The following are limitations in ExtremeXOS system architecture that have yet to be resolved.
CR Number | Description |
---|---|
General | |
xos0067980 | SSH idle timeout timer is ignored if SSH rekey timer is enabled. |
xos0069068 |
On Summit X770 and X670-G2 series switches with more than 32 IPv4 ARPs, IP unicast
traffic destined to IPv4 addresses residing on port number 64 or higher may not be
forwarded.
Workaround: Either use port numbers 1–63,
or execute configure forwarding internal-tables more l2, and then
save and reboot.
|
Summit X770 Series Switches | |
xos0068553 | The ARP learning rate on the Summit X770 series switches has decreased starting with ExtremeXOS 22.2 due to code infrastructure changes. |
ExtremeSwitching X690 Series Switches | |
xos0067697 | On ExtremeSwitching X690 series switches, Tri-speed (10/100/1000 BaseT) BASET optic is not supported. |
xos0068281 | On ExtremeSwitching X690-48t copper ports, EAPS convergence time is greater than 100 milliseconds. |
SummitStack | |
xos0066970 | In the output of the show fan command, the fan tray revision and part number appears only for first fan tray in stack. |