Inlet Air Temperature Reporting

Version 33.3.1 adds software support for measuring and reporting the inlet air temperature of a switch using an Extreme-supplied USB dongle temperature sensor. When the sensor is inserted, the temperature will be reported as follows:

# show temperature 
Field Replaceable Units                                  Temp (C)   Status   Min  Normal   Max
-------------------------------------------------------  ---------  -------  ---  -------  ---
Switch                : 5520-24W                           68.38    Normal     0   10-100  110
Switch                : Inlet Air                          21.50

For switch models that support two USB ports, the sensor works in either port, but only one sensor will work at a time if two are plugged in. If two are installed and one is removed, the second one must be re-seated for the kernel/operating system to detect and use it.

Supported Platforms

4120, 5420, 5520, 5720, and 7520-48XT models.

Modified CLI Commands

The following commands are modified to show USB temperature sensor information:

show temperature

New EMS Messages

The following new EMS messages are added to report when the sensor is installed and removed:

#show log chronological match temperature
<Info:HAL.Sys.USBTmpSnsrInstl> USB temperature sensor (FW-ESTSv1.0 HW-v1.3T) installed. Use 'show temperature' to display the inlet air temperature.
<Info:HAL.Sys.USBTmpSnsrRem> USB temperature sensor removed.