Extreme Fabric Automation 2.4.1 provides the following enhancements.
Feature | Description |
---|---|
Endpoint group configuration |
EFA does not distinguish between SRIOV (single-root input/output virtualization) and non-SRIOV connections. Therefore, it treats both connections the same way. A new parameter,
--single-homed-bfd-session-type , is available for
the following commands:
With the new parameter, you can determine the session type for a BFD session formed over a CEP port. The default type is auto, which means that the BFD session type is automatically determined based on whether the service type for the endpoint group is set to extension (software) or Layer 3 hand-off (hardware). |
EFA 2.4.1 support |
The following tables in Supported Platforms and Deployment Models are updated to include 2.4.1 or 2.4.x:
|