The following are limitations in ExtremeXOS system architecture that have yet to be resolved.
CR Number | Description |
---|---|
BlackDiamond 8000 Series Switches | |
xos0062138 | Enabling, and then disabling VRRP fabric routing generates
a HAL port error log messages similar to the
following:7/18/2015 11:07:17.75 <Erro:HAL.Port.Error> MSM-A: Failed to configure static mac move behavior on port 1:2. 07/18/2015 11:07:17.76 <Erro:HAL.Port.Error> MSM-A: Failed to configure static mac move behavior on port 1:3. 07/18/2015 11:07:17.76 <Erro:HAL.Port.Error> MSM-A: Failed to configure static mac move behavior on port 1:4. 07/18/2015 11:07:17.76 <Erro:HAL.Port.Error> MSM-A: Failed to configure static mac move behavior on port 1:5. |
BlackDiamond Series Switches | |
xos0063161 | For BlackDiamond 8800 and X8 series switches, when distributed ARP is turned on, a Layer-3 interface can have at most one load-share group. With more than one load-share group on a Layer-3 interface, packets can be dropped. |