Resolved Issues in ExtremeXOS 16.2

The following issues were resolved in ExtremeXOS 16.2. ExtremeXOS 16.2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, and ExtremeXOS 16.1.3. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 16.2
CR Number Description
xos0064215
The following log message appears when a subnet is reachable both using MPLS and non-MPLS:
<Warn:Kern.IPv4FIB.Warning> Slot-4: dest 0x0A420000 / 24  nexthop 0xAC11121E: Unable to add route to unit 1, rc Entry not found.  Shadow problem. 
Summit X430 Series Switches
xos0059486 On Summit X430 series switches, optics are not detected after repeated removal and reinsertion of optics when CPU is busy.
xos0064084 In Summit X430 series switches, the command show power details displays fan status as "empty".
Summit Series Switches
xos0059007 QSFP+ to SFP+ adapter support is added to work with all optical SFP+ transceivers with the exception of LRM and passive copper direct attach cables.
xos0059484 Gigabit Ethernet compliance value is shown as "UNKNOWN" for BXU/D optics. Also, DDMI values do not appear. Media Type appears as "NONE" in show ports configuration command.
xos0059508 Link does not come up when 1G BX U/D optics are inserted into 10G SFP+ ports.

Workaround: Configure the port for speed 1,000 with auto-negotiation “on” using the command configure port <> auto on speed 1000 duplex full. For Summit X670V switches, remove and then re-insert the optics. For all Summit switches, except the X670V, the corrected behavior persists even after rebooting. For Summit X670V switches after rebooting, the transceiver must be removed, and then re-inserted.

xos0062570 In SummitStacks, executing the command enable sflow ports all enables sFlow inappropriately on stacking ports.
xos0062821 ACL rules installed are not mapped to single virtual group even though ACL action-resolution mode is highest-priority.
Summit X440 Series Switches
xos0060466 RX CRC errors with traffic loss occur when “CBL, SFPP, PASSIVE 10GB-C10-SFPP, 10M" from Tyco is inserted into Summit X440-48t-10G switches SFP+.
xos0062362 On Summit X440-24t series switches, process rtmgr pid 1572 ends unexpectedly with signal 11 error after disabling BGP with compressed routes.
xos0062621 On Summit 440-8p switches, the show fan command output displays that the fan is unsupported.
xos0063627 ARP is not re-added to hardware after it is removed initially due to the table being full.
xos0064050 While running diagnostics on a Summit X440 10G model switch with revision 10 and diagnostics test version 6.0 or above, "Test loopback phy fiber" and "Test snake interface" fail.
Summit X440-G2 Series Switches
xos0063317 When policy is enabled one less than the max number of netlogin users can be handled per slot.
xos0062775 With 32 Up MEPs configured, saving and rebooting produces the following errors:
10/03/2015 18:14:06.81 <Noti:EPM.system_stable> System is stable. Change to warm reset mode
 10/03/2015 18:14:10.06 <Info:HAL.IPv4ACL.Info> Synching ACLs to Switch
 10/03/2015 18:14:10.35 <Info:HAL.IPv4ACL.Info> Done synching ACLs to Switch
 10/03/2015 18:15:11.73 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:33, 12, 33) - pibAclWrapInstall(1, 2, 1020, 5242950) returned "Table full".
 10/03/2015 18:15:11.77 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:33, 13, 33) - pibAclWrapInstall(1, 2, 1021, 5242950) returned "Table full".
 10/03/2015 18:15:13.26 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:5, 12, 33) - pibAclWrapInstall(1, 1, 1028, 5242950) returned "Table full".
 10/03/2015 18:15:13.30 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:5, 13, 33) - pibAclWrapInstall(1, 1, 1029, 5242950) returned "Table full".
 10/03/2015 18:15:15.47 <Info:HAL.Card.Info> Switch is operational
Summit X450-G2 Series Switches
xos0060129 On Summit X450-G2 series switches, 10/100/1000BASE-T SFP+ optics do not link to similar optics when in the SFP/SFP+ ports. They do link or partially link when connected to a regular triple speed copper port.
Summit X460 Series Switches
xos0063206 Cannot add L2 entries in hardware due to a full L2 table caused by hash collisions.
xos0063595 On Summit X460 series switches, the command to configure stacking ports does not show the native option.
xos0063948 Clearflow delta values are randomly not calculated properly.
Summit X460-G2 Series Switches
xos0060018 With a 0.5M, 40G QSFP MOLEX passive copper cable inserted, disabling the port where the optic is inserted, rebooting, and then enabling the port, the port stays in the ready state and doesn't come up as enabled.

Workaround: Remove and re-insert the optics. The port then comes up as enabled.

xos0061486 Combo ports have unsupported autonegotiation and half-duplex settings.
xos0062855 On the Summit X460-G2 series switches, VPLS packets are forwarded with two tags when the service VLAN ports are also members of an untagged VMAN.
xos0062913 On Summit X460-G2 series switches, copper combo port does not advertise its flow control capabilities to peers.
xos0063495 Policy authentication fails when RADIUS request queue has stale entries.
xos0063811 Summit X460-G2 series switches with ExtremeXOS 15.6 through 21.1, have the following limitations for SyncE input reference frequency:
  • Network clock does not lock with input SyncE source port 52 (both at 10G and 1G speed) on all 48-port models (X460-G2-48t, 48x and 48p).

    Workaround: For SyncE input at 10G, avoid port 52.

