View VLAN Forwarding Database Information
About this task
Perform this procedure to view forwarding database entries for all VLANs on the device.
Procedure
- In the navigation pane, expand .
- Select VLANs.
- Select the Forwarding tab.
Forwarding Field Descriptions
Use the data in the following table to use the Forwarding tab.
Name |
Description |
---|---|
VlanId |
Specifies the VLAN ID in the range of 1 to 4059. By default, VLAN IDs 1 to 4059 are configurable and the system reserves VLAN IDs 4060 to 4094 for internal use. On switches that support the vrf-scaling and spbm-config-mode boot configuration flags, if you enable these flags, the system also reserves VLAN IDs 3500 to 3998. VLAN ID 1 is the default VLAN and you cannot create or delete VLAN ID 1. |
Address |
Specifies a unicast MAC address for which the VLAN has forwarding or filtering information. |
Status |
Specifies the status of the VLAN. |
Port |
Specifies either a value of zero (0) or the port number of the port on which a frame having the specified MAC address was seen. A value of cpp indicates a self-assigned MAC address. |
BMac |
Shows the backbone MAC address if the entry is learned from a Shortest Path Bridging MAC (SPBM) network. |
Cvid |
Specifies the customer VID. |