| ============================================================================= REVISION NOTES FOR SITE MANAGER VERSION 6.05 REVISION 1 ============================================================================= Site Manager Version 6.05 Revision 1 is a post 5.00 revision. This version is backwards compatible and supports the following BayRS (router software) versions: 12.05 12.04 12.03 12.02 12.01 11.03 11.02 11.01 11.00 Note: When running revisions of BayRS in conjunction with a fix version of Site Manager, be aware that there may be new MIB attributes that were added in a router revision that are not supported in a Site Manager revision. Refer to the Revision Notes for both Site Manager and BayRS software. 6.05 Revision 1 is Year 2000 Compliance Certified by Nortel Networks. It has successfully passed Nortel Networks Test Procedure which tests conformance to Nortel Networks Year 2000 compliance definition, both of which can be found at Nortel Networks Year 2000 Web site at http://www.nortelnetworks.com/corporate/ year2000/. =================================================================== 6.05 Revision 1 corrects the following problems: =================================================================== CR 74482: QMCT1
Deleting a QMCT1 link module port using the Configuration Manager
in Dynamic mode does not remove its wfDs1E1PortEntry instance.
CR 80561: TFTP
Executing large numbers of TFTP transfers on a PC can cause general
protection faults to occur.
CR 91577: IP
There is a compatibility problem with Site Manager on HP/UX 10.20
with the X/Motif 1.2 Libraries Y2K patch (PHSS_13113, PHSS_14040,
and PHSS_16120). When you use Events -> Load Local Log Files, the
message "Log Browser module completed abnormally (E1701)"
incorrectly displays. Also, when you choose router types in a local
file configuration, the window color obscures the clear display of
router types.
CR 97013: SNMP
The color mapping at the LAN and WAN Protocols Selection windows in
Site Manager/HP_UX obscures the display, making the windows
illegible.
CR 105902: ASN2
The ASN2 router restarts during a boot because it cannot locate the
wfHwCfgEntry entry when it is not the first entry in the
hardware.ldb file.
CR 105944: SNMP
Site Manager does not display Technician Interface traps sent by
the router in the Trap Monitor window.
CR 106708: Spanning Tree
Spanning tree root selection fails with either SRB or LB spanning
tree configured on a null encapsulated ATM PVC service record.
CR 106858: DLSw
Able to configure backup peer parameters with Backup Config option
set to disabled.
CR 106866: IP
Attempts to change an IP interface address that has multiple
criteria traffic filters can cause Configuration Manager to fault
and terminate with no error message. This only occurs during
attempts to change the first IP instance.
CR 107046: IP
In Site Manager, selecting Protocols > IP > Interfaces > Change to
change the address on an interface, the change is not carried
through to the Associated Address for an IP Unnumbered Interface.
CR 107359: IP
Using the rename option in File Manager to execute a TFTP file
transfer from the router to the local machine can cause a
duplication of the files transferred.
CR 107591: Event Manager
Typing a file name without the associated path while saving a log
in Event Manager can cause a core dump to occur.
CR 107606: ATM
Solaris/Site Manager can freeze up when deleting an active ATM
circuit.
CR 107816: Report Generator
A core dump can occur in Site Manager when you generate reports in
Report Generator using template files.
CR 108254: Image Builder
Attempts to select a directory by typing the complete path are
unsuccessful when you use the file Open or Save options in Image
Builder.
CR 109260: BGP
When you try to delete BGP on an interface using Site Manager, only
the Add Circuit option is highlighted under Circuits in the
Configuration Manager even if multiple circuits exist.
CR 109261: Events Manager
Site Manager running on an HP/UX platform does not successfully
save output to disk when configuring within Events Manager.
CR 109975: ATM
When an ATM ARE circuit is created on an BCN/BLN and run in Report
Generator, the Site Manager Line Mapping entry table shows corrupt
data.
CR 110436: ATM
Under Token-Ring LANE there is no option to set the maximum frame
size, although this capability exists in the MIB and using the BCC.
|
Copyright © & SEC Notice
, 1998, Nortel Networks,Inc. All rights reserved.