  • When the 10G ports operate at 1G speed, the network clock does not lock. Models with Ethernet BASE-T or Power over Ethernet (PoE) ports may lock on initial configuration, but do not lock after a save and reboot.

    Workaround: For SyncE input at 1G, use a 1G port, not a 10G port.

Summit X480 Series Switches
xos0054290 When a semicolon is missing from ACL matching criteria, the ACL process ends unexpectedly.
xos0060614 When exporting OSPF routes into BGP, and long policy name causes process dcbgp pid 1575 to end unexpectedly with signal 11.
xos0061251 For Summit X480, X460, X440, X430 series switches, and E4G-200 and E4G-400 cell site routers, Dot1p examination functionality does not work correctly for untagged ports when diffserv examination is enabled on those ports.
Summit X670 Series Switches
xos0060656 Link does not come up when 1G BX U/D optics are inserted into 10G SFP+ ports.

Workaround: Configure the port for speed 1,000 with auto-negotiation “on” using the command configure port <> auto on speed 1000 duplex full. For Summit X670V switches, remove and then re-insert the optics. For all Summit switches, except the X670V, the corrected behavior persists even after rebooting. For Summit X670V switches after rebooting, the transceiver must be removed, and then re-inserted.

xos0061167 Links become active without a connection with tri-speed Base-T SFP installed.
xos0061559 Enabling OpenFlow on VLANs causes double-wide ACL slice to be used even though it can fit in single-wide slice.
xos0063052 Traffic loss occurs on computer connected to Summit X670v-48t switches when the connected switch port is oversubscribed in 100 MB mode.
xos0063137 Known unicast traffic is not shared between the stacking high-gig trunk ports.
Summit X670-G2 Series Switches
xos0061791 On SummitStacks containing master and standby nodes of different switches, the standby node may go to failed state after a node reboot.
xos0062166 On Summit X670-G2 series switches configured with L3VPN, executing the clear iparp command causes the switch to reboot with Kernel Oops.
xos0063204 Traffic stops on LAG ports when frequently modifying the sharing group.
xos0063807 On Summit X670-G2 series switches, egress ACL rule actions do not take effect on ports 64-72.
Summit X770 Series Switches
xos0053867 Internal errors occur when looking at egress port qosmonitor after issuing any QoS command such as: enable diffser examination port all, enable diffser replacement port all, disable diffser examine port all, or disable diffser replacement port all:
Slot-1 Stack.34 # sh port 1:93 2:73 qosmonitor Error: Internal error --> no response to stats request for port 1:93.
SummitStack
xos0061799 Precedence order between policy port rules and policy MAC-based rules is not preserved following a master/backup Failover.
xos0062217 In SummitStacks with eight nodes and sFlow configuration, "Hardware L3 Table full" error messages appear when the stacks have a large number of Layer 3 entries.
xos0062700 When upgrading from ExtremeXOS 15.7 or earlier to 16.1, image download fails if image was installed in backup node first and master node second.
xos0062949 HAL process ends unexpectedly in stack after executing the following commands: debug hal configure stacking pdu-trace mask 0xf, debug hal configure stacking pdu-trace capture cap_file
xos0063344 With MLAG and LAG configurations, when a stack node comes up after a reboot, FDB entries flooded from other slots are programmed on incorrect ports internally.
xos0061777 Standby nodes do not come back up to operational state after they go into failed state.
xos0062367 ACL process ends unexpectedly on repeated refresh of ACL policy with clear-flow action.
xos0062522 In SummitStack switches, standby slots go to failed state when a very large number of log messages are continuously generated in the switch.
xos0062800 Stack node fails because of license mismatch for 3rd-party optics.
xos0063242 Stacks configured as DHCP clients do not respond to pinging after failover.
xos0063490 CFM stays down after slot reboot on a stack.
xos0063349 Switch stops responding to SNMP requests if SNMP get for multiple OIDs is continuously initiated.
BlackDiamond 8800 Series Switches
xos0063333 In BlackDiamond 8800 series switches, optics information is not detected and ports remain in "Ready" state after reboot.
xos0063510 ACL rule to deny packets matching L4 match condition stops working if a rule with VID as match condition is appended without an L4 match condition.
xos0057419 On BlackDiamond 8800 series switches, C-series modules reboot after enabling dot1p replacement on ports.
xos0061260 When learning a large number of BGP routes, routes are learned first in route table, rather than LOCAL-RIB. No routes are learned to RIB until all routes are learned in route table. All prefixes are learned in route table, and only then are all prefixes are learned to LOCAL RIB.
xos0062009 In BlackDiamond 8800 series switches with XL modules, clearing FDBs when there is a loop causes the FDBs to lose synchronization across slots or switching units.
xos0062535 On BlackDiamond 8900-10G24Xc I/O modules, packets are dropped by ACL rules with "redirect-port-list" action.
xos0063872 After multiple executions of run failover with redirect-flow configuration, IPv4 ping fails.
xos0063532 IGMP report packets are not processed when received on VMAN CEP port.
BlackDiamond X8 Series Switches
xos0060666 After failover, traffic gets flooded on the ports of service VLAN in H-VPLS core.
xos0061639 Packets ingressing on VLAN-bridged interfaces (Layer 2 VLANs) are not forwarded when the destination MAC address is the same as the switch MAC address, and the switch has at least one Layer 3 interface.
xos0061902 BlackDiamond X8 series sw