Logo

AP122 Hardware User Guide

AP122 Hardware User Guide

Read about and view specifications and compliance information for the AP122 in this topic. Install the AP122 using this topic.

The AP122 is optimally suited for medium capacity environments. The AP122 features dual 2x2, 2-stream radios, providing dual 802.11n or 11n/ac performance with data rates up to 867 Mbps using existing 802.3af PoE infrastructure.

For more information about Extreme Networks APs in general, see Introduction to Extreme APs.

For information about connecting your AP to the network, best-practices, and troubleshooting, see Onboarding New Devices Troubleshooting Tips

For regulatory and compliance information, see "Regulatory Compliance Statements".

If your access point is configured for the World Regulatory Domain, it is important to set the country code to the country in which the AP will be deployed to meet regulatory requirements and for optimal wireless operation. To do this, follow these steps:

Note

Note

The country code selection is for World models only and is not available to FCC, CAN, and other country-specific models. Per FCC regulations, all Wi-Fi products marketed in the United States must be set to U.S. channels only.

For Devices Running HiveManager

  1. Power on the AP and allow it to find and connect to ExtremeCloud IQ. Once the AP is connected it appears in the table of devices on the Manage > Devices page.
  2. Select the check box next to the AP, and then choose Assign Country Code from the Actions drop-down list. In the dialog box, select the appropriate country from the drop-down list, and then click Save.
  3. Upload your changes to the device.

For Devices Running HiveManager Classic

  1. Power on the AP and allow it to find and connect to HM Classic. Once the AP is connected, it appears in the table of unconfigured devices on the Manage > Devices page and is categorized as New under the Management Status table header.
  1. Select the check box for the AP, and then choose Update > Advanced > Update Country.
  2. On the Update Country Code page, choose the appropriate country code from the drop-down list, and then click Upload.

Safety Guidelines

Safety Guidelines

The information in this section applies to AP122 devices.

The following safety icons are used in these guidelines to identify the type of precaution:

This icon indicates a general caution. Failure to comply with a caution notification can result in damage to equipment.
This icon indicates an electrical caution. Failure to comply with an electrical notification can result in serious injury or death, and extensive damage to equipment.
This icon indicates a laser caution. Failure to comply with a laser caution can result in serious injury.
The following table lists the safety precautions you should follow when installing your AP122 devices.
Extreme Networks devices must be installed by a professional installer who is certified to install these types of devices and to ensure that they are properly grounded and meet applicable local and national electrical codes.
These devices are intended for indoor use only.
Do not install the device in an environment where the operating ambient temperature might exceed the recommended ranges.
For products available in the USA/Canada market, for the 2.4 GHz band, only channels 1-11 can be operated. Selection of other channels is not possible.
Changes or modifications made to this device that are not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Use only attachments and accessories specified by Extreme Networks.
These devices are not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or with lack of experience of knowledge unless they are given supervision or instruction concerning use of the devices by a person who is responsible for their safety. Children should be supervised to ensure that they do not play with the devices.
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs when electronic components are improperly handled and can result in complete or intermittent failures. Be sure to follow ESD-prevention procedures when handling electronic components and equipment.
During operation, the surfaces of the AP122 can become hot. Use caution when handling.
To meet federal radiation exposure requirements, these devices should be installed at a minimum distance of 7.8" (20 cm) from people or animals.

Install the AP

You can mount the AP122 on a flat surface or wall, or on the rails of a standard dropped ceiling grid using the hardware on the back of the chassis.

The following sections describe how to install your AP122 devices and connect them to the network.

Shipping Carton Contents

The AP122 access point shipping carton contains the following items:

Dropped Ceiling Mount

The following steps explain how to mount the AP122 on the rail of a dropped ceiling.

Make sure that you have all the materials and tools necessary, and familiarize yourself with the safety and site hazard warnings before you install the device. You may need to drill a small hole in the adjacent ceiling tile to accommodate the cable. Before you begin, lift the ceiling tiles adjacent to the location on the rail where you will install the device for better access. Once the device is installed, you can slide it along the rail to better adjust its position.

