Chassis Management Microservice

Log messages for the Chassis Management microservice

LogID Level Message Cause Remedy Impact
5001 Fatal Unable to connect to Operational Database Database is down Check Database status Service not operational
5002 Info Service started Service is starting up NA Chassis services becoming available
5003 Error I2C timeout, please power-cycle chassis, waited for: %v Service is starting up Restart the chassis Chassis unavailable until restarted
5004 Fatal Unable to connect to gRPC server, Error: %v The gRPC server could not be found and a connection could not be established The service will restart automatically The chassis service will not be available until the service is restarted
5005 Error gRPC failed with error: %v A gRPC message failed, the service may be down The service will restart automatically The chassis service will not be available until the service is restarted
5006 Fatal Failed to initialize microservice One of components needed to start the chassis service is not available The service will automatically restart The chassis service is not available until it is restarted
5007 Error Error getting system uptime %d Unknown Try again later, if the problem persists, contact support System uptime cannot be determined
5008 Error Error processing event [%s], error [%d] An unknown event was received Report the issue to Extreme Networks support Chassis Manager may not be fully functional
5009 Error Received empty request A request with no contents was received Report the issue to Extreme Networks support None
5010 Error Error unmarshalling received request %v Incompatible message was received Report the issue to Extreme Networks support Some Chassis manager functionality may not be available
5011 Error Unknown message type %v Chassis manager is not compatible with this message type Report the issue to Extreme Networks support Some Chassis manager functionality may not be available
5012 Error Failed to Unmarshal message as JSON, error = %v Chassis manager is not compatible with this message type Report the issue to Extreme Networks support Some Chassis manager functionality may not be available
5013 Warning ActivateResponse returned Failure. Time: %v Timeout occured during communication Retry the command Chassis Activate command failed
5014 Error Failed converting value %v to scalar, continuing with next update Incorrect value received in message Retry the command or configuration, contact support if persistent Command or config failed to apply and was ignored
5015 Info Shutdown processing: %s Chassis Service is going down The chassis is rebooting or being shutdown, or the service is being upgraded Chassis services will not be available until the service is restarted
5016 Info System initialization in complete. All services are UP System Initialization is complete NA System is up and running
5017 Error Firmware update to %s failed. Rolling back to previous firmware The new firmware did not come up completely Contact Customer Support Firmware update failed
5018 Error Sofware Rollback failed. msg: %s, err: %v Firmware Rollback Failed Contact Customer Support Rollback due to failed firmware update failed
5019 Error System initialization failed. Firmware %s, last reboot reason %v TBD Contact Customer Support System Initialization Failed
5020 Error Services %s are not up after %v System Initialization failed Contact Customer Support System Initialization failed
5021 Info Firmware change successful. Current Firmware version is %s Firmware change successful NA Firmware changed
5022 Error Sensor %s Current Value %d Crossed Warning Threshold %d Thermal Monitoring NA Fan Speed might Increase
5023 Error Sensor %s Current Value %d Crossed Warning Threshold %d Thermal Monitoring NA Fan Speed might Increase
5024 Error File %s Read Error %v OS File Operation Read Error NA Value is NULL
5100 Fatal Unable to Detect the Programming Device, Error: %v Device in Unhealthy state The system needs to be powered down The slots and chassis service will not be available until the device is detected
5201 Info Slot %v Inserted Bootup or Insertion of the Linecard NA Slot becomes available
5202 Info Slot %v Extracted Extraction of the Linecard NA Slot becomes unavailable
5203 Info Slot %v Powered Down Linecard has been powered down Check ConfigDB For SlotOff Slot Ports/Interface services are unavailable
5204 Info Slot %v Powered UP Linecard has been powered up after removal or using Config NA Slot Ports/Interface services are available
5205 Error Slot %v Failed Linecard Entered an faulty State TroubleShoot the LC using Poweroff/On , else replace if needed Slot Ports/Interface services are rendered DOWN