Resolved Issues in ExtremeXOS 16.1.3-Patch1-2

The following issues were resolved in ExtremeXOS 16.1.3-Patch1-2. ExtremeXOS 16.1.3-Patch1-2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, and ExtremeXOS 16.1.3. For information about those fixes, see the release notes for the specific release.

expand icon

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs)

CR Number Release Note
General
xos0057785 STP domain tag is removed when all ports are deleted from STP auto-bind enabled-VLANs.
xos0061745 Ampersand used in UPM script is replaced by “& amp” in the XSF configuration.
xos0062850 When upgrading ExtremeXOS to 15.7 or later releases, the web HTTP access is enabled even though it is disabled in the configuration.
xos0063134 Traffic stops after disabling, and then enabling LAG porst having pstag with static FDB.
xos0063173 Process dcbgp ends unexpectedly with signal 11 after issuing the command show bgp neighbor.
xos0063186 Kernel oops occurs when deleting private VLAN.
xos0063240 ACL process ends unexpectedly when switch has clear-flow ACL rule with count interval greater than snmptrap generation timer.
xos0063245 With IGMP per-VLAN mode, VRRP flaps occur after adding tagged ports to VLANs.
xos0063258 OSPFv3 routes are not updated in routing tables if there is a delay in receiving LSAs.
xos0063282 ExtremeXOS CLI restricts PVLAN subscriber VLAN from being configured as an EAPS-protected VLAN.
xos0063418 "No mapping for Modid" errors occur when sFlow is enabled on the port.
xos0063423 Memory leak occurs in ISIS process when exporting OSPF routes to ISIS.
xos0063429 The output of the command show fan shows the fan status as empty after a hot re-seating of the fan module.
xos0063457 Configuration for adding network VLAN port in STP for subscriber is not saved.
xos0063465 Cannot add/delete ports to load-shared MLAG ports without disabling MLAG.
xos0063478 Traffic drop occurs while adding new member port to the existing LAG group and PSTAG is configured on the port.
xos0063484 Enhancement added in STP flush generation mechanism to reduce hardware programming load.
xos0063493 Traffic stops after disabling, and then enabling LAG ports in VPLS service VLAN with static FDB.
xos0063585 AAA process ends unexpectedly when NetLogin primary RADIUS server is down and "Active directory domain services" alone is down in secondary NetLogin RADIUS server.
xos0063673 If one MAC address learned on the same port in a dynamic VLAN ages out, the whole dynamic VLAN is deleted after 20 seconds even though other MAC addresses are still in the FDB table.
xos0063710 Kernel oops occurs on switch with Private VLAN and MLAG configuration after executing <i>restart ports all</i>.
xos0063736 In Syslog, username information appears as "*****" during login/logout cases.
xos0063815 Traffic is dropped on one VPLS instance when another VPLS instance running on same switch is deleted.
xos0063853 Potential memory corruption when MAC locking is configured.
xos0063870 Kernel oops occurs due to memory overrun in user kernel interface.
xos0063956 ACL slice is not freed up after changing IGMP snooping filter from per-vlan to per-port mode.
xos0054714 When ACLs are applied in both ingress and egress directions, you cannot see egress direction using SNMP. When a policy has more than one counter, using SNMP, you can only check the updates from the first counter, and subsequent counters do not appear.
xos0059481 Static FDB is programmed incorrectly in hardware after a stack failover.
xos0062902 Kernel oops occurs while disabling service VMAN with CEP configuration.
xos0063521 A few IBGP routes are not updated in routing table when <i>disable bgp</i> and <i>enable bgp</i> commands are executed in quick succession.
xos0063547 Process ACL ends unexpectedly after applying a policy file with source zone as a match condition.
xos0063644 exsshd process ends unexpectedly with signal 11 in rare scenarios.
xos0063814 UPM process ends unexpectedly with Signal 11 occasionally when UPM timers are configured.
xos0063365 Frequent MLAG bulk syncs observed due to checksum mismatch between MLAG peers when ISC port was added as an untagged port to a tagged VLAN and VRRP was running between the peers.
BlackDiamond 8800 Series Switches
xos0063552 Backup Master Switch Fabric Module (MSM) fails to reach 'In sync' state after bootup in fully loaded chassis with a large number of ACL rules applied.
xos0063614 Kernel crash occurs when receiving DHCP packets with invalid field values.
xos0063872 After multiple executions of run failover with redirect-flow configuration, IPv4 ping fails.
xos0063333 In BlackDiamond 8800 series switches, optics information is not detected and ports remain in "Ready" state after reboot.
BlackDiamond X8 Series Switches
xos0057363 Sample message with invalid slot ID received after enabling sFlow.
xos0063928 In BlackDiamond X8 series switches, Sysuptime in sFlow packets is invalid.
E4G 400 Cell Site Routers
xos0063370 PTP Delay Response correction field has high value (Junk value) when PTP Delay response packets were passing through combo ports.
SummitStack
xos0061777 Standby nodes do not come back up to operational state after they go into failed state.
xos0062853 Communication failure occurs between hosts connected to SummiStack after the stack is broken into two separate stacks, and then merged back to single stack.
xos0063490 CFM stays down after slot reboot on a stack.
xos0063788 The following error appears continuously in backup/standby nodes when node is put in the failed state due to a license/ExtremeXOS mismatch:
&amp;ltErro:DM.Error&amp;gt Slot-2: Node State[185] = FAIL (License Mismatch)
Summit X450-G2 Series Switches
xos0060129 On Summit X450-G2 series switches, 10/100/1000BASE-T SFP+ optics do not link to similar optics when in the SFP/SFP+ ports. They do link or partially link when connected to a regular triple speed copper port.
Summit X460 Series Switches
xos0063595 On Summit X460 series switches, the command to configure stacking ports does not show the native option.
Summit X460-G2 Series Switches
xos0062913 On Summit X460-G2 series switches, copper combo port does not advertise its flow control capabilities to peers.
xos0063495 Policy authentication fails when radius request queue has stale entries.
xos0063927 Error "Deferred L2 notification code out of sync unit 0" repeatedly appears in log.
Summit X670 Series Switches
xos0057671 Link status goes to Ready state on port with 10/100/1000BASE-T optics after multiple reboots.
Summit X670-G2 Series Switches
xos0063665 When Tenant VM connected to MLAG (LACP) ports is turned off, tenant VM FDB is not aged out even after the age out timer expires. The FDB entry persists.
xos0063807 On Summit X670-G2 series switches, egress ACL rule actions do not take effect on ports 64-72