Use the following steps to install your device to a dropped-ceiling rail.

  1. For a dropped ceiling mount, use the mount tabs and clips on the bottom of the device.
  2. Hold the device upside down and slip the mount tabs over the sides of the ceiling rail.
  3. Press the device gently against the ceiling rail and rotate it until the mount clips click into place.

Wall or Non-dropped Ceiling Mount

Use the built-in wall mount slots on the back of the chassis to attach the AP122 to any vertical or horizontal surface (such as a wall or a drywall ceiling) that supports its weight (1.16 lb, or 0.56 kg), and to which you can install wall mount screws. To mount the AP122 on a wall or other flat surface, perform the following steps:

  1. Make two marks where you want to mount the device on the wall or surface exactly 2.5" (64 cm) apart.
  2. Drill two holes that are slightly smaller in diameter than the mounting screws.
  3. Install two wall mount screws (and plastic anchors if necessary). The screw heads must protrude far enough from the wall so that the chassis will slip over the screw heads, and leave enough room to access the console connector. If you are connecting the device to cables from inside the wall, drill an access hole for the cables.
  1. Insert the heads of the screws into the large end of the wall mount slots and slide the device down (or sideways for ceiling mounts) until the screws are seated in the narrow end of the keyholes.
  2. You can lock the device to the wall or ceiling using a security bracket that can be ordered as an accessory.
  3. To remove the device from the wall or ceiling, slide the chassis up until the screw heads slip out of the wall mount slots.
  4. The AP122 is PoE powered, so you must connect an Ethernet cable directly from the ETH0 port to a PoE-enabled switch or to a PoE injector.
Note

Note

You can also mount these devices to non-standard or recessed dropped ceiling tracks using brackets designed for 9/16" (1.34 cm) tracks. These brackets can be ordered from Extreme Networks (AH- ACC-BKT-80211AC-KIT). Not available in Brazil.

Remove the Device

To remove the device, press the mount clips until they disengage from the rail, then rotate the device and pull it away from the rail. A flat-blade screwdriver will make it easier to access and press the clips.

Lock the AP

You can secure the AP using a Kensington® lock in the lock slot on the side of the device, or you can use a security bracket and a crosshead screw or a security screw. Security brackets and screws can be ordered separately from Extreme Networks (not available in Brazil).

Extreme Networks recommends a variety of Kensington locks. For more information, contact your sales representative.

Connect the AP to the Network

Follow these steps to connect your AP122 to PoE (power over Ethernet) power and to the network.

  1. Connect a standard RJ45 Ethernet cable from ETH0 on the AP to a switch.
  2. If the switch provides PoE (power over Ethernet), cabling the AP to the switch will power-on the AP in a few seconds. If the switch does not provide PoE, use a PoE injector. For more information about Extreme Networks PoE injectors, contact your Extreme Networks representative.
  3. After you power on the AP, it automatically tries to get network settings and contact ExtremeCloud IQ. This process takes about five minutes. When you see the AP listed on the All Devices page in the Manage section of the ExtremeCloud IQ GUI, the initial setup is complete and you can begin managing the AP with ExtremeCloud IQ.

Hardware Components

You can see the hardware components of the AP122 in the illustration below and read about them in the sections that follow.

Component Descriptions

Status Indicator Light

The AP122 has a status light bar on the top corner and down one side of the chassis. This light conveys operational states for system power, firmware updates, Ethernet and wireless interface activity, and major alarms. The colors of the light indicate the following states of activity:

Dark: There is no power or the status indicator is disabled.

Amber (flashing): This is an alert that indicates that the device is performing a firmware upgrade. Do not power off the device during this process.

Amber (steady): This is an alert that indicates that the CAPWAP connection has not been successfully established, or the device is booting or shutting down.

