View DDI Voltage Information
About this task
This command displays information for DDI transceivers.
Procedure
Example
Switch:1#show pluggable-optical-modules voltage
================================================================================
Pluggable Optical Module Voltage(V)
================================================================================
PORT LOW_ALARM LOW_WARN ACTUAL HIGH_WARN HIGH_ALARM THRESHOLD
NUM THRESHOLD THRESHOLD VALUE THRESHOLD THRESHOLD STATUS
--------------------------------------------------------------------------------
1/2 0.1281 0.0 1.2596 0.5376 1.6396 Normal
1/3 0.0001 0.0 1.2596 0.3072 1.6396 Normal
1/9 0.0006 0.0 1.2596 2.6368 0.0 Normal
1/15 0.0006 0.0 1.2596 2.6368 0.0 Normal
2/1 0.0006 0.0 1.2596 2.6368 0.0 Normal
2/2 0.0006 0.0 1.2596 2.6368 0.0 Normal
2/3 0.0006 0.0 1.2596 2.6368 0.0 Normal
Variable Definitions
Use the data in the following table to use the show pluggable-optical-modules voltage command.
|
Variable |
Value |
|---|---|
|
{slot/port[/sub-port][-slot/port[/sub-port]][,...][slot/all][all]} |
Identifies the
slot and port in one of the following formats:
|