Precautions
Before installing an AP-8163 model Access Point, verify the following
grounding and lightning protection guidelines:
- The installation professional should be familiar with all grounding requirements and
regional codes and ensure the Access Point and mounting asset are properly grounded. The
grounding cable for an AP-8163 must be at a minimum a #10 gauge wire cross section. The cable
can be attached to the unit using one of the following methods:
- Loosen the grounding screw, insert the grounding cable into the hole below it, and tighten
the screw.
- Loosen the grounding screw, wind the grounding cable around it, and tighten the
screw.
- Attach a ring lug to the grounding cable and secure it to the unit using the grounding
screw.
- To properly attach the grounding cable to the Access Point, refer to AP-8163 Grounding Post
on page 15.
- For Ethernet and lightning protection, it is recommended that a commercially available
off-the-shelf Lightning Protection Unit (LPU) be used on all shielded CAT5E Ethernet
connections. The LPU should be rated for outdoor use.
- For the best possible protection, each Access Point requires an LPU be installed adjacent
to the Access Point. If there is a LAN connection to an indoor network, a second LPU is
required at the cable entry point to the building.
Caution
Lightning damage is not covered under the conditions of a standard
product warranty. When installed correctly, Lightning Protection Units (LPUs) provide the best
protection from the harmful effects of lightning. Observe all regional and national codes that
apply for lightning protection.
- Verify the deployment environment has a continuous temperature range compatible with the
operating temperature range of the device.