Connecting Network Interface Cables

Use the appropriate type of cable to connect the ports of your switch to another switch or router.

For connections to the 10GBASE-T ports on the Summit X650-24t switch, see the following table for cable types and distances.

Cable Type Maximum Distance
CAT5E 55 meters
CAT6 55 meters
CAT6A 100 meters
Note

Note

Cables used for connection to the 10GBASE-T ports on the Summit X650-24t switch must meet the minimum requirements of the IEEE 802.3an standard.

Working carefully, one port at a time, do the following:

  1. Verify that you have identified the correct cable for the port.
  2. Use an alcohol wipe or other appropriate cleaning agent to clean the cable connectors; make sure they are free of dust, oil, and other contaminants.
  3. If you are using optical fiber cable, align the transmit (Tx) and receive (Rx) connectors with the correct corresponding connectors on the switch or the I/O module.
  4. Press the cable connectors into their mating connectors on the switch or I/O module until the cable connector is firmly seated.
  5. Repeat step 1 through step 4 for the remaining cables on this or other switches or I/O modules.
  6. Dress and secure the cable bundle to provide appropriate strain relief and protection against bends and kinks.
Set up local management access, and configure the switch's software, by following the instructions in Performing Initial Management Tasks.