mefSoamPmThresholdCrossingAlarm

Description

An mefSoamPmThresholdCrossingAlarm notification is sent if the following conditions are met for a particular type.

For an aboveAlarm five conditions need to be met:

a) measurement of the parameter is enabled via mefSoamLmCfgMeasurementEnable for a LM crossing or mefSoamDmCfgMeasurementEnable for a DM crossing; and

b) the parameter threshold is configured in the mefSoamLmThresholdCfgTable or mefSoamDmThresholdCfgTable; and

c) the threshold crossing type of bPmThresholdAboveAlarm is enabled; and

d) the measured value of the parameter exceeds the value configured in the mefSoamLmThresholdCfgTable for a LM crossing entry or mefSoamDmThresholdCfgTable for a DM crossing entry for a type of bPmThresholdAboveAlarm; and

e) no previous mefSoamPmThresholdCrossingAlarm notifications with type aboveAlarm have been sent relating to the same threshold in the mefSoamLmThresholdCfgTable or mefSoamDmThresholdCfgTable and the same parameter, during this Measurement Interval.

For a setAlarm five conditions need to be met:

a) measurement of the parameter is enabled via mefSoamLmCfgMeasurementEnable for a LM crossing or mefSoamDmCfgMeasurementEnable for a DM crossing; and

b) the parameter threshold is configured in the mefSoamLmThresholdCfgTable or mefSoamDmThresholdCfgTable; and

c) the threshold crossing type of bPmThresholdSetClearAlarm is enabled; and

d) the measured value of the parameter exceeds the value configured in the mefSoamLmThresholdCfgTable for a LM crossing entry or mefSoamDmThresholdCfgTable for a DM crossing entry for a type of bPmThresholdSetClearAlarm for the Measurement Interval; and

e) the previous measured value did not exceed the value configured in the mefSoamLmThresholdCfgTable for a LM crossing entry or mefSoamDmThresholdCfgTable for a DM crossing entry for a type of bPmThresholdSetClearAlarm.

For a clearAlarm five conditions need to be met:

a) measurement of the parameter is enabled via mefSoamLmCfgMeasurementEnable for a LM crossing or mefSoamDmCfgMeasurementEnable for a DM crossing; and

b) the parameter threshold is configured in the mefSoamLmThresholdCfgTable or mefSoamDmThresholdCfgTable; and

c) the threshold crossing type of bPmThresholdSetClearAlarm is enabled; and

d) the measured value of the parameter did not exceed the value configured in the mefSoamLmThresholdCfgTable for a LM crossing entry or mefSoamDmThresholdCfgTable for a DM crossing entry for a type of bPmThresholdSetClearAlarm for the Measurement Interval; and

e) the previous measured value did exceed the value configured in the mefSoamLmThresholdCfgTable for a LM crossing entry or mefSoamDmThresholdCfgTable for a DM crossing entry for a type of bPmThresholdSetClearAlarm.

In the case of thresholds applied to a maximum or average measurement counter, the previous measured value is the value of the counter at the end of the preceding Measurement Interval. In the case of thresholds applied to the last measured value, it is the previous measured value.

The management entity that receives the notification can identify the system from the network source address of the notification, and can identify the LM or DM session reporting the threshold crossing by the indices in the mefSoamPmNotificationCfgThresholdId object, including dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier, and the mefSoamLmCfgIndex or mefSoamDmCfgIndex.

An agent is not to generate more than one mefSoamLmThresholdCrossingAlarm 'notification-event' of a given type per LM or DM session as specified by mefSoamPmNotificationCfgAlarmInterval. A 'notification-event' is the transmission of a single notification to a list of notification destinations.

If additional threshold crossing events occur within the mefSoamPmNotificationCfgAlarmInterval period, then notification generation for these changes are suppressed by the agent until the current alarm interval expires. At the end of an alarm interval period, one notification-event is generated if any threshold crossing events occurred since the start of the alarm interval period. In such a case, another alarm interval period is started right away.

Object ID

1.3.6.1.4.1.15007.1.3.0.4

Trap    : mefSoamPmThresholdCrossingAlarm
Objects : {  mefSoamPmNotificationObjCrossingType, mefSoamPmNotificationObjThresholdId, mefSoamPmNotificationObjThresholdConfig, mefSoamPmNotificationObjThresholdValue, mefSoamPmNotificationObjSuspect, mefSoamPmNotificationObjDateAndTime, mefSoamPmNotificationObjDestinationMep }
OID     : "1.3.6.1.4.1.15007.1.3.0.4"
object  : mefSoamPmNotificationObjDestinationMep  type : MacAddress 
object  : mefSoamPmNotificationObjDateAndTime     type : DateAndTime 
object  : mefSoamPmNotificationObjSuspect         type : TruthValue 
object  : mefSoamPmNotificationObjThresholdValue  type : Unsigned32 
object  : mefSoamPmNotificationObjThresholdConfig type : Unsigned32 
object  : mefSoamPmNotificationObjThresholdId     type : ObjectID 
object  : mefSoamPmNotificationObjCrossingType    type : INTEGER