White: The device is powered on, a successful CAPWAP connection has been made, and the firmware is operating normally. During normal operation, the LED produces a slow blink consisting of 4 seconds of illumination followed by one minute of darkness. To extend the life of the status LED, turn it off completely for normal use, and turn it on when needed for troubleshooting.

To extend the life of the status LED, turn it off completely for normal use, and turn it on when needed for troubleshooting.

To turn the LED on or off or change the brightness using the CLI, enter:

system led brightness [ bright | soft | dim | off ]

To turn the LED off, navigate to Configure > Network Policy > Additional Settings > Network Service > Management Options. Turn Management Options on and scroll down to the System Settings section.

Note

Note

When you change the brightness setting here, the new setting will apply to all devices under this network policy. To turn the LED off for a single device, establish a console connection with that device and use the CLI command.

Console Port

Through the Console port, you can make a serial connection between your management system and the AP. When you connect to the device using the RJ45 Console port, the management station from which you connect to the device must have a VT100 emulation program, such as Tera Term Pro© (a free terminal emulator) or Hilgraeve HyperTerminal® (provided with Windows® operating systems from XP forward). The serial connection settings are: 9600 bits per second, 8 data bits, no parity, 1 stop bit, no flow control.

The pin-to-signal mapping for the Console port is shown in Extreme Device Pin Assignments.

Power Connector

You can power the AP122 through the ETH0 port from PSE (power sourcing equipment) that is compatible with the 802.3af and 802.3at standards. Because there is no on/off switch, these devices automatically power on when you connect them to power.

Ethernet Port

The AP122 has one RJ45 10/100/1000Base-T/TX Ethernet port (ETH0) that automatically negotiates half- and full-duplex connections with the connecting device. The port is autosensing and adjusts to straight-through and crossover standard Cat3, Cat5, Cat5e, or Cat6 Ethernet cables automatically. The AP receives PoE power through an Ethernet connection to the ETH0 port from PSE (power sourcing equipment) that is compatible with the 802.3at and 802.3af standards.

Power sourcing equipment can be embedded in a switch or router, or it can come from purpose-built devices that inject power into the Ethernet line en route to the AP. Because the PoE port has autosensing capabilities, the wiring termination in the Ethernet cable can be either straight-through or crossover.

You can purchase your own PoE injector or purchase the following PoE injectors as optional accessories from Extreme Networks (not available in Brazil):

USB Port

The AP122has a USB port that you can use to connect USB-based beacons (iBeacon, for example) and IoT (Internet of Things) devices. To access the port, remove the screw that secures the protective cover. For extra protection, keep the cover in place when the port is not in use.

Reset Button

Use the Reset button to reset the device or restore the factory default settings. Insert a paper clip or similar tool into the Reset pinhole and press the button. To reboot the device, press the button for 5 seconds. To return the configuration to the factory default settings, press it for at least 10 seconds. After releasing the button, the indicator light goes dark, and then glows steady amber while the firmware loads and the system performs a self-test. After the software finishes loading and the AP has connected to ExtremeCloud IQ, the status indicator glows steady white.

To prevent the reset button from resetting the configuration, enter the following command:

no reset-button reset-config-enable

When this command is enabled, pressing the button for 5 seconds will still reboot the AP, but pressing it for more than 10 seconds will not reset its configuration.

Antennas

The AP122 has four internal single-band antennas: two 2.4 GHz antennas (802.11a/b/g/n)and two 5 GHz antennas (802.11a/b/g/b/ac). All antennas are omnidirectional and provide fairly equal coverage in all directions.

Lock Slot

When mounting the AP on a ceiling track or flat surface, you can secure it to the track using a Kensington® lock in the lock slot or using the security screw and bracket that ships with the device. See "Locking the AP".

Hardware Specifications

The following specifications describe the physical features and hardware components, the power adapter and PoE electrical requirements, and the temperature and humidity ranges in which the devices can operate.

