Resolved Issues in ExtremeXOS 16.2

The following issues were resolved in ExtremeXOS 16.2. ExtremeXOS 16.2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, and ExtremeXOS 16.1.3. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 16.2

CR Number Description
   
xos0064215
The following log message appears when a subnet is reachable both using MPLS and non-MPLS:
<Warn:Kern.IPv4FIB.Warning> Slot-4: dest 0x0A420000 / 24  nexthop 0xAC11121E: Unable to add route to unit 1, rc Entry not found.  Shadow problem. 
Summit X430 Series Switches
xos0059486 On Summit X430 series switches, optics are not detected after repeated removal and reinsertion of optics when CPU is busy.
xos0064084 In Summit X430 series switches, the command show power details displays fan status as "empty".
Summit Series Switches
xos0059007 QSFP+ to SFP+ adapter support is added to work with all optical SFP+ transceivers with the exception of LRM and passive copper direct attach cables.
xos0059484 Gigabit Ethernet compliance value is shown as "UNKNOWN" for BXU/D optics. Also, DDMI values do not appear. Media Type appears as "NONE" in show ports configuration command.
xos0059508 Link does not come up when 1G BX U/D optics are inserted into 10G SFP+ ports.
Note: Configure the port for speed 1,000 with auto-negotiation “on” using the command configure port <> auto on speed 1000 duplex full. For Summit X670V switches, remove and then re-insert the optics. For all Summit switches, except the X670V, the corrected behavior persists even after rebooting. For Summit X670V switches after rebooting, the transceiver must be removed, and then re-inserted.
xos0062570 In SummitStacks, executing the command enable sflow ports all enables sFlow inappropriately on stacking ports.
xos0062821 ACL rules installed are not mapped to single virtual group even though ACL action-resolution mode is highest-priority.
Summit X440 Series Switches
xos0060466 RX CRC errors with traffic loss occur when “CBL, SFPP, PASSIVE 10GB-C10-SFPP, 10M" from Tyco is inserted into Summit X440-48t-10G switches SFP+.
xos0062362 On Summit X440-24t series switches, process rtmgr pid 1572 ends unexpectedly with signal 11 error after disabling BGP with compressed routes.
xos0062621 On Summit 440-8p switches, the show fan command output displays that the fan is unsupported.
xos0063627 ARP is not re-added to hardware after it is removed initially due to the table being full.
xos0064050 While running diagnostics on a Summit X440 10G model switch with revision 10 and diagnostics test version 6.0 or above, "Test loopback phy fiber" and "Test snake interface" fail.
Summit X440-G2 Series Switches
xos0063317 When policy is enabled one less than the max number of netlogin users can be handled per slot.
xos0062775 With 32 Up MEPs configured, saving and rebooting produces the following errors:
10/03/2015 18:14:06.81 <Noti:EPM.system_stable> System is stable. Change to warm reset mode
 10/03/2015 18:14:10.06 <Info:HAL.IPv4ACL.Info> Synching ACLs to Switch
 10/03/2015 18:14:10.35 <Info:HAL.IPv4ACL.Info> Done synching ACLs to Switch
 10/03/2015 18:15:11.73 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:33, 12, 33) - pibAclWrapInstall(1, 2, 1020, 5242950) returned "Table full".
 10/03/2015 18:15:11.77 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:33, 13, 33) - pibAclWrapInstall(1, 2, 1021, 5242950) returned "Table full".
 10/03/2015 18:15:13.26 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:5, 12, 33) - pibAclWrapInstall(1, 1, 1028, 5242950) returned "Table full".
 10/03/2015 18:15:13.30 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:5, 13, 33) - pibAclWrapInstall(1, 1, 1029, 5242950) returned "Table full".
 10/03/2015 18:15:15.47 <Info:HAL.Card.Info> Switch is operational
Summit X450-G2 Series Switches
xos0060129 On Summit X450-G2 series switches, 10/100/1000BASE-T SFP+ optics do not link to similar optics when in the SFP/SFP+ ports. They do link or partially link when connected to a regular triple speed copper port.
