REVISION NOTES FOR SITE MANAGER VERSION 7.02 REVISION 1
===================================================================

Site Manager Version 7.02 Revision 1 is a post 5.00 revision. This version is
backwards compatible and supports the following BayRS (router software)
versions:

    13.02
    13.01
    13.00
    12.03
    12.02
    12.01
    11.03
    11.02
    11.01
    11.00

Note: When running revisions of BayRS in conjunction with a fix version of
Site Manager, be aware that there may be new MIB attributes that were added in
a router revision that are not supported in a Site Manager revision. Refer to
the Revision Notes for both Site Manager and BayRS software.

7.02 Revision 1 is Year 2000 Compliance Certified by Bay Networks. It has
successfully passed Bay Networks Test Procedure which tests conformance to Bay
Networks Year 2000 compliance definition, both of which can be found at Bay
Networks Year 2000 Web site at http://www.baynetworks.com/year2000/.

===================================================================
7.02 Revision 1 corrects the following problems:
===================================================================

CR 24449: DECnet
Site Manager allows user to dynamically set the global DECnet parameter
Max Area to be lower than the highest configured areas.

CR 26224: IP
Site Manager does not allow you to change an IP address when editing a
circuit. The following error message is displayed even when multiple IP
interfaces are properly configured on the router:

"A single IP interface is currently configured. Multiple IP interfaces must
be configured to perform the change operation"

CR 30151: SWSERV
After dynamically deleting a demand pool using Site Manager, an instance of
the object wfModemEntry is not deleted.

CR 32476: DLSw
When configuring DLSw on a token ring interface:

1) If you add DLSw to the second, third or fourth token interface on a slot,
the Slot IP address should not pop up or it should be greyed out.

2) If DLSw is already configured on a token ring interface, and you add DLSw
to another token interface on that slot, if Source Route Bridging has already
been configured on the interface, no screens should pop up.

CR 83214: Events Manager
Event viewer filters not working properly for local log in Site Manager.

CR 86559: MOSPF
Circuitless IP interfaces on an OSPF router should only be set to Blocked for
multicast forwarding interfaces.

CR 93470: IGMP
When deleting DVMRP from the circuit using Site Manager, IGMP is also deleted
from the circuit.

CR 93788: PPP
When configuring HSSI, you are able to set the Bandwidth Allocation
percentages to total other than 100%.

CR 94906: Protocol Priority
When configuring an outbound filter template (Protocol Priority) Site Manager
produces an erroneous message "Minimum value greater than maximum value!" when
the minimum field contains a value less than the maximum field.

CR 96379: Config
Updated window titles from "Bay Networks" to "Nortel Networks."

CR 97381: X.25
The X.25 Call User Data (CUD) field does not accept all possible/needed hex
values.

CR 97682: DLSw
When adding DLSw to a token ring interface, Site Manager does not properly
configure the DLSw global parameters LAN ID, Bridge ID, and does not configure
DLSw interface LAN ID. If these values are not properly set, DLSw sends data
with incorrect RIF information and DLSw is unable to form a connection.

CR 98174: File Manager
Site Manager does not allow you to save file names that contain numbers.

CR 98289: ATM
Emulated LAN Segment ID does not show up when opened in Site Manager.

CR 98525: DLSw
A DLSw Slot IP address gets reset just by viewing it using Site Manager for
Windows.

CR 98917: IP
Using Site Manager to configure an existing ATM service record, Router
Discovery can either not be deleted (if it was added when the service record
was created) or cannot be added (if it was initially not added when the
service record was created).

CR 99801: SMDS
When configuring SMDS on a Fractional T1 module using the IP Interface screen,
Site Manager does not allow you to configure the SMDS Group Address or the
SMDS Arp Request Address.

CR 100499: Protocol priority
Protocol Priority disappears in Site Manager when adding protocols to a PVC
that has been moved from one service record to another.

CR 100531: ATM
After adding a PVC to a PVC service record and changing the PCR and
subsequently changing the SCR to 0 an MCP error occurs on the ARE.

CR 100955: IP
When adding an adjacent host, the following incorrect error message appears:
A Local IP Interface cannot be on same Subnet as Adjacent Host.

The message should say: An Adjacent Host must be on the same Subnet as the
local IP Interface.

CR 101531: SRB
After configuring a circuit for DLSw, the Source Route Global window does not
display when adding source routing on a different circuit.

CR 101675: SNMP
Using Report Generator on a router configured with the BOT (Binary Synchronous
Communication over TCP/IP) feature produces garbled text in the Line Mapping
Entry table (wfLineMappingEntry.4).

CR 101783: Compression
When configuring a WAN interface for frame relay or PPP with WCP in local mode
on a BCN or BLN that has a FRE2-060E/Advanced Compression Co-Processor
Daughter Board, Site Manager will not allow "Hardware" as the engine type with
QMCT1 in local or remote mode.

CR 102056: SNMP
On a router running Site Manager for Windows, if you connect to the router
with a read-write community string and try to edit the configuration file
dynamically, a dialog box warns you that the SNMP Community is read only and
you cannot edit the file.

CR 102541: Frame relay
Using Site Manager to add DLCIs to a frame relay circuit on a router running
BayRS 11.0x code causes an SNMP set error.

CR 102868: ATM
When deleting an ATM PVC service record, Site Manager performs two MIB sets
which causes a variety of router faults.

CR 103019: Frame relay
In the Frame Relay PVC List for Service window, Site Manager sets the Circuit
State Set to Active when it should be Inactive.

CR 103197: SRB
After adding source route bridging (SRB) to an ATM PVC and then looking at the
SRB global attributes there is no window title for the Global attributes. If
you go back to the "Configuration Manager" window and select Protocols ->
Source Routing -> Global, the window that pops up has a title of "Edit Source
Routing Global Parameters."