Resolved Issues in ExtremeXOS 22.5

The following issues were resolved in ExtremeXOS 22.5. ExtremeXOS 22.5 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, and ExtremeXOS 22.4. For information about those fixes, see the release notes for the specific release.

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 22.5

CR Number Description
ExtremeSwitching X440-G2 Series Switches
xos0071152 ExtremeSwitching X440-G2 stacks when sending CPU-to-CPU traffic experience HG ports to going down randomly..
xos0069919 On ExtremeSwitching X440-G2 SummitStacks, CPU-generated/-forwarded multicast/broadcast packets are not transmitted on ports 25–48 of non-master node.
Summit X450-G2 Series Switches
xos0058653 Flow control capability is advertised even after disabling both Rx and Tx pause
xos0070437 Reboot occurs when DHCPv6 is enabled on Management VLAN when existing DHCPv6 sessions exist on VR-Default.
Summit X460-G2 Series Switches
xos0051464 The command debug hal configure stacking port port# [enable|disable] is not working in stacks.
xos0069055 SNMP times out while reading extremeEntityFRUTable for SFP temperature sensor and the following error appears: entity_fru_getinfo: Invalid entity 612.
xos0070406 Legacy Nortel phones do not power up with Summit X460-G2 series switches using legacy detection mode.
Summit X670-G2 Series Switches
xos0068055 No log messages are provided regarding power delivery or denial.
Summit X770 Series Switches
xos0068355
When scaling to 131,000 VLAN/port combinations, rebooting Summit X770 series switches produces the following error message:
Crit:vlan.err.criticalInfo> Critical Info: Forcing vlan mgr to READY - Timer expired - 1 appls did not send load cfg acks
ExtremeSwitching X690 Series Switches
xos0068848 IPv6 L3 Unicast packets destined to front-panel port 30 are slowpath forwarded instead of hardware forwarded if port 30 is not a member of a load share group.
xos0068870 When using the OE Solutions RBT12SEX-IT3 (MGBIC-BX40-U) and RBT12SEX-IT4 (MGBIC-BX40-D) transceivers, the command show port configuration displays a media type of "NONE".
xos0068871 When using the OE Solutions RBT12SVX-IT4 (MGBIC-BX120-U) and RBT12SVX-IT5 (MGBIC-BX120-D) transceivers, media type appears as "NONE" when issuing the show port configuration command.
xos0070521 Mirroring does not work on ExtremeSwitching X690 series switches when mirroring configuration is set up prior to insertion of cable or optics in monitor port.
xos0070593 On ExtremeSwitching X690 series switches, rarely, AAA process gets restarted after configuring clear text shared secret password for RADIUS.
xos0070731
On ExtremeSwitching X690 series switches, FIPS error messages appear when configuring the clear text shared secret for RADIUS:
Error: FIPS_mode_set(1) failed. Reason: error:24064064:random number generator:SSLEAY_RAND_BYTES:PRNG not seeded
 Given key is not a valid encrypted key. Please provide a valid encrypted key that is encrypted by the switch. Legacy Set Failed for index 2147483644 
ExtremeSwitching X870 Series Switches
xos0070825 When ARPs use the extended hash table, the packets that are forwarded using these ARP entries contain incorrect MAC addresses.
xos0071371 BCMAsync process ends unexpectedly with signal 6 when modifying extended view ARP entry to LAG port.
General
xos0067374 Display exact primary/secondary image versions (including patch info) in show switch similar to one that is displayed by show version image.
xos0070635 Switch configurations made through Extreme Management Center or SNMP do not persist through a reboot.
xos0052545 During failover from EBGP to VPNv4 IBGP route, VPNv4 IBGP route is removed causing loss in connectivity over L3VPN.
xos0070016 IP route compression is enabled automatically after configuring an IP address in a VLAN created over user VR.
xos0070213 The command disable/enable ipforwarding broadcast" does not get reflected unless the egress ports are disabled, and then enabled again.
xos0070350 With ping protection configured for the static routes, IP routes are not becoming active.
xos0070498 Kernel crashes randomly after learning FDB entries with the port instance of VLAN as null.
xos0070592 OSPF neighborship is not re-established after configuring IP multicast forwarding option "to-cpu" to off, and then back on, over the LAG port in VLAN.
xos0071021 HAL process ends unexpectedly due to memory corruption with eFence is enabled.
xos0070566 Unnecessary LLDP debug messages appear on switch console when Fabric Attach neighbor is added.
