Resolved Issues in ExtremeXOS 21.1.3-Patch1-7

The following issues were resolved in ExtremeXOS 21.1.3-Patch1-7. ExtremeXOS 21.1.3-Patch1-7 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3, ExtremeXOS 21.1.1, ExtremeXOS 21.1.2, and ExtremeXOS 21.1.3. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 21.1.3-Patch1-7

CR Number Description
General
xos0062758 With policy enabled, client authenticated using NetLogin is not getting aged out when reauthentication is configured.
xos0065527 Edge safeguard configuration gets lost when ports are removed and added back to default VLAN.
xos0066477 Creating a VLAN starting with "vr" causes syntax recognition problems with the show iparp vr command.
xos0066557 Kernel crash occurs after removing a subVLAN from one VR and adding the same subVLAN in another VR.
xos0066932 Actual/configured sFlow sample rates are different after reconfiguring.
xos0066984 RADIUS-accounting request packet shows incorrect account-terminate reason for user logout from SSH/Telnet session.
xos0066996 ESRP does not update the neighbor state properly while becoming master from neutral state.
xos0067002 UPM status is "fail" if UPM profile has <i>save configuration as-script</i> as the last command.
xos0067079 ACL installation for the policy authenticated client is failing when diffserv replacement and meter configuration is present in the switch.
xos0067108 Packets received on STP blocked ports gets forwarded to other STP port when netlogin & onePolicy is enabled with authentication mode optional.
xos0067323 FDBs are learned on incorrect VPLS peer on PE switches after include/exclude dot1q tag in P switch.
xos0067325 After recovering from multiple link failures, ERPS incorrectly keeps both the ring links in blocked state.
xos0067335 Memory leak occurs in VMT process when it is enabled on the port.
xos0067463 Traffic does not distribute across LSPs and LAG after enabling L2VPN sharing feature.
xos0067506 A few VRRP instances remain in dual master state if VRRP state changes for several VLANs in the same VRID within a short time period.
xos0067820 ExtremeXOS refuses connections with usernames starting with letters h, i ,j, k, p, q, r, and s using SOAP/XML.
xos0067887 Switch reboots unexpectedly when there are continuous SSH attempts and those attempts are rejected with access-profile.
xos0067912 The command show port protocol filter displays the "Error: Configuration reply is too big" in output.
xos0068209 PIM process ends unexpectedly with signal 11.
xos0066941 Add a support for USB Zero Touch Provisioning.
xos0067583 Add support to configure ping success for VRRP track-ping.
xos0067973 After run failover, IDM kerberos system ACLAs are missing for some users in new master.
xos0059947 Spurious log messages occur in the hardware while deleting tenant VLAN in the switch.
xos0065930 ACLCBFUNC log occurs after associating a policy that has CLEAR-flow and network-zone configuration.
xos0066883 Process HAL ends unexpectedly with signal 11 on restarting all ports with basic VXLAN configuration.
xos0066921 ARP fails to resolve for some hosts.
xos0067084 FDB is not learned over pseudowire after disabling, and then enabling, learning on network VLAN ports.
xos0068099 After rebooting the switch, BGP neighbor configuration is lost when a peer group is configured.
xos0067087 CFM LMR/DMR packets are sent with dot1p value 0.
xos0065571 Ping fails over L3VPN tunnel when the corresponding ARPs are in Layer 3 hardware hash table as "Extended View". Affects Summit X450-G2, X670-G2, and X770 platforms.
xos0060343 On Summit X670v stack, configuration file replication on standby nodes times out after second or third failover.
xos0067106 In dot1x authorization, service unavailable vlan port is re-authenticated in every authorization causing blocked port.
xos0063669

Erro:RtMgr.Client.ReplyTimeOut messages appear after run failover/reboot:

<Warn:EPM.hello_rate> Slot-2: Received hellos from process rtmgr 2 more often then expected 3
<Erro:RtMgr.Client.ReplyTimeOut> Slot-2: Client with ID=0x00000012 Timed out waiting for (ADDUPDRTE). 
<Erro:RtMgr.Client.ReplyTimeOut> Slot-2: Client with ID=0x00000012 Timed out waiting for (RTEGET).
xos0067446 "ACL filter update failed" error occurs when modifying the code point value.
xos0066963 Jumbo frame is disabled on master port after rebooting when ports are partitioned.
xos0062668 MIB compilation issues occur with VLAN MIB when using mgsoft.
xos0066697 Delay occurs in password prompt appearing when trying to establish SSH connection.
xos0064870 Slots fail sometimes when applying PVLAN and STP configuration.
Summit X440-G2 Series Switches
xos0066945 On Summit X440-G2 series switches, 10G ports are not coming up with 5-meter passive copper cable when connected to ExtremeSwitching X620-16X.
Summit X670-G2 Series Switches
xos0066844 Port with copper SFP inserted appears as active even if it is administratively disabled.
SummitStack
xos0058499 In SummitStack, the snmpEngine values are maintained in each node separately instead of a single value, which is causing different values on each failover.