X465.1 # enable vpex X465.1 # reboot Are you sure you want to reboot the switch? (y/N) Yes Slot-1 VPEX X465.1 #
Note
After reboot, command prompt changes to show that you are in VPEX mode.Slot-1 VPEX X465.1 # enable sharing 1:10 group 1:10-1:11 lacp Slot-1 VPEX X465.2 # enable sharing 1:20 group 1:20-1:21 lacp
Slot-1 VPEX X465.1 # configure vpex port 1:10 slot 110 WARNING: This command will remove VLAN membership from the port 1:10. Do you want to continue? (y/N)Yes Slot-1 VPEX X465.2 # configure vpex port 1:20 slot 120 WARNING: This command will remove VLAN membership from the port 1:20. Do you want to continue? (y/N)Yes Slot-1 VPEX X465.3 # show slot Slots Type Configured State Ports Flags -------------------------------------------------------------------------------- Slot-1 X465 X465 Operational 64 M Slot-110 V400-48p-10GE4 Operational 52 Slot-120 V400-48p-10GE4 Operational 52 Flags : M - Backplane link to Master is Active B - Backplane link to Backup is also Active D - Slot Disabled I - Insufficient Power (refer to "show power budget") Slot-1 VPEX X465.9 # show vpex Virtual Port Extender: Enabled Cascade Port Slot ============= 1:10 110 1:20 120
Note
Observe that the show slot command shows the CB as slot 1 with the two BPEs as slots 110 and 120.Note
Observe that the show vpex command shows that ports 1:10 and 1:20 are the cascade ports connecting to the BPEs.Slot-1 VPEX X465.1 # enable sharing 110:49 group 110:49, 110:50 lacp
Slot-1 VPEX X465.1 # configure vpex port 110:49 slot 130 WARNING: This command will remove VLAN membership from the port 110:49. Do you want to continue? (y/N)Yes Slot-1 VPEX X465.3 # show slot Slots Type Configured State Ports Flags -------------------------------------------------------------------------------- Slot-1 X465 X465 Operational 64 M Slot-110 V400-48p-10GE4 Operational 52 Slot-120 V400-48p-10GE4 Operational 52 Slot-130 V400-48p-10GE4 Operational 52 Flags : M - Backplane link to Master is Active B - Backplane link to Backup is also Active D - Slot Disabled I - Insufficient Power (refer to "show power budget") Slot-1 VPEX X465.9 # show vpex Virtual Port Extender: Enabled Cascade Port Slot ============= 1:10 110 1:20 120 110:49 130
Slot-1 VPEX X465.1 # configure vlan Default delete port all Slot-1 VPEX X465.2 # create vlan v100 tag 100 Slot-1 VPEX X465.3 # configure vlan v100 add port 130:1-2, 120:1-2, 1:7 tagged
Slot-1 VPEX X465.3 # show port 130:49-50, 120:49-50, 1:7 statistics no-refresh Port Link Tx Pkt Tx Byte Rx Pkt Rx Byte Rx Pkt Rx Pkt Tx Pkt Tx Pkt State Count Count Count Count Bcast Mcast Bcast Mcast ====== ===== ======= ========== ========= ========== ======= ====== ======= ====== 130:1 A 97045942 6209457963 0 0 0 0 0 35 130:2 R 0 0 0 0 0 0 0 0 120:1 A 36 4715 97001731 6206623104 0 0 0 35 120:2 A 95802538 6897726741 95784987 7279063658 0 512 0 697 1:7 A 97045942 4715 97001731 6206623104 0 0 0 0 ====== ===== ======== ========= ========= ========== ====== ====== ======= ====== > in Port indicates Port Display Name truncated past 8 characters > in Count indicates value exceeds column width. Use 'wide' option or '0' to clear. Link State: A-Active, R-Ready, NP-Port Not Present, L-Loopback Slot-1 VPEX X465.13 # show port 130:49-50, 120:49-50, 1:7 qosmonitor no-refresh Port Qos Monitor Port QP1 QP2 QP3 QP4 QP5 QP6 QP7 QP8 Pkt Pkt Pkt Pkt Pkt Pkt Pkt Pkt Xmts Xmts Xmts Xmts Xmts Xmts Xmts Xmts ======================================================================================== 130:49 119682459 0 0 0 0 0 0 45 130:50 0 0 0 0 0 0 0 0 120:49 0 0 0 0 0 0 0 45 120:50 119803233 0 0 0 0 0 0 923 1:7 119803233 0 0 0 0 0 0 923