Radio Specifications

802.11a

802.11b

802.11g

802.11n

802.11ac

Device Specifications

Antenna Gain

Power Specifications

Environmental Specifications

Regulatory Compliance Statements

The regulatory compliance statements in this section apply to Extreme NetworksAP122 devices.

Japan Indoor Use

Note

Note

For Japan, the AP122 is restricted for indoor use in the 5150-5350 MHz band only.

Compliance Statement - Europe

EU Declaration of Conformity

View this information online at www.aerohive.com/support/regulatory-compliance

Extreme Networks, Inc. declares that this device complies with the essential requirements of the Radio Eqiupment Directive 2014/53/EC.

This product supports the following radio frequencies and power levels in the EU version:

Bulgarian [български]: Този продукт поддържа следните радиочестоти и нива на мощност във версията на ЕС:

Croatian [hrvatski]: Ovaj proizvod podržava sljedeće radijske frekvencije i razinu snage u verziji EU:

Česky [Czech]: [Tento produkt podporuje následující rádiové frekvence a úrovně výkonu ve verzi EU:

Danish [Dansk]: Dette produkt understøtter følgende radiofrekvenser og strømniveauer i EU-versionen:

Dutch [Nederland]: Dit product ondersteunt de volgende radiofrequenties en vermogensniveaus in de EU-versie:

English: This product supports the following radio frequencies and power levels in the EU version:

Estonian [Eesti]: See toode toetab järgmisi raadiosagedusi ja võimsuse taseme ELis versioon:

Finnish [Suomi]: Tämä tuote tukee seuraavia radiotaajuuksia ja tehoja EU-versiossa:

French [Français]: Ce produit prend en charge les fréquences radio et les niveaux de puissance suivants dans la version EU:

German [Deutsch]: Dieses Produkt unterstützt die folgenden Funkfrequenzen und Leistungsstufen in der EU-Version:

Greek [Ελληνική] Αυτό το προϊόν υποστηρίζει τις ακόλουθες ραδιοσυχνότητες και επίπεδα ισχύος στην έκδοση της ΕΕ:

Hungarian [Magyar]: Ez a termék a következő rádiófrekvenciákat és teljesítményszinteket támogatja az EU verziójában :

Italian [Italiano]: Questo prodotto supporta le seguenti frequenze radio e livelli di potenza nella versione UE:

Latvian [Latviski]: Šis produkts atbalsta šādus radio frekvences un jaudas līmeni ES versiju:

Lithuanian [Lietuvių]: Šis produktas palaiko šiuos radijo dažnius ir galios lygį ES versija:

Maltese [Malti]: Dan il-prodott jappoġġja l-frekwenzi tar-radju li ġejjin u l-livelli ta 'enerġija fil-verżjoni UE:

Pollish [Polski]: Ten produkt obsługuje następujące częstotliwości radiowe i poziomy mocy w wersji unijnej:

Portuguese [Português]: Este produto suporta as seguintes frequências de rádio e níveis de potência na versão UE:

Romanian [Romania]: This product supports the following radio frequencies and power levels in the EU version

Slovak [Slovensky]:Tento produkt podporuje nasledujúce rádiové frekvencie a úrovne napájania vo verzii EÚ:

Slovenian [Slovenija]: Ta izdelek podpira te radijske frekvence in ravni moči v različici EU:

Spanish [Español]: Este producto admite las siguientes frecuencias de radio y niveles de potencia en la versión de la UE:

Swedish [Sverige]: Denna produkt stöder följande radiofrekvenser och effektnivåer i EU-versionen:

UK: This product supports the following radio frequencies and power levels in the EU version:

To meet radiation exposure requirements, these devices should be installed at a minimum distance of 11" (28 cm) from people or animals.

Restrictions: 5150-5250 MHz for indoor use only.

Bulgarian [български]: За да отговарят на изискванията за излагане на радиация, тези устройства трябва да бъдат инсталирани на минимално разстояние от 28 см от хората или животните.

Ограничения: 5150-5250 MHz само за вътрешна употреба.

