REVISION NOTES FOR BAYRS VERSION 13.02 REVISION 1
================================================================

Site Manager compatibility:
BayRS version is managed by Site Manager version
13.02 Revision 1 --------------------> 7.02 Revision 1

13.02 Revision 1 is Year 2000 Compliance Certified by Bay Networks. It has
successfully passed Bay Networks Test Procedure which tests conformance to Bay
Networks Year 2000 compliance definition, both of which can be found at Bay
Networks Year 2000 Web site at http://www.baynetworks.com/year2000/.

================================================================
13.02 Revision 1 corrects the following problems:
================================================================
CR 33348: SW Serv
Scheduling time of day (TOD) parameters for a demand circuit using
NOT_AVAILABLE causes the demand circuit to not come up after the end
time has passed.

CR 33863: TI
SAving the log automatically using the Technician Interface does not
work on Volume 1.

CR 33883: DSU/CSU
Analog loop does not work on the ARN internal DSU/CSU. The circuit
stays down and frames are not transmitted.

CR 34386: OSPF
OSPF is not generating a default summary route into a stub area to
which it is directly attached.

CR 35612: IP
Memory leak occurs on all slots with BGP configured.

CR 55832/98693: MIB
Network management applications, such as Optivity Expanded View,
do not display the 5380 Quad Sync and two compression net modules.

CR 71256: MCE1
When moving a logical line from one slot to another one in dynamic
mode, the IP circuit fails on a multichannel E1.

CR 72142: OSI
OSI adjacencies are not reestablished after an OSI point-to-point
circuit bounces.

CR 73835: ARE
The ARE may fail to boot if a FRE-II processor with flash memory is busy.

CR 75883: MCE1
The multichannel E1 interface is not fully compliant with MIB 2 RFC 1213.

CR 79479: TI
The show hardware script terminates abnormally if the router was booted
with the Technician Interface configuration file (ti.cfg).

CR 79920: MCE1
After loading the ASN and Munich drivers and setting the clocking to internal,
the CPU use on the router went up to 40 to 50 percent.

CR 80778: IPEX Gateway
When the PVC/TCP server application is closed, you cannot restart the session
after the application is brought back up.

CR 83316: BGP
Fault when changing BGP4 accept policy to add Route Flap Dampening.

CR 83929: Flash
When compacting or formatting a 40MB or larger flash card, the slot which
is formatting stops forwarding traffic and reboots after completing
compaction. In addition, frame relay circuits on that slot lose LMI and
any connections through it are dropped.

CR 83931: FTP
When making an FTP brute force attack, a bus error occurs on the router.
The software used to attack reports a buffer overflow problem.

CR 85315: X.25
Placing a call with IPEX disabled on an ARN router does not generate a
CLEAR CONFIRM, causing the X.25 pad to hang.

CR 85509: DLSw
Request for DLSw multislot broadcast for a MIB attribute to allow (default)
or disallow the cross slot updating of peer associations.

CR 88224: IP
Bus errors in IP upon boot are causing loss of connectivity.

CR 91568: IP
IP faults when a well-known denial of service packet arrives. Only
ISP Mode with enhanced traffic filters on the FRE2 is vulnerable.

CR 92038: ATM
Router faults with an MCP error upon receiving a LE_NARP request, which
has the MAC address equal to the ARE MAC address.

CR 93415: IP
When you are changing attributes associated with ATM PVCs, an MCP error
can occur on the ATM interface.

CR 94541: OSI
Enabling OSI on a router causes the router to immediately log the message
"Starting L2/L1 decision process" every few seconds.

CR 94618: IP
IP connectivity lost when configuring Host-Only mode on a BLN FDDI Link
Module.

CR 94886: ATM
Learning Bridge (LB) does not work across ATM hybrid PVCs.

CR 95125: X.25
When full addressing is set to Off, the router cannot establish X.25 PDN
calls.

CR 95185: FDDI
Faults occur in the FDDI driver when booting a BLN router with ATM configured.

CR 96270: PPP
Orphan buffers occur when transmitting SDLC I frames through DLS and PPP
multilink processed in WCP.

CR 96440: OSPF
The router fails to build the SPF tree if the root LSDB is not inserted into
router table.

CR 96646: SRB
Source Route Bridged spanning tree explorer frames are not received by the
router over an ATM PVC.

CR 96788: DLSw
When making a network connection to an IBM host for DLSw transactions, some
errors occur.

CR 97093: IP
Bus error on router with multiple IP configured slots.

CR 97288: X.25
If the target circuit is disabled, a reset_request is not sent when a tcp_open
call fails.

CR 97842: X.25
If the value of the X.25 parameter Outgoing Call Accept is set to OFF (the
default is ON) and if at least two X.25 service records have been defined over
the X.25 line, a bus error occurs as soon as the router needs to place an
outgoing call.

CR 98211: XB
When the wfBrTp MIB attribute is disabled and a router translation bridge
interface receives an ARE while the RIF (routing information field) entry is
still cached, a fault occurs.

CR 98424: DLSw
Deleting the last DLSw interface on a slot using the BCC causes a system
error.

CR 98691: SWSERV
The schedule function is not working correctly during NOT_AVAILABLE period.

CR 98693/55832: MIB
Network management applications, such as Optivity Expanded View, do
not display the 5380 Quad Sync and two compression net modules.

