Resolved Issues in ExtremeXOS 21.1.2

The following issues were resolved in ExtremeXOS 21.1.2. ExtremeXOS 21.1.2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3 and ExtremeXOS 21.1.1. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 21.1.2

CR Number Description
General
xos0055511 While configuring STP (802.1d) with port-encapsulation mode as EMISTP where the L2PT-enabled VMAN and access VLAN have the same tag, the designated bridge is not accepting the L2PT tunneled BPDUs from the root bridge, and thus causes a loop (designated bridge also becomes a root bridge).
This problem does not occur:
  • When the access VLAN's tag and the L2PT-enabled VMAN's tag are different.
  • Without any L2PT configured, with the same tag used for the access VLAN and provider-edge VMAN.
  • When using Per-VLAN Spanning Tree Plus (PVST+), regardless of same or different tags.
xos0058668 After rebooting DHCPv6, client remains in rebooting state.
xos0061359 Policy has no PVID after unconfiguring the switch.
xos0062850 When upgrading ExtremeXOS to 15.7 or later releases, the web HTTP access is enabled even though it is disabled in the configuration.
xos0063183 Chalet's web login requires RADIUS Netlogin to be enabled for RADIUS authentication to succeed when only Mgmt-Access should be required.
xos0063190 Session timeout value is inappropriately overwriting the idle time-out value whenever both session timeout and idle timeout values are same, or the idle timeout value is 0.
xos0063331 VLAN IP address is unconfigured when modifying the VLAN name/port information from Chalet.
xos0063554 The following vulnerability in OpenSSL exists that impacts ExtremeXOS (CVE-2015-3197): A malicious client can negotiate SSLv2 ciphers that have been disabled on the server and complete SSLv2 handshakes even if all SSLv2 ciphers have been disabled, provided that the SSLv2 protocol was not also disabled via SSL_OP_NO_SSLv2. This issue affects OpenSSL versions 1.0.2 and 1.0.1.
xos0064029 Cannot delete prefixes for VLAN router advertisement messages after setting them.
xos0064043 Unable to use a configuration file that has been copied from an existing configuration file.
xos0064100 With policy enabled, switch reloads with kernel oops when deleting a port from a VLAN that also has the same port added to PSTag.
xos0064216 Unable to ping a destination which is reachable, if the destination is also present locally but disabled.
xos0064220 Calling-station-id attribute is missing in the RADIUS request for mgmt-access.
xos0064240 No log message appears by default when a BGP peer transitions to established or from the established state.
xos0064436 When adding ports to VLAN from Chalet, IPforwarding gets disabled for that VLAN.
xos0064447 Creation of user accounts through XML does not work.
xos0064459 Nettools process ends unexpectedly with signal 11 when processing router advertisement packets with DNSSL option.
xos0064682 Enabling egress VMAN CEP filtering on a CEP port sends a tagged packet, even though it should be forwarded as untagged.
xos0064863 Hostname is not getting resolved via DNS while initiating SSH/SCP/TFTP from switch.
xos0064956 EDP neighbors are not displayed when remote mirroring is disabled or after unconfiguring a monitor port of remote mirroring.
xos0064960 Multicast traffic is forwarded through MVR receiver port in a VLAN even if there is no active receiver.
xos0065189 BGP secondary best path is not active when primary best path goes down.
Summit Series Switches
xos0058437 For Summit X460 and X670-G2 series switches, the buffer for Weighted Random Early Detection (WRED) queues is incorrectly allocated at 10% of shared memory plus minimum guarantee, when it should be 100% of shared memory plus minimum guarantee.
xos0062972 Add Support for the following optics on Summit X670-G2 and X770 series switches:
  • 10329, 908618-10, 40Gb BiDi QSFP+
  • Avago AFBR-79EBPZ-EX1 optic transceiver
xos0064232 On some systems, after changing a VPWS service VLAN tag, traffic continues to be forwarded with the prior tag.
Summit X620 Series Switches
xos0062729 On Summit X620 series switches, for ports with Base-T SFP optics and explicitly configured at 1,000 speed, link comes up at peer end, but link stays down at local end after either rebooting, or removing, and then re-inserting optics.
xos0062890 On Summit X620 series switches, 100 mbps SFPs (100FX, FX/LX, BASET) fail to link on reboot.
Summit X440-G2 Series Switches
xos0062583 Policy: Dynamic VLAN is not removed from backup slot after issuing unconfigure policy maptable.
Summit X460-G2 Series Switches
xos0063811 Summit X460-G2 series switches with ExtremeXOS 15.6 through 21.1, have the following limitations for SyncE input reference frequency:
  • Network clock does not lock with input SyncE source port 52 (both at 10G and 1G speed) on all 48-port models (X460-G2-48t, 48x and 48p).
  • When the 10G ports operate at 1G speed, the network clock does not lock. Models with Ethernet BASE-T or Power over Ethernet (PoE) ports may lock on initial configuration, but do not lock after a save and reboot.
xos0063960 Several help options do not appear for the show fdb command.
Summit X670-G2 Series Switches
xos0064568 Traffic drop occurs on VPLS service VLANLAG port after slot reboot.
xos0064537 Randomly, rtmgr process ends unexpectedly with signal 6 when rebooting neighboring routers with OSPF and BGP routes.
xos0063860 Process rtmgr ends unexpectedly with signal 11 after issuing the command restart ports all in peer switch with BGP enabled.
SummitStack
xos0062753 System-health-check previously ran only on master and backup modules. As a result, any errors on the standby modules of the stack were not checked and reported. The system-health-check process now runs on all ‘operational‘ or ‘alive‘ modules in the stack, including standby modules.
xos0063919 On standby nodes, IP ARP refresh and Neighbor refresh are now disabled on VR-Mgmt. Primary and backup nodes use the configured enabled/disabled setting.
xos0064575 "Operation draining timed out" error message appears while saving the configuration in stacking switch.
ACL
xos0064525 Policy does not allow regular expression to be specified for BGP communities.
xos0064573 ACL process ends unexpectedly after refreshing a policy with clear-flow rules.
BGP
xos006449 BGP route policy performs improper community delete operation.
xos0064884 "remove-private-AS-numbers" setting in BGP is not preserved after switch reboot.
xos0064496 BGP route policy performs improper community delete operation.
MLAG
xos0056368 Kernel errors occur after disabling sharing configuration on ISC ports of MLAG. For example: "exvlan: handleVsmKernelRequest:8545: handleVsmKernelRequest Invalid Ingress port: 1000008 got"
MPLS
xos0063968 HAL process ends unexpectedly after changing/reverting service VLAN tag.
Python
xos0064122 The command show tech-support terminates prematurely when 40G or 100G optics are present in the switch.
SNMP
xos0057212 SNMP traps not sent after changing or saving configuration, even though respective traps are enabled.
xos0064114 SNMP process ends unexpectedly with signal 6 when switch time is modified.
SSH
xos0063347 IPv6 address is not supported in SCP client present in the device.
VLANs
xos0062912 SNMP trap sent for link up/down status change does not include port instance.
xos0063837 After deleting pstag port from a VLAN that has two LAG ports added as untagged, an error message appears.
xos0064094 Removing subscriber VLAN from one PVLAN affects traffic in another PVLAN.
xos0064491 The configuration of a disabled VLAN without any ports does not appear in the output of the show configuration command.
VRRP
xos0063346 With multiple (greater than two) VRRP instances and host-mobility enabled, FDB flush sent during topology change from other L2 protocols does not occur.