================================================================ REVISION NOTES FOR BAYRS VERSION 13.03 REVISION 1 ================================================================ Site Manager compatibility: BayRS version is managed by Site Manager version 13.03 Revision 1 --------------------> 7.03 and 7.03 Revision 1 13.03 Revision 1 is Year 2000 Compliance Certified by Nortel Networks. It has successfully passed Nortel Networks Test Procedure which tests conformance to the Nortel Networks Year 2000 compliance definition, which can be found at the Nortel Networks Year 2000 Web Site at http://www.nortelnetworks.com/corporate/year2000/. ================================================================ 13.03 Revision 1 corrects the following problems: ================================================================ CR 32268: X.25 A X.25/PDN configuration cannot forward IP datagrams larger than 1915 bytes. CR 30736: XB A bus error occurs on the router when XB is configured dynamically on a slot that has both PPP a Wellfleet Standard configured. CR 34693: ATM An error occurs when running ATM with LAN Emulation configured. CR 85990: OSPF A more specific type 2 external LSA is incorrectly announced to the LSDB on an ASBR when there is a policy present to aggregate RIP learned routes. CR 86073: OSPF Type1 AS external LSAs are being installed into the routing table with the metric incorrectly calculated as a type 2 AS external LSAs. CR 87367: IPEX The router may fault when resetting many (greater than 100) IPEX sessions. CR 87801: CSMACD When a 100Base-T Ethernet interface is down or disabled it does not appear in the MIB II ifTable. CR 87829: PPP A bus error occurs on the router after a successful CHAP authentication on a leased line. CR 88495: X.25 When you configure a small number of virtual circuits when starting X.25, an insufficient quantity of PDU buffers is made available. CR 89524: IPX A VBM error occurs on the ATM slot when deleting IPX from an Ethernet circuit that is under load. CR 96282: IP When an interface is deleted using the BCC, the show ip routes command incorrectly shows the direct route of the deleted interface. CR 100921: RADIUS An enhancement request to provide unique session IDs for each accounting session logged by a RADIUS server. This is important because session ID, and not the client name, is used as the sole identifier by some applications. CR 101568: PPP When the IP interface of a Cisco router is shut down in a multilink with a Nortel Networks router, the Nortel Networks router shows extra lines when it is reenabled. CR 102358: DLSw The router does not establish a connection with SDLC RFC 1795 due to SDLC maximum data size being hard coded to 512 bytes. When this occurs the host receives the test poll with the small LF, it then sends an XID with a maximum I-frame bits also set to 516 bytes and the XID negotiation fails. CR 102314: IPX IPX unicast traffic with 802.2 encapsulation is not forwarded over a multiline circuit configured for Wellfleet Standard. CR 102838: PPP A bus error occurs on the router during start up of a NetBIOS session while using SR/DLSw on the local TR interfaces with ISDN/BRI with MLPPP and WCP enabled, plus an outgoing traffic filter (log or NoCall/NoReset for OSPF or RIP). CR 103164: DLSw When DLS receives an XID Fmt 3 frame from LLC for an active DLS connection, the router generates a CANUREACH SSP message for the source/destination MAC and SAPs rather than sending XID through directly. CR 103745: BGP BGP does not use the IGP cost to determine the next-hop address as the MED value of routes advertised to an EBGP peer. CR 104516: ATM Adding ATM PVCs under traffic load causes an MCP fault to occur. CR 105010: IP 5782 VNR stops sending IP RIP updates on various circuits. CR 106374: SDLC Bouncing TCP on a SDLC PU2.1 client to a token ring host with DLSw v2.0 causes an orphaned buffer fault to occur. CR 106710: Spanning tree A request to remove an invalid spanning tree debug log message. CR 106735: IPEX IPEX/X.25 slot intermittently faults and resets during multiple call attempts and teardowns. CR 106826: BGP The EBGP router does not port BGP routes to RIP when configured to do so. CR 107503: Telnet If a Telnet session dies while a batch file is running, a VBM error occurs on the slot running the ARE card. CR 107515: TCP When connecting to a circuitless IP address of a router using TCP, the router sets the TCP maximum segment size to 65501 which is not compliant with RFC 879. CR 100706: BGP Withdrawing 50000+ routes in a looped topology can cause a watchdog error to occur. CR 107806: LLC The router does not respond to SABMEs with a UA (unnumbered acknowledgment) packet which prevents DLSw traffic. CR 107829: OSPF In the link state database, the cost of an OSPF route to an aggregated group of networks is represented as the closest network interface. According to RFC 2328, the cost should instead be the distance to the furthest network out of the group of networks aggregated together. The new MIB attribute, wfOspfAggrUseMaxCost, allows you to determine whether to use the maximum or minimum route cost. By setting this attribute to 1, you can enable the OSPF route cost to represent the distance to the furthest network in the aggregated group. Otherwise, accept the default, 2 (Disable), for the OSPF cost to represent the closest network in the group. CR 108091: DVMRP Data can be lost when the router learns a subordinate route from one neighbor router and receives a poison reverse from another router that resides in its neighbor list. CR 108190: IP When a buffer overflow condition occurs on a Fast Ethernet interface, the wfCSMACDOfloRx counter is not incremented. CR 108279: IP A bad IP header checksum is generated when the Record Route option is used. CR 108690: ATM When an ATM circuit is deleted from a router where the cable is disconnected, the ifEntry incorrectly continues to show the interface as active. CR 108715: ATM An MCP fault occurs on the router if an ATM service record is deleted while the ARE is disconnected from the switch. CR 109232: IPX An IPX interface over PPP may not come up properly when a dial backup line is activated. CR 109399: ATM Half Bridge When a packet contains the data whose length is less than the minimum required for Ethernet encapsulation, ATM half bridge does not pad the data to the minimum length. CR 109636: MOSPF Invoking the show mospf fwd command causes a bus error to occur on the router when there are more than 20 IGMP join entries. CR 109640: MOSPF Invoking the show mospf fwd command does not show more than 13 downstream forwarding entries. CR 109873: TI-RUI Invoking the save log command through SNMP does not complete successfully and can cause a fault. CR 109909: Boot Booting the router multiple times with either a named boot file or typing boot causes orphan buffers in the log. Also, any router slots that do not contain a flash card will stop loading protocols. CR 109933: BGP Invoking the ip bgp_routes -N command only displays the first four peers correctly. CR 110036: ATM The router LEC is using the wrong parameters when placing control of direct VCC to LES. CR 110168: ATM Traffic origination from an 802.5 LEC with source route bridging does not establish a data direct virtual circuit. CR 110427: Filters Invoking the show ip traffic filter command in the Technician Interface displays incorrect information for the traffic filter fragments associated with the wfIPTrafficFilterEntry MIB. CR 110491: NAT Moving the NAT soloist to another slot fails to update wfNatMapEntry on the new soloist slot which causes a loss of connectivity. CR 110783: ATM The LEC is responding to LE_ARP requests for LAN destinations that it does not represent. CR 111197: BGP With the BGP soloist running on an FRE-4 and with a flash card on another slot, the router faults whenever BGP attempts to open the TCP connection to the remote site. CR 111507: BGP BGP peers are getting stuck in the Not Present state where they appear in the idle state at one end, and in the connected state at the other end. CR 111562: AHB Adding a PVC under load causes an MCP error to occur on the ARE module. CR 112106: MOSPF The BCN router crashes when the number of MOSPF forwarding entries exceeds 251. CR 112535: IP After booting up or bouncing IP on a fully loaded router, directly connected hosts may become unreachable from remote slots. |