Croatian [hrvatski]: Da bi zadovoljili zahtjeve izloženosti zračenju, ti uređaji trebaju biti instalirani na minimalnoj udaljenosti od 28 cm od ljudi ili životinja.

Ograničenja: 5150-5250 MHz samo za unutarnju uporabu.

Czech [Česky]: Aby byly splněny požadavky na ozáření, měly by být tato zařízení instalována v minimální vzdálenosti 28 cm od lidí nebo zvířat.

Omezení: 5150-5250 MHz pouze pro vnitřní použití.

Danish [Dansk]: For at opfylde kravene til strålingseksponering skal disse enheder installeres i mindst 11" (28 cm) afstand fra mennesker eller dyr.

Restriktioner: 5150-5250 MHz kun til indendørs brug.

Dutch [Nederland]: Om aan stralingsblootstelling te voldoen, dienen deze apparaten op een minimumafstand van 11" (28 cm) van mensen of dieren te worden geïnstalleerd.

Beperkingen: 5150-5250 MHz alleen voor gebruik binnenshuis.

English: To meet radiation exposure requirements, these devices should be installed at a minimum distance of 11" (28 cm) from people or animals.

Restrictions: 5150-5250 MHz for indoor use only.

Estonian [Eesti]: Et rahuldada kiirituse nõuetele, need seadmed tuleb paigaldada minimaalselt 11" (28 cm) inimestelt või loomadelt.

Piirangud: 5150-5250 MHz sisetingimustele.

Finnish [Suomi]: Säteilytysvaatimusten täyttämiseksi nämä laitteet on asennettava vähintään 11" (28 cm) etäisyydelle ihmisistä tai eläimistä.

Rajoitukset: 5150-5250 MHz vain sisäkäyttöön.

French [Français]: Pour répondre aux exigences d'exposition aux rayonnements, ces appareils devraient être installés à une distance minimale de 11" (28 cm) des personnes ou des animaux.

Restrictions: 5150-5250 MHz pour usage intérieur seulement.

German [Deutsch]: Um die Anforderungen an die Strahlenbelastung zu erfüllen, sollten diese Geräte in einem Abstand von 11" (28 cm) von Personen oder Tieren installiert werden.

Einschränkungen: 5150-5250 MHz nur für den Innenbereich.

Greek [Ελληνική]: Για την κάλυψη των απαιτήσεων έκθεσης σε ακτινοβολία, οι συσκευές αυτές πρέπει να τοποθετούνται σε απόσταση τουλάχιστον 28 cm από ανθρώπους ή ζώα.

Περιορισμοί: 5150-5250 MHz μόνο για εσωτερική χρήση.

Hungarian [Magyar]: A sugárterhelési követelmények teljesítése érdekében ezeket az eszközöket legalább 11" (28 cm) távolságra kell felszerelni az emberek vagy az állatoktól.

Korlátozások: 5150-5250 MHz csak beltéri használatra.

Italian [Italiano]: Per soddisfare i requisiti di esposizione alle radiazioni, questi dispositivi devono essere installati ad una distanza minima di 28 cm da persone o animali.

Restrizioni: 5150-5250 MHz solo per uso interno.

Latvian [Latviski]: Lai apmierinātu starojuma iedarbības prasībām, šīs ierīces ir uzstādītas pie minimālo attālumu 11" (28 cm) no cilvēkiem vai dzīvniekiem.

Ierobežojumi: 5150-5250 MHz izmantot tikai telpās.

Lithuanian [Lietuvių]: Siekiant patenkinti SPINDULIAVIMĄ reikalavimus, šie įtaisai turi būti įrengiami ne arčiau kaip 11" (28 cm) nuo žmonių ar gyvūnų.

Apribojimai: 5150-5250 MHz naudoti tik patalpose.

Maltese [Malti]: Biex jilħqu l-ħtiġiet ta 'espożizzjoni tar-radjazzjoni, dawn il-mezzi għandhom jiġu installati f'distanza minima ta' 11" (28 ċm) minn nies jew annimali.

