Revision Notes for Site Manager
Version 5.03/Revision 1

 

Site Manager Revision 5.03/Revision 1 is a post 5.00 revision. This version 
is backwards compatible and supports the following router versions:
      11.03
      11.02
      11.01
      11.00
      10.01
      10.0
            
Note: When running revisions of router software in conjunction with
a fix version of Site Manager, be aware that there may be new MIB
attributes that were added in a router revision that are not supported
in a Site Manager revision. Refer to the revision notes for both Site
Manager and router software.
 
=============================================================================
5.03 Revision 1 corrects the following problems:
=============================================================================
CR 72781: FireWall.
          The FireWall product was introduced in 11.02/Rev 2. When you use
          Site Manager to connect to a router that is running a release
          earlier than 11.02/Rev 2, the FireWall menu should be unavailable.
CR 35899: BGP.
          When you create a BGP peer to a circuitless IP address, invalid and/
          or multiple instances of wfCircuitNameEntry are created.
CR 35692: SNMP.
          When running Configuration Manager in dynamic mode, the wfProtocols
          MIB gets set to the value to which it is already set. The set does
          not affect service.
CR 35936: IP.
          When you use a circuitless IP address with an instance number of 1
          (under wfCircuitNameEntry), Site Manager can cause the router to
          unload and reload certain protocols.
CR 35797: BGP.
          Although the "Multi hop EBGP connection" parameter is set to
          enabled, you cannot configure BGP peers that are not on the same
          subnet.
CR 34872: PPP.
          SYNC MTU must be at least 56 bytes greater than PPP MRU.
CR 34913: Source Route Bridge.
          After you configure source route bridge on a dial on demand
          circuit, the source route interface window displays zeroes in all
          fields for that circuit.
CR 35142: OSPF.
          When you change any field in the "Edit OSPF Global Parameters"
          window, Site Manager resets the slot mask, causing OSPF to recycle. 
CR 35251: Site Manager.
          Defaults for MIBs are read from cdl-generated ASCII output files.
          Default values for MIBs of type GAUGE are represented as signed
          numbers. Site Manager reads type INTEGER values as long
          unsigned numbers.
CR 35354: PPP.
          For a dial backup circuit, if you enable the "RFC1661 Compliance"
          field in the "PPP Line List" window, wfSwservOptsRfc1661Compliance
          must be set to the same value as wfPppLineRfc1661Compliance
          internally.
CR 30180: IP.
          When you list the Announce Policy Filters, Site Manager duplicates
          the entries.
CR 33513: Events Manager.
          The events log displays the incorrect date for any year before the
          leap year.
CR 34951: Static Routes.
          If you attempt to configure a subnetted static route, such as
          12.12.12.0/255.255.255.0 or 192.32.37.0/255.25.255.240, Site Manager
          displays the message "IP Address/Subnet Mask are misconfigured" and
          does not add the route. Site Manager does allow you to add networks
          with a natural mask, such as 12.0.0.0/255.0.0.0. 
CR 35580: LLC2 traffic filters        
          Site Manager lets you create LLC2 traffic filters under the wrong
          circuit number. If you create an LLC2 traffic filter by selecting
          LLC Circuit > LLC2 Circuit and then Protocols > LLC2 Traffic
          filters, the filter will not work because Site Manager uses a
          circuit number that is different from the number assigned to
          this interface.
 
CR 33829: Logical Lines.
          If you UNSELECT the MCT card from the "Add Circuit" window, Site
          Manager does not allow you to re-select it.
CR 35348: Router Redundancy.
          Clicking on "Edit Lines" for ethernet and 100Base-T router redundant
          interfaces brings up the 100Mb/s CSMA/CD parameters window, which is
          incorrect. Site Manager should bring up the Edit CSMA/CD
          parameters window. If you click on OK, Site Manager displays the
          following message: "ERROR: Invalid data entered for Interface Line
          Speed". To exit the window, you must click on Cancel or enter an
          incorrect value for line speed.
          


 