Summit X460 Series Switches
xos0063206 Cannot add L2 entries in hardware due to a full L2 table caused by hash collisions.
xos0063595 On Summit X460 series switches, the command to configure stacking ports does not show the native option.
xos0063948 Clearflow delta values are randomly not calculated properly.
Summit X460-G2 Series Switches
xos0060018 With a 0.5M, 40G QSFP MOLEX passive copper cable inserted, disabling the port where the optic is inserted, rebooting, and then enabling the port, the port stays in the ready state and doesn't come up as enabled.
Note: Remove and re-insert the optics. The port then comes up as enabled.
xos0061486 Combo ports have unsupported autonegotiation and half-duplex settings.
xos0062855 On the Summit X460-G2 series switches, VPLS packets are forwarded with two tags when the service VLAN ports are also members of an untagged VMAN.
xos0062913 On Summit X460-G2 series switches, copper combo port does not advertise its flow control capabilities to peers.
xos0063495 Policy authentication fails when RADIUS request queue has stale entries.
xos0063811 Summit X460-G2 series switches with ExtremeXOS 15.6 through 21.1, have the following limitations for SyncE input reference frequency:
  • Network clock does not lock with input SyncE source port 52 (both at 10G and 1G speed) on all 48-port models (X460-G2-48t, 48x and 48p).
    Note: For SyncE input at 10G, avoid port 52.
  • When the 10G ports operate at 1G speed, the network clock does not lock. Models with Ethernet BASE-T or Power over Ethernet (PoE) ports may lock on initial configuration, but do not lock after a save and reboot.
    Note: For SyncE input at 1G, use a 1G port, not a 10G port.
Summit X480 Series Switches
xos0054290 When a semicolon is missing from ACL matching criteria, the ACL process ends unexpectedly.
xos0060614 When exporting OSPF routes into BGP, and long policy name causes process dcbgp pid 1575 to end unexpectedly with signal 11.
xos0061251 For Summit X480, X460, X440, X430 series switches, and E4G-200 and E4G-400 cell site routers, Dot1p examination functionality does not work correctly for untagged ports when diffserv examination is enabled on those ports.
Summit X670 Series Switches
xos0060656 Link does not come up when 1G BX U/D optics are inserted into 10G SFP+ ports.
Note: Configure the port for speed 1,000 with auto-negotiation “on” using the command configure port <> auto on speed 1000 duplex full. For Summit X670V switches, remove and then re-insert the optics. For all Summit switches, except the X670V, the corrected behavior persists even after rebooting. For Summit X670V switches after rebooting, the transceiver must be removed, and then re-inserted.
xos0061167 Links become active without a connection with tri-speed Base-T SFP installed.
xos0061559 Enabling OpenFlow on VLANs causes double-wide ACL slice to be used even though it can fit in single-wide slice.
xos0063052 Traffic loss occurs on computer connected to Summit X670v-48t switches when the connected switch port is oversubscribed in 100 MB mode.
xos0063137 Known unicast traffic is not shared between the stacking high-gig trunk ports.
Summit X670-G2 Series Switches
xos0061791 On SummitStacks containing master and standby nodes of different switches, the standby node may go to failed state after a node reboot.
xos0062166 On Summit X670-G2 series switches configured with L3VPN, executing the clear iparp command causes the switch to reboot with Kernel Oops.
xos0063204 Traffic stops on LAG ports when frequently modifying the sharing group.
xos0063807 On Summit X670-G2 series switches, egress ACL rule actions do not take effect on ports 64-72.
Summit X770 Series Switches
xos0053867 Internal errors occur when looking at egress port qosmonitor after issuing any QoS command such as: enable diffser examination port all, enable diffser replacement port all, disable diffser examine port all, or disable diffser replacement port all:
Slot-1 Stack.34 # sh port 1:93 2:73 qosmonitor Error: Internal error --> no response to stats request for port 1:93.
