevented further delta updates on the affected access point.

CFD-17067

Addressed the issue where NAC Profile and NAC Details did not populate for most clients in Client 360, even though ExtremeControl reported the corresponding end-system details.

CFD-17082

Addressed the issue where an inactive wireless device showed as a wired device on the connected switch port instead of retaining its last known access point association.

CFD-17244

Addressed the issue where certificate bundles created under Common Objects > Certificate Management for OpenRoaming were not persisted or validated correctly.

CFD-17388

Addressed the issue where the CSV file generated from Manage > Client monitor and diagnosis for a chosen timestamp did not include all events.

CFD-17501

Addressed the issue where an access point showed as offline in ExtremeCloud‌ IQ while its CAPWAP client status indicated a secure connection to the CAPWAP server.

CFD-17704

Addressed the issue where an AP4020 running IQ Engine 10.8.5.4 intermittently lost its CAPWAP connection.

CFD-17878

Addressed the issue where new AP3000 access points failed to onboard because they did not receive a country code, CAPWAP server IP address, or Hive Manager primary or backup name.

CFD-17912

Addressed the issue where rogue devices and clients detected by AirDefense Essentials could not be located using Location Essentials.

CFD-17996

Addressed the issue where access points showed as online but were unreachable during a bulk configuration push.

CFD-18103

Addressed the issue where toggling Additional Columns on and off in the Network Devices default view reset the customized column order.

CFD-18109

Addressed the issue where IP range classification rules in network policies could not extend beyond a single /24 subnet.

CFD-18110

Addressed the issue where running the Show IKE SA diagnostic under Utilities > Diagnostic did not complete.

CFD-18180

Addressed the issue where uploading a captive web portal (CWP) file under SSIDs returned a file named TRUE instead of the uploaded file.

CFD-18186

Addressed the issue where Cloud PPSK users could not authenticate for up to a few hours after creation.

CFD-18221

Addressed the issue where setting a port type to Trunk in a device template omitted the VLAN configuration, so all trunk ports used the default VLAN and could not be customized during port type configuration.

CFD-18233

Addressed the issue where exporting the kat_encryption_audit_log table failed with an internal error.

CFD-18271

Addressed the issue where saving an open SSID with an EGuest captive portal and a custom, non-default user profile reverted the profile to the default guest profile (VLAN 1).

CFD-18309

Addressed the issue where a timed-out account deletion prevented a customer from using the associated email address to register a new account.

CFD-18330

Addressed the issue where a duplicate portal account for a customer email address prevented the customer from being added as an administrator.
Account Management
XIQ-52932Addressed an issue where IDM gateway post-authentication logging timeouts caused valid Cloud PPSK authentication requests to fail with an Access-Reject.
API

XCP-26361

Addressed the issue where the cs-metaflow-telemetry-server and cs-metaflow-metrics-telemetry-server deployments remained in a degraded state.

XCP-26979

Addressed the issue where the cs-event-mvtx-highpriority and cs-metric-mvtx-highpriority applications remained in a degraded health state after deployment.
Device Management

XIQ-52258

Addressed the issue where an AP5022S6D configured for dual 6 GHz operating mode (6H/5/6L) included channels 97 through 125 in the 6H band for the Peru, Kazakhstan, Dominican Republic, and Brazil country codes.

XIQ-52259

Addressed the issue where the AP3020 applied an incorrect transmit power to the WiFi1 interface for the Italy country code.

XIQ-52263

Addressed the issue where SSID configuration on an AP3020 failed when the security mode was set to WPA with TKIP.
Logs

XIQ-52219

Addressed the issue where Supplemental CLI commands remained listed in the Delta Configuration Audit view after a Complete Update successfully applied them.
Upgrading
XCP-14211 Addressed the issue where the Firmware Version dropdown is not visible during a firmware upgrade when multiple APs are selected and the last device in the list is reviewed on high-resolution displays.

XCP-25227

Addressed the issue where the cs-perfmonitor-ingestion consumer group developed a lag after the an upgrade.

XIQ-52618

Addressed the issue where firmware upgrades did not run in ExtremeCloud IQ (Classic), even though the Extreme Platform ONE Networking Task History showed the upgrade as scheduled.
User Interface

XIQ-52350

Addressed the issue where an access point appeared twice on the Usage & Capacity view of the Network Devices page.