You can recover from an upgrade failure
		by rerunning the upgrade, by performing a fresh installation and then restoring the system
		from a backup, or by reverting a TPVM snapshot.  
	 Procedure
- 
				To rerun the upgrade, follow the
					steps for the type of upgrade you were attempting. 
				
			
- 
				To perform a fresh installation
					and restore the system backup, take the following steps.
				
					- 
						Uninstall EFA to remove any components that might have been installed
							before the upgrade failed. 
						
					
- 
						Follow the steps for the type of installation you need.
						
					
- 
						Restore the EFA
							backup.
						
							efa system restore --backup-tar <filename>.tar.gz 
 
 
- 
				(For SLX-OS 20.3.2a or later) To revert TPVM from a snapshot and then restore
					EFA in a multi-node deployment, take the following steps.
				
					- 
						On the TPVM, ensure that the status of both nodes is Up.
						
					
- 
						On the SLX device that hosts the standby TPVM, create a TPVM
							snapshot.
						
							tpvm snapshot create withefa true 
 This step created a snapshot with all the data that EFA needs for
							restoring the database. Because this process stops the TPVM, you run it
							on the standby TPVM first.  
- 
						On the SLX device that hosts the active TPVM, create a TPVM snapshot. 
						
							tpvm snapshot create withefa true 
 
- 
						Ensure that TPVM is running on both devices and that both nodes are
							Up.
						
					
- 
						Upgrade EFA as described in Upgrade EFA on TPVM in a Multi-Node Deployment.
						
							 Tip    If this upgrade attempt
								fails, select  No
								when prompted, to uninstall the upgrade. You can still continue with
								the next step.  
 
- 
						On each SLX device that hosts a TPVM, revert to the TPVM snapshot. 
						
							device# tpvm snapshot revert 
 The revert process can take about 10 minutes. 
- 
						Verify that both nodes are Up.
						
					
- 
						If both nodes are not up, take the following steps.
						
							
								- Run tpvm stop on both nodes.
- Run tpvm start on both nodes.
- Run efa status again.