SummitStack
xos0061799 Precedence order between policy port rules and policy MAC-based rules is not preserved following a master/backup Failover.
xos0062217 In SummitStacks with eight nodes and sFlow configuration, "Hardware L3 Table full" error messages appear when the stacks have a large number of Layer 3 entries.
xos0062700 When upgrading from ExtremeXOS 15.7 or earlier to 16.1, image download fails if image was installed in backup node first and master node second.
xos0062949 HAL process ends unexpectedly in stack after executing the following commands: debug hal configure stacking pdu-trace mask 0xf, debug hal configure stacking pdu-trace capture cap_file
xos0063344 With MLAG and LAG configurations, when a stack node comes up after a reboot, FDB entries flooded from other slots are programmed on incorrect ports internally.
xos0061777 Standby nodes do not come back up to operational state after they go into failed state.
xos0062367 ACL process ends unexpectedly on repeated refresh of ACL policy with clear-flow action.
xos0062522 In SummitStack switches, standby slots go to failed state when a very large number of log messages are continuously generated in the switch.
xos0062800 Stack node fails because of license mismatch for 3rd-party optics.
xos0063242 Stacks configured as DHCP clients do not respond to pinging after failover.
xos0063490 CFM stays down after slot reboot on a stack.
xos0063349 Switch stops responding to SNMP requests if SNMP get for multiple OIDs is continuously initiated.
BlackDiamond 8800 Series Switches
xos0063333 In BlackDiamond 8800 series switches, optics information is not detected and ports remain in "Ready" state after reboot.
xos0063510 ACL rule to deny packets matching L4 match condition stops working if a rule with VID as match condition is appended without an L4 match condition.
xos0057419 On BlackDiamond 8800 series switches, C-series modules reboot after enabling dot1p replacement on ports.
xos0061260 When learning a large number of BGP routes, routes are learned first in route table, rather than LOCAL-RIB. No routes are learned to RIB until all routes are learned in route table. All prefixes are learned in route table, and only then are all prefixes are learned to LOCAL RIB.
xos0062009 In BlackDiamond 8800 series switches with XL modules, clearing FDBs when there is a loop causes the FDBs to lose synchronization across slots or switching units.
xos0062535 On BlackDiamond 8900-10G24Xc I/O modules, packets are dropped by ACL rules with "redirect-port-list" action.
xos0063872 After multiple executions of run failover with redirect-flow configuration, IPv4 ping fails.
xos0063532 IGMP report packets are not processed when received on VMAN CEP port.
BlackDiamond X8 Series Switches
xos0060666 After failover, traffic gets flooded on the ports of service VLAN in H-VPLS core.
xos0061639 Packets ingressing on VLAN-bridged interfaces (Layer 2 VLANs) are not forwarded when the destination MAC address is the same as the switch MAC address, and the switch has at least one Layer 3 interface.
xos0061902 BlackDiamond X8 series switches use VLAN instance as index instead of router interface (rtif) for ARP entries.
xos0062200 BGP is not converging when there is change in network in scaling environment. When the best path goes down, BGP RIB converges. but route table is still showing old peer as gateway.
xos0062262 UDP profile configurations on VLANs do not take effect in BlackDiamond X8 series switches.
xos0062306 Packets get reflected with same tag on port-specific, tag-enabled VLANs after failover. Issue happens only on switches having both port-specific tags and MPLS RSVP-TE configurations.
xos0062477 BlackDiamond X8 series switches’ management ports flap and show "Detected Tx unit hung" error messages.
xos0062499 Multicast packets are dropped in Layer 2 bridged VLANs.
xos0063546 The following error message may appear when BlackDiamond X8 modules are rebooted after configuring port partition:
<Erro:Kern.Card.Error> Slot-2: _setSchedMode: u:p=1:006 schedMode=1 err=Invalid parameter
xos0063928 In BlackDiamond X8 series switches, Sysuptime in sFlow packets is invalid.
xos0063958 BDX8-40G12X-XL module goes into reboot cycle if any physical loop is configured or a network loop is present on the module.
xos0064010 The command show port buffer displays an incorrect port range for 100G I/O modules.