Restrizzjonijiet: MHz 5150-5250 għall-użu fuq ġewwa biss.

Polish [Polski]: Aby spełnić wymagania dotyczące narażenia na promieniowanie, urządzenia te powinny być instalowane w odległości minimum 11" (28 cm) od ludzi lub zwierząt.

Ograniczenia: 5150-5250 MHz tylko do użytku wewnętrznego.

Portuguese [Português]: Para atender aos requisitos de exposição à radiação, esses dispositivos devem ser instalados a uma distância mínima de 28 cm (11") de pessoas ou animais.

Restrições: 5150-5250 MHz para uso interno apenas.

Romanian [Romania]: Pentru a îndeplini cerințele de expunere la radiații, aceste dispozitive ar trebui instalate la o distanță minimă de 28 cm de la oameni sau animale.

Restricții: 5150-5250 MHz numai pentru uz intern.

Slovak [Slovensky]: Ak chcete splniť požiadavky na vystavenie žiareniu, mali by byť tieto zariadenia inštalované v minimálnej vzdialenosti od ľudí alebo zvierat od minimálnej vzdialenosti 28 cm.

Obmedzenia: 5150-5250 MHz iba pre vnútorné použitie.

Slovenian [Slovenija]: Da bi zadovoljili zahteve izpostavljenosti sevanja, morajo biti te naprave nameščene na razdalji najmanj 11" (28 cm) iz ljudi ali živali.

Omejitve: 5150-5250 MHz samo za uporabo v zaprtih prostorih.

Spanish [Español]: Para cumplir con los requisitos de exposición a la radiación, estos dispositivos deben instalarse a una distancia mínima de 11" (28 cm) de personas o animales.

Restricciones: 5150-5250 MHz sólo para uso en interiores.

Swedish [Sverige]: För att uppfylla kraven på strålningsexponering bör dessa enheter installeras på minst 11" (28 cm) från människor eller djur.

Restriktioner: 5150-5250 MHz endast för inomhusbruk.

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

IMPORTANT NOTE:

Radiation Exposure Statement:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 12.6" (32 cm) between the radiator and people or animals.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Country Code selection feature to be disabled for products marketed to the US/CANADA.

Brazil Statement

Este equipamento não tem direito à proteção contra inteferência prejudicial e não pode causar interferência em sistemas devidamente autorizados.

Mexico Statement

La operación de este equipo está sujeta a las siguientes dos condiciones

(1) es posible que este equipo o dispositivo no cause interferencia perjudicial y

(2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.

The operation of this equipment is subject to the following two conditions:

(1) it is possible that this equipment or device does not cause disruptive interference and

(2) this equipment or device must accept any interference, including interference that may cause undesired operation).

Industry Canada Statement:

This device complies with Industry Canada license-exempt RSS standards. Operation is subject to the following two conditions:

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :

Caution:

(i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;

Avertissement:

(i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux;

Radiation Exposure Statement:

This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 32 cm between the radiator and people or animals.

Déclaration d'exposition aux radiations:

Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 32 cm de distance entre la source de rayonnement et des personnes ou des animaux.

Taiwan Compliance Information

Extreme AP122

第十二條→經型式認證合格之低功率射頻電機,非經許可,公司,商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。

第十四條→低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。

前項合法通信,指依電信法規定作業之無線電通信。 低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。

 

在 5.25-5.35 秭赫頻帶內操作之無線資訊傳輸設備,限於室內使用。

無線資訊傳設備的製造廠商應確保頻率穩定性,如依製造廠商使用手冊上所述正常操作,發射的信號應維持於操作頻帶中。

Taiwan MPE Warning

電磁波曝露量MPE標準值(MPE) 1mW/cm2,送測產品實值為0.734 mW/cm2

Copyright © 2020 Extreme Networks. All rights reserved. Published March 2020.