Configure the Counter Sampling Interval
Configure the counter sampling interval values at port level to determine how often the sFlow agent polls and exports counters for a configured interface.
Before you begin
You must globally enable sFlow.
Procedure
Example
Verify all slots use the default polling-interval configuration.
Switch:1(config-if)#sflow counter-interval 525
Switch:1(config-if)#show sflow interface 1/1-1/10
===============================================================================
sFlow Port Configuration Info
===============================================================================
Port Packet-Sample-Rate Max-Header-Size Counter-interval Collector-list
(in secs)
--------------------------------------------------------------------------------
1/1 0 128 525 1,2
1/2 0 128 525 1,2
1/3 0 128 525 1,2
1/4 0 128 525 1,2
1/5 0 128 525 1,2
1/6 0 128 525 1,2
1/7 0 128 525 1,2
1/8 0 128 525 1,2
1/9 0 128 525 1,2
1/10 0 128 525 1,2
--------------------------------------------------------------------------------
All 10 out of 10 Total Num of sflow port entries displayed
Variable Definitions
Use the data in the following table to use the sflow counter-interval and show sflow interface commands.
|
Variable |
Value |
|---|---|
|
<1–3600> |
Specifies the polling interval for a slot. Default value is 0 (disabled). |
|
{slot/port[/sub-port][-slot/port[/sub-port]][,...][slot/all][all]} |
Identifies the
slot and port in one of the following formats:
|