General
xos0063554 The following vulnerability in OpenSSL exists that impacts ExtremeXOS (CVE-2015-3197): A malicious client can negotiate SSLv2 ciphers that have been disabled on the server and complete SSLv2 handshakes even if all SSLv2 ciphers have been disabled, provided that the SSLv2 protocol was not also disabled via SSL_OP_NO_SSLv2. This issue affects OpenSSL versions 1.0.2 and 1.0.1.
xos0061745 Ampersand used in UPM script is replaced by "& amp" in the XSF configuration.
xos0061841 FDB entries are not learned again after limit learning is unconfigured, and then configured again, with PSTAG configuration in SummitStacks.
xos0061943 MPLS process ends unexpectedly when get-next is done with incomplete OID for mplsXCIndex.
xos0062850 When upgrading ExtremeXOS to 15.7 or later releases, the web HTTP access is enabled even though it is disabled in the configuration.
xos0063028 RADIUS configuration with shared-secret of 32 character is lost after reboot.
xos0063248 NTP MD5 authentication with NTP server is failing.
xos0063257 Saving configuration fails/times-out when VLANs added to a mirror filters are renamed.
xos0063271 Layer 3 packets in non-default virtual routers are slow-path forwarded after disabling MPLS in the peer switch.
xos0062255 CEP CVID configurations is missing after adding/deleting the port from sharing.
xos0062720 Unable to save configuration when ACL/CFM is configured on multiple VLANs.
xos0057931 After rebooting the switch multiple times, the following error log message appears:
<Erro:cm.loadErr> Failed to load configuration: timed out (after 150 seconds) while waiting for all applications to get ready to load configuration on OPERATIONAL ( eaps is still not ready yet).
xos0061788 The process devmgr ends unexpectedly during snmpwalk when continuous EMS logs are sent to the switch console.
xos0062271 CLI memory leak occurs when executing show commands with include option through script.
xos0064043 Unable to use a configuration file that has been copied from an existing configuration file.
xos0064179 MAC movement occurs in switch acting as an STP root bridge when PVST+ BPDUs are sent by peer switch using STP blocked port.
xos0062366 After rebooting, DHCP binding entries are not restored using vr-default.
xos0057231 An FDB entry created by ARP with "i" flag set is not removed from the FDB table after a static entry for the same IP address is added with a different MAC value.
xos0063521 A few IBGP routes are not updated in routing table when disable bgp and enable bgp commands are executed in quick succession.
xos0064203 Incorrect next hop is choosen by BGP route after port flap.
xos0062441 The process rtMgr ends unexpectedly when IPv6 static route is deleted.
xos0060319 Trying to create the maximum number of Layer 3 VLANs causes the following error messages to appear:
02/20/2015 11:37:34.18 <Erro:HAL.VLAN.Error> MSM-A: pibVlanInstallBatchFilter(): Internal error while translating IPv6MC Ctrl Port filter id on Slot  2, unit 13.
 02/20/2015 11:37:34.18 <Erro:HAL.VLAN.Error> MSM-A: Failed to install IPV6 Link-Local MC Control Packet Filter for the port 2:24 (Conduit failure)
 02/20/2015 11:37:34.18 <Erro:HAL.VLAN.Error> MSM-A: pibVlanInstallBatchFilter(): Internal error while translating IPv6MC Ctrl Port filter id on Slot  2, unit 13.
