Resolved Issues in ExtremeXOS 16.1.3-Patch1-11

The following issues were resolved in ExtremeXOS 16.1.3-Patch1-11. ExtremeXOS 16.1.3-Patch1-11 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3 and ExtremeXOS 16.1.3. For information about those fixes, see the release notes for the specific release.

CR Number Description
General
xos0055511

While configuring STP (802.1d) with port-encapsulation mode as EMISTP where the L2PT-enabled VMAN and access VLAN have the same tag, the designated bridge is not accepting the L2PT tunneled BPDUs from the root bridge, and thus causes a loop (designated bridge also becomes a root bridge).

This problem does not occur:
  • When the access VLAN's tag and the L2PT-enabled VMAN‘s tag are different.
  • Without any L2PT configured, with the same tag used for the access VLAN and provider-edge VMAN.
  • When using Per-VLAN Spanning Tree Plus (PVST+), regardless of same or different tags.
xos0064023 L3 table full log appears because of false resource full triggered by link flaps.
xos0064114 SNMP process ends unexpectedly with signal 6 after running the switch for a long time.
xos0064232 On Summit X670-G2 and X770 series switches, after changing a VPWS service VLAN tag, traffic continues to be forwarded with the prior tag.
xos0064423 In BlackDiamond 8800 and X8 series switches, flooding to a VPLS peer does not work after adding a new port to an existing LAG group.
xos0064523 Dynamic ACL rule is not removed properly when turning off packet capture.
xos0064525 Policy does not allow regular expression to be specified for BGP communities.
xos0064568 After slot reboot, traffic drop occurs on VPLS service VLAN LAG port.
xos0064575 "Operation draining timed out" error message appears while saving the configuration in stacking switch.
xos0064671 OSPFv3 incorrectly chooses higher path cost for a route based on the lower LS age.
xos0064735 VMAN CEP configuration gets removed from hardware while removing member port from LAG.
xos0064831 With a switch connected to two RADIUS servers (one for Netlogin and one for management access), the Netlogin RADIUS server is incorrectly chosen for switch web access.
xos0064884 "remove-private-AS-numbers" setting in BGP is not preserved after switch reboot.
xos0064909 Traffic loss occurs while changing and reverting the base VID of VLANs with PSTag ports.
xos0064910 Following error messages appear while changing and reverting back the base VLAN tag of VLANs with PSTag ports:
<Erro:Kern.MPLS.Error> MPLS bcm_esw_mpls_port_match_vlan_del failed for unit = 0, port = 0xffffffff vp = 0xe, match_vlan = 0 match_inner_vlan = 0, rv = -7 (Entry not found)
xos0064956 EDP neighbors are not displayed when remote mirroring is disabled or after unconfiguring a monitor port of remote mirroring.
xos0064960 Multicast traffic is forwarded through MVR receiver port in a VLAN even if there is no active receiver.
xos0065073 Kernel oops observed when IPv6 duplicate address detected in the switch.
xos0065189 BGP secondary best path is not active when primary best path goes down.
xos0065261 Traffic loss occurs in one VLAN when another VLAN with a loop causes significant congestion.
xos0065291 One-to-many mirroring is not working.
xos0065292 Traffic is not forwarded from member VLAN to untagged ports in translation VLAN.
Summit X460-G2 Series Switches
xos0064684 On Summit X460-G2 series switches, ESVT test does not start if the loopback port used is a 10G port.
Summit X670-48X Series Switches
xos0064855 On Summit X670-48X switches, some ports do not become active when using 5 M SFP+ passive copper cable connected to Summit X45-0G2 series switches.