The following are new open issues for supported features found in ExtremeXOS 22.2.
Open Issues, Platform-Specific, and Feature Change Requests (CRs)
CR Number | Description |
---|---|
ExtremeSwitching X870 Series Switches | |
xos0066155 | VXLAN dynamic learning for RTEP does not appear in the output of the
show fdb command. Workaround: Save,
and then reboot, the switch. Dynamic FDB entry is created.
|
xos0066307 |
On ExtremeSwitching X870 series switches, IP security features may not work in conjunction with ONEPolicy. Messages similar to the following while enabling either feature may appear: <Warn:ACL.Policy.IntAppConfFail> Failed to install dynamic acl esDhcpSnoop_deny_1 for internal applicaton IpSecurity on vlan client port 23 .Error: ACL install operation failed - filter hardware full for vlan client, port 23. <Erro:Policy.CfgHwRsrcFail> Slot-1: Failed to reserve hardware rules of type unknown. |
xos0066998 | On ExtremeSwitching X870 series switches, not all policy rules are able to be written depending on the order that they are applied. |
xos0066044 | Auto-negotiation at 25G and 50G speeds is not supported on ExtremeSwitching X870 100G ports. Auto-negotiation is disabled by default for 25G and 50G ports. |
xos0068048 | On ExtremeSwitching X870 series switches, i2cenviron test consistently fails
while running diagnostics. Some switches may be missing the diagnostics image. If
so, running diagnostics causes the following error message to
appear:Summit diagnostics xmod is not installed. Please install the diagnostics xmod in order to run diagnostics.Fixing this problem requires installing the onie-22.2.1.5-patch1-4-diagnostics.xmod file to both partitions. |
xos0067183 | On ExtremeSwitching X870 series switches, kernel crash occurs randomly booting up switch with virtual router and mirroring configuration. |
ExtremeSwitching X440-G2 Series Switches | |
xos0066798 | On ExtremeSwitching X440-G2 8-node stacks, stack link convergence time exceeds 700 ms; normal expected convergence time is less than 50 ms. |
Summit X460-G2 Series Switches | |
xos0067064 |
On Summit X460-G2-16mp-32p-10GE4 switches, SyncE does not work on the multi-speed supported ports (1–16). Workaround: SyncE is available
on ports 49–52 (1G/10G) for input, and on ports 17–52 (1G/10G) for
output.
|
xos0067736 | On Summit X460-G2-16mp-32p-10GE4 switches, CRC errors may occur on multi-rate ports (1–16) when running at cold temperatures and while using short cables. |
ExtremeSwitching X620 Series Switches | |
xos0067785 | On ExtremeSwitching X620-16p switches, CRC errors may occur on multi-rate ports (1–12) when running at cold temperatures and while using short cables. |
SummitStack | |
xos0065970 |
On SummitStacks, unable to start process for python module; process name is not recognized: Error: Unknown process name EPM_Other2 |
xos0066776 | On SummitStacks, L2 broadcast traffic sent to 2,048 remote VTEPs is dropped after failover. |
xos0066812 | On SummitStacks of X670G2 or X770 series switches, L2VPN is not supported. |
MPLS | |
xos0066685 | With enable iproute mpls-next-hop configured, LDP adjacencies flap when creating greater than 7,000 pseudowires among 8 or more peers. |
Security | |
xos0066172 | Epm process ends unexpectedly when downloading an ExtremeXOS image with more than one host name. |
VRRP | |
xos0066212 | VRRP flap occurs during state transition when a single VRRP group contains 2,000 IPv6 instances. |