 02/20/2015 11:37:34.18 <Erro:HAL.VLAN.Error> MSM-A: Failed to install IPV6 Link-Local MC Control Packet Filter for the port 2:48 (Conduit failure)
xos0062265 Some legacy commands are not recognized.
xos0062277 The command show vlan vlan_list does not show information for dynamic VLANs nor the Default VLAN. Error appears.
xos0062427 EDP process ends unexpectedly when CDP packets without portId TLV are received.
xos0058750 Neighbor discovery packets are duplicated in L2 VLANs when IPv6 addresses are configured for other VLANs that do not have any ports.
xos0062240 Port that was administratively disabled becomes up after enabling rx pause.
xos0061506 In Summit X440-G2 and X460-G2 series switches, the combo port comes up as active even though when link peer port is down.
xos0063255 In Chalet, VLANs are sorted incorrectly..
xos0064447 Creation of user accounts through XML does not work.
AAA
xos0064307 RADIUS accounting configuration is incorrect as shown by the command show conf aaa and is lost after upgrade.
ACL
xos0062537 HAL crash occurs when redirect-port-list action contains more than 64 ports.
xos0062619 SSH access-profile using policy does not work with IPv6 addresses.
xos0063082 Updated DSCP value is not refreshed for Dynamic ACLs.
xos0063172 ACL action "redirect-port-list" does not take effect when another slice has a rule to match all packets with deny action.
xos0063240 ACL process ends unexpectedly when switch has clear-flow ACL rule with count interval greater than snmptrap generation timer.
xos0064054 SNMPwalk on extremeAclStatsTable returns value with port instance instead of ifIndex.
xos0064223 Need to add an ACL match condition for matching next-hop addresses during the look-up cycle of a packet, so that actions can be taken based on the next-hop a packet is destined for.
xos0064490 After upgrading from ExtremeXOS 15.2 to later release, last installed dynamic ACL rule is given more priority than previously installed rules.
xos0062145 With QoS configuration, ACL process signal 11 ends unexpectedly after rebooting.
xos0063547 Process ACL ends unexpectedly after applying a policy file with source zone as a match condition.
xos0064129 Policy refresh never completes with network-zone configuration.
AVB
xos0062494 Source MAC addresses learned through MVRP packets on a blocked port (STP) cause traffic to be dropped.
BGP
xos0055051 When applying an import policy to BGP, cost configured in the policy is not applied to route tables. This issue is not resolved after multiple policy refreshes nor after multiple disabling, and then enabling BGP.
xos0058441 After creating a BGP peering session between link local IPv6 addresses with the scope ID specified, deleting the VLAN containing link local IPv6 address. and then issuing the command show configuration bgp, switch reboots with “Epm application wdg timer warning” error message.
xos0061129 In a multi-peer setup with many routes (over 150K), a few routes from the preferred peer do not become active in the BGP RIB. Disabling, and then re-enabling peer, restores all routes.
xos0061411 Route table installs sub-optimal BGP routes (next-hop) to kernel, while the BGP RIB shows different paths when same routes are received from two different peers in local-RIB
Note: Disable, and then enable peer or disable, and then enable BGP.
xos0061505 After a topology change in the network, BGP routes requiring two levels of recursive lookup are programmed in hardware with incorrect next hops.
xos0063173 Process dcbgp ends unexpectedly with signal 11 after issuing the command show bgp neighbor.
xos0064319 Aggregated BGP route is not transmitted to upstream neighbor when highest prefix route is received from neighbor.
xos0064589 While learning BGP routes, some routes are not getting installed in route table when deleting and re-adding the static route.
xos0062260 BGP process ends unexpectedly when local address or password is changed for BGP neighbor, and then you immediately execute a BGP show/configuration command.
xos0064496 BGP route policy performs improper community delete operation.
CFM
xos0063506 Traceroute MAC address in CFM domain does not return information about destination switch.
ClearFlow
xos0062629 Clearflow rule does not work properly if there is dot(.) in the ACL counter.
Clocking
xos0063370 PTP Delay Response correction field contains high value (random value) when PTP Delay response packets are passing through combo ports.
xos0062504 You can set a GPTP "peer delay current interval" outside of the correct range of -3 to 17..
