Resolved Issues

This section details the issues that are resolved in this release.

Resolved Issues in VOSS 8.4

Issue number

Description

VOSS-9206

Interface statistics InDiscard counter in show interfaces gigabitEthernet error output does not increment consistently when IPv6 packets are dropped when uRPF checks fail.

This issue applies only to VSP 4450 Series.

VOSS-13948

After you enable MSTP-Fabric Connect Multi Homing (spbm 1 stp-multi-homing enable), MSTP resiliency times are 30 to 40 seconds because the internal SPB-STP port is not fast-aging remote CMAC entries after a topology change occurs.

VOSS-15387

Silent resets resolved for the VSP 4450 Series.

VOSS-18486

MACsec cannot be enabled on 100 Mb links of multirate ports on the 5520-12MW-36W switch. Customers who want to secure their 100 Mb links must use only ports 1/1 to 1/36. Ports 1/37 to 1/48 cannot be used for this purpose.

VOSS-18650

BGP connection issue between directly connected peers.

VOSS-18859

For VSP 7400 Series, IPFIX flows timestamp and observation time is not in sync with the system time.

VOSS-19374

Switch does not display the correct date in the dir -l output.

VOSS-19867

If Zero Touch Provisioning Plus (ZTP+) begins before the switch has acquired an IP address, DNS, and domain name, it can time out before the onboarding process is complete. The onboarding process completes after the next switch reboot but you must remove the previous entry for the switch in the Extreme Management Center Discovered Devices tab.

VOSS-20100

On DvR Controllers, the output of the show dvr members command can display an incorrect SPB L1 cost. This issue has no impact because DvR does not use this value on DvR Controllers; DvR only uses this value on Leaf nodes.

VOSS-20117

You cannot change the password of an existing user from Extreme Management Center during ZTP+ onboarding.

VOSS-20214

Mitel phones require the LLDP 802.3 MAC/PHY TLV together with LLDP-MED to function properly. VOSS does not currently support the 802.3 MAC/PHY TLV.

VOSS-20241

On the VSP 4900 Series, when applying ACL with mask as 32-bit, it applies as 255.255.255.255 instead of 0.0.0.0.

VOSS-20309

Although you can configure Bidirectional Forwarding Detection (BFD) on Layer 2 core Fabric Extend logical-interfaces, BFD sessions cannot be established over Layer 2 core Fabric Extend interfaces.

VOSS-20610

After a personality change from EXOS to VOSS 8.3 on a factory-shipped 5520 Series switch, the save config command fails with the following message: CP-1: Directory Not Specified doesn't exist. Save config to file Not Specified is not possible..