To display the PoE status per port, run the show inline-power info {detail} ports {port_list}  command. This command provides the following information:
      
        
          - 
            State—Displays the port power state: 
                - Disabled
- Searching
- Delivering
- Faulted
- Disconnected
- Other
- Denied
 
- 
            PD‘s power class—Displays the class type of the connected PD: 
                - “-----”: disabled or
                  searching
- “class0”: class 0 device
- “class1”: class 1 device
- “class2”: class 2 device
- “class3”: class 3 device
- “class4”: class 4 device
- “class5”: class 5 device
- “class6”: class 6 device
- “class7”: class 7 device
- “class8”: class 8 device
 
- Volts—Displays the measured voltage. A
            value from 0 to 2 is valid for ports that are in a searching or discovered state.
- Curr—Displays the measured current, in
            milliamperes, drawn by the PD.
- Power—Displays the measured power, in
            watts, supplied to the PD.
- Fault—Displays the fault value:
              - None
- UV/OV fault
- UV/OV spike
- Over current
- Overload
- Undefined
- Underload
- HW fault
- Discovery resistance fail
- Operator limit violation
- Disconnect
- Discovery resistance, A2D
                failure
- Classify, A2D failure
- Sample, A2D failure
- Device fault, A2D failure
- Force on error
 
 
      The 
detail command option
        lists all inline power information for the selected ports. Detail output displays the
        following information:
          - Configured admin state
- Inline power state
- MIB detect status
- Label
- Operator limit
- PD class
- Max allowed power
- Measured power
- Line voltage
- Current
- Fault status
- Detailed status
- Priority
* (CIT_32.1.1.6) 5720-24MW-SwitchEngine.1 # show inline-power perpetual 
Perpetual PoE
-------------
Disabled 
To display PoE fast information by port, run the 
show inline-power fast
        ports {port_list} command. This command displays the
        following information:
          - Port status (enabled/disabled)
- Operator limits
- Priority
- Detection method
* (CIT_32.1.0.383) 5720-24MW-SwitchEngine.2 # sh inline-power fast
State   Enable     Disconnect        Last Fast Boot Status    
-----   --------   ---------------   -------------------------
HW      Disabled   Deny-port         Succeeded
Cfg     Disabled   Deny-port      
State: (HW) Hardware state per-slot, (Cfg) Configured state per-slot.
Fast Boot Status:
  Succeeded - Fast PoE boot succeeded and configuration matches.
  Disabled  - Fast PoE was disabled in hardware at boot time.
  Mismatch  - Fast PoE booted but the configuration in hardware
              did not match the configuration file.
  Failed    - Fast PoE boot failed and PoE was reset.
* (CIT_32.1.0.383) 5720-24MW-SwitchEngine.3