Devices
xos0063429 The output of the command show fan shows the fan status as empty after a hot re-seating of the fan module.
xos0062879 Transceiver information shows same Rx power value for 4x10G partition ports even though some ports are in ready state.
xos0064075 The output of the show fan command shows fan status as "Failed" after hot re-seating a fan module.
DHCP/BOOTP
xos0058668 After rebooting DHCPv6, client remains in rebooting state.
xos0058669 DHCPv6 client: After changing the client identifier type, and then restarting the port, old IPv6 addresses are not released, causing the show vlan command to show multiple IPv6 addresses.
xos0061219 Parallel-mode-enabled DHCP offer is sent using primary IPv4 address to the client for multiple offers received from server for different IPv4 addresses.
xos0062017 DHCP trusted port configuration is lost after disabling, and then re-enabling LAG.
xos0064151 Error occurs when removing DHCP configuration from VLANs when LAG ports are added to the VLANs.
EAPS
xos0063282 ExtremeXOS CLI restricts PVLAN subscriber VLAN from being configured as an EAPS-protected VLAN.
EDP
xos0062472 Source MAC addresses learned through CDP packets received on EAPS-blocked ports cause traffic to be dropped.
ELRP
xos0062460 The show configuration command output shows incorrect ELRP configuration.
xos0062618 ELRP forgets the disabled port information if the port is deleted from another VLAN that also has ELRP enabled. As a result, the disabled port stays disabled unless manually enabled.
EMS
xos0063736 In Syslog, username information appears as "*****" during login/logout cases.
ESRP
xos0061965 Configuring ESRP member VLANs (VRRP-enabled) produces errors.
FDB
xos0062789 Disabling learning on LAG ports does not flush FDB entries.
xos0063368 In an MLAG configured switch, FDBs are not installed in hardware after reboot if there are frequent MACMoves between MLAG port and ISC.
xos0059481 Static FDB is programmed incorrectly in hardware after a stack failover.
Identity Management
xos0061781 Identity manager entries become stale when clients are moved from one port to another in sub-VLANs.
IGMP
xos0062914 The process mcmgr ends unexpectedly after receiving corrupted IGMPv3 join packets on MLAG ports.
ISIS
xos0063423 Memory leak occurs in ISIS process when exporting OSPF routes to ISIS.
Layer 2
xos0064682 Enabling egress VMAN CEP filtering on a CEP port sends a tagged packet, even though it should be forwarded as untagged.
Layer 3
xos0062710 On BlackDiamond 8800 or BlackDiamond X8 series switches, with Distributed IP ARP mode on, ECMP routes are sometimes not installed when gateways flap.
Multicast
xos0063245 With IGMP per-VLAN mode, VRRP flaps occur after adding tagged ports to VLANs.
xos0064519 With MVR enabled on two VLANs, IGMP report packets are looped if sent to all hosts group.
xos0062705 Kernel oops can occur after clearing IPMC FDB in a stack.
xos0064357 Out of sync between PIM and RTMgr process after introducing new best route.
LACP/LAG
xos0062428 Member ports with a modified speed configuration that is different than the master port should not be allowed in LAG.
xos0063134 Traffic stops after disabling, and then enabling LAG porst having pstag with static FDB.
xos0064326 LACP flaps when the LAG ports are added to VMANAs, with the VMAN ether type same as LACP ether type.
MLAG
xos0064009 MLAG+EAPS:Traffic forwarding stops after EAPS that include ISC link converges.
xos0064067 Traffic loss occurs in MLAG setup when ingress port and ISC port reside on different hardware units, and when the internal port number for both of these ports is the same.
xos0056368 Kernel errors occur after disabling sharing configuration on ISC ports of MLAG. For example: "exvlan: handleVsmKernelRequest:8545: handleVsmKernelRequest Invalid Ingress port: 1000008 got"
NetLogin
xos0061433 extremeNetloginUserLogoutTrap is received with errors.
xos0061868 With protocol order as MAC dot1x, web-based UPM profile is not executed for the client, which is authenticated as MAC.
xos0062674 UPM profile fails to set the variables received from the RADIUS server using VSA 212.
xos0063090 NetLogin client does not move into authfail VLAN when user is absent from local database.