CR 98719: IP
When a FDDI connection is faulted, RIP1 will not advertise the network
as being unreachable before removing it.

CR 98938: OSPF
When you summarize a network of 0.0.0.0/0.0.0.0 in a backbone area going
to all other areas, the router sends out a link state database (LSDB) message
that says that this database has a timer of 3600 (unreachable) so it is never
put in the LSDB.

CR 98902: ATM
When the MIB is being queried for certain objects when the atmizer is coming
up (for example, after a dynamic reconfiguration) the MIB Manager will time
out.

CR 98930: SDLC
Disabling or deleting multiple devices from an SDLC--multidrop of a primary
frame relay access device (FRAD) occasionally causes the secondary FRAD to
fault.

CR 99148: IP
Static route preferences do not work over properly unnumbered circuits on
router when there is an unnumbered interface on one side of a PPP interface
and a numbered one on the other side.

CR 99295: PPP
The router will fault after IPCP negotiations.

CR 99607: ATM
When an outage occurs that brings down the ATM interface, it never comes back
up without physically pulling the fiber connection.

CR 99870: BGP
Forwarding 56k routes to another BGP speaker takes about 17 minutes.

CR 99887: IP
The forwarding cache of an IP interface gets corrupted when it switches from a
more specific route to a less specific route.

CR 99914: BGP
BGP learned routes not propagated into OSPF domain.

CR 100000: ATM
Sending large packets through an ATM PVC that is over utilized and clipping
frames on transmit causes VBM panics.

CR 100208: Telnet
Arrow keys do not work when you Telnet to the router and then run Telnet
client to another device.

CR 100352: FR
Frame relay PVC status not correctly reflected in the wfIfEntry MIB and
consequently the ifEntry instance.

CR 100377: ATM
When creating or deleting virtual circuits on a BCN router, a MCP (Master
Control Processor) error occurs on the ATM interface, and communication
between routers is lost.

CR 100556: ATM
Router does not respond or challenge an LE_NARP request for its interface
MAC address.

CR 100791: BGP
When a BCN router has an external peer supplying multi exit discriminator
(MED) to it and the router is configured to be a route reflector (RR) internal
to another peer, and there is no policy to advertise MEDs to that internal
peer, the router takes a long time to download all the routes to that peer.

CR 100914: X.25
When TCP is in a closed state, the MIB for IPEX Session Local TCP Port does
not get reset and displays an incorrect value.

CR 101058: ATM
When deleting the connection port to a FORE switch on the router, a tag
violation occurs.

CR 101124: ATM
Using the BCC to delete a Multi-Protocol Over ATM (MPOA) service generates MCP
errors.

CR 101125: ATM
The ATM interface remains in the initial state when the link between the Bay
Networks BCN router and FORE switch is repeatedly broken.

CR 102020: BOT
If the serial link is operating at 2400 baud and the router adds synchronous
characters between the two bytes of BCC error checking frames, the end device
miscalculates the BCC causing a negative acknowledgment (NAK).

CR 102070: XB
Duplicated frames are transmitted after the LB (Learning Bridge) is started
globally or on an interface.

CR 102109: X.25
If several packets are received by a router simultaneously and they are all
destined for the same remote X.25 PDN site, extra VCs are created. The extra
VCs do not come up, which can result in data loss.

CR 102114: ATM
When adding ATM service records and or PVCs while passing traffic, the ATM
interface experiences a MCP (Master Control Processor) error.

CR 102122: ATM
A VBM (virtual buffer memory) error may occur on the ATM interface under a
heavy traffic load.

CR 102424: SYNC
The ARN router may hang after establishing a V.34 asynchronous dialup
connection.

CR 102626: ARP
A LAN interface receiving ARP traffic in a switched environment causing a 30%
to 50% load on the router CPU can result in extra memory buffer depletion.

CR 102776: SWSERV
Dial backup line connection is not going down after the primary frame relay
line recovers its connection on the router.

CR 102209: X.25
The slot on BCN faults and resets during multiple connections and tear downs.
During multiple X.25 connection calls and disconnects, the router may fault.

CR 102809: Data Path
Cannot multiline more than three X.25 PDN VCs at a time.

CR 102835: IP
Sending large packets that result in fragmentation of the ping packet causes a
bus error on the router.

CR 103371: ATM
All of the LECs do not recover when the link between the FORE switches is
broken.

CR 103656: BCC
Sourcing the diff file using the BCC host tools on the router generates the
following error message, "attempt to add duplicate list entry."

CR 104168: ATM
ATM Interface does not recover after the port on the FORE switch is deleted
and later readded in a configuration with multiple LECs are configured to join
multiple ELANs on the FORE switch.

CR 104246: ATM
The LE_ARP entry in the wfAtmLeArpEntry may point to a non-existent
or released VC entry in the wfAtmVclConfEntry due to a timing issue.

CR 105235: X.25
Bouncing Logical Line Entry between X.25 and IPEX may result in some connections not recovering.

CR 105523: ATM
The router generates an exception Vector 3 machine check (MCP) fault during an ATM test.

CR 105577: Data Path
Toggling a primary circuit and a backup circuit causes an Exception Vector 2
bus error.

CR 106453: IPX
Virtual Network Router (VNR) 5782 configured for IPX stops transmitting timed RIP updates.