Optics
xos0063120 Error message "CFP2 modules >= 18 W unsupported" incorrectly appears for Finisar Corp CFP2 LR4 optics.
OSPF
xos0061855 Configured OSPF neighbor is not retained after rebooting.
Policy  
xos0062965 Policy process ends unexpectedly with signal 6 when master node goes down.
QoS
xos0062050 QoS committed rate configurations for port groups are not loaded properly after a save and reboot.
xos0061027 For SummitStacks, creating or deleting non-default QoS profiles may cause some ports to flap.
RSVP-TE
xos0062380 Switch rejects incorrect LSP configurations as expected, but this operation still uses LSP indexes in hardware.
Sflow/Netflow
xos0063418 No mapping for Modid errors occur when sFlow is enabled on the port.
SNMP
xos0057269 SNMP trap extremeIpSecurityViolation is sent with incorrect VLAN description.
xos0061507 SNMPget on EXTREME-SOFTWARE-MONITOR table returns value with incorrect OID.
xos0057212 SNMP traps not sent after changing or saving configuration, even though respective traps are enabled.
xos0063332 Configuration changes to VPLS are not fully retrieved by SNMP walk, which returns values for only few VPLS index.
SSH
xos0059942 SSH connection ends when show commands produce lengthy output.
STP
xos0057785 STP domain tag is removed when all ports are deleted from STP auto-bind enabled-VLANs.
xos0062133 STP flush event does not happen after ports are quickly disabled, and then enabled.
xos0062290 Due to ExtremeXOS reflection RSTP BPDU support, upstream bridges believe that they are receiving their own BPDUs (contain the bridge's ID), thus causing multisource events during topology changes, which can cause slow convergence times when lp is configured (upwards of 30 seconds).
xos0063457 Configuration for adding network VLAN port in STP for subscriber is not saved.
xos0063484 Enhancement added in STP flush generation mechanism to reduce hardware programming load.
xos0064395 STP digest value gets changed when adding the port in VLAN or removing the port from VLAN.
xos0062701 HAL timeout occurs while rebooting a stack with STP configuration.
VLANs
xos0063331 VLAN IP address is unconfigured when modifying the VLAN name/port information from Chalet.
xos0063186 Kernel oops occurs when deleting private VLAN.
VMANs
xos0063274 VLAN packets are egressing with VMAN ethertype when an egress port is deleted from a VMAN that is also part of a VLAN.
xos0063207 Error occurs while adding LAG ports as tagged in one VMAN and untagged in another VMAN, even though the VMAN EtherType is primary.
VPLS/HVPLS
xos0064033 In BlackDiamond X8 and Summit X670 series switches, traffic gets software forwarded after disabling/enabling members of a shared group and recreating the shared group after deletion.
xos0059596 Can add more than one LSP a pseudo-wire when it is associated with a VPWS.
xos0061092 Traffic forwarding on VPLS-serviced VMAN stops after link flap.
xos0062045 LLDP packets are tunnelled over L2VPn.
xos0062754 VPLS traffic egresses out with dot1q tag when secondary EtherType is configured.
xos0063842 Packets are being flooded in both network and access VLAN ports after port flap.
VR/VRF/L3VPN
xos0062128 L3VPN traffic is not forwarded after executing disable port and enable port in MPLS core network.
xos0052723 With L3VPN configured (also: OSPF, BGP, MPLS, LSP) and routes are being advertised and installed in the VRF routing table, after restarting process OSPF, VPN routes are not installed.
xos0061198 Disabling VPN-VRF affects traffic on another VPN-VRF.