xos0071340 In the output of show mvrp ports counters event command, MVRP LeaveAll Tx packets appear as Rx packets.
xos0069105 "restconf" and "ping" crash when DNS is enabled.
xos0069372 Chalet, CLI, and SNMP permit different allowed characters for sysName, sysLocation, sysContact.”
xos0061649 Clearing licenses requires a reboot, which if not performed before applying new licenses can cause a switch to crash.
xos0065398 On ExtremeSwitching X690 and X870 series switches stack ports, only 100G passive copper cables are supported.
xos0068766 Diffserv replacement priority and codepoint configurations are not preserved after a save and reboot.
xos0069198 Creating VLANs with reserved keywords using SNMP or Policy Manager is incorrectly allowed.
xos0069688 Chalet muliple authentication approach needs to be combine into a single authentication approach.
xos0069700 SFP+ links are not coming up when connecting with an INTEL Fortville x710 Intel PCI card.
xos0070046 On ExtremeSwitching X690 and X870 series switches, incorrect values appear for cached and buffer memory in top command output.
xos0070786 If jumbo frames are initially enabled on a port, which then becomes a master port of a load-sharing group, followed by enabling jumbo frames on all ports, then in the output of the command show configuration vlan, jumbo-frames are disabled on the slave ports of the load-sharing group.
xos0070819 Information about PSU fan airflow direction needs to be added to the show power command.
xos0069554 On ExtremeSwitching X620 series switches, copper combo port link flaps when SFP+ is inserted in the corresponding fiber combo port. On ExtremeSwitching X440-G2 and Summit X460-G2 series switches, copper combo port link flaps when SFP is removed from the corresponding fiber combo port.
xos0068900 On the Summit X460-G2, X450-G2, and X480 series switches, FDB entries are not removed in software and hardware after FDB aging time expires.
ACL
xos0070419 In the ExtremeXOS User Guide ACL chapter, applicable direction for source/destination port range needs to be updated.
xos0070672 HAL process ends unexpectedly when executing show access-list counter after refreshing a user-created policy.
xos0070775 HAL process ends unexpectedly when executing the configure access-list delete acl_name all command after refreshing the ACL.
xos0071294 On ExtremeSwitching X440-G2 and X620 series switches, rules with more than two "l4-match" statements do not install in single-wide mode (or more than "l4-match" statements in double-wide mode).
AVB
xos0068199 The AVB protocols provide limited EMS log messages for troubleshooting and debugging.
BGP
xos0066333 BGP session remains in IDLE state when BFD is enabled for peer.
xos0067516 When two ingress policies with same number for as-path length is added to BGP peer, route table is not learning as multipath route, whereas BGP learns as multipath.
Clocking
xos0070525 Grandmaster clock change takes an excessive amount of time to propagate in a cascade network.
DHCP/BOOTP
xos0063125 DHCP option 82 check for circuit ID is not working properly with client-connected VLANS that have multiple ports with one port configured with circuit ID string and the other without a circuit ID string configured.
xos0064448 After unconfiguring a switch and loading a script with two DHCPv6 clients, only one client gets an IPv6 address and the other remains in initializing state.
xos0065271 DHCP Relay with option 82 check fails if the client is connected by a LAG port, is on a different slot, and has port information string configured.
xos0068326 L3 routing is not working after rebooting an interface that received IP address from DHCP server.
LAG/MLAG
xos0069566

On an ExtremeSwitching X870/X690 mixed stack, ports 91–96 on any X870 node should not be used.

There are many possible incorrect behaviors possible if ports 91–96 are used on any X870 node in such a stack. Among the known behaviors are L2 Unicast flows received on X690 nodes being unable to reach destinations attached to ports 91–96 on X870 nodes and packet duplication of non-Unicast flows on multiple link aggregation member ports when ports 91–96 on an X870 node are configured as members of a link aggregation group.

xos0070088 With alternate IP address configuration, MLAG ports are disabled when the other MLAG peer comes up after a reboot.
xos0071030 “Ingress Block Port” list is not updated in the kernel for MLAG sharing port after reboot.
xos0071468 In WMLAG, static MAC address of second peer is not flushed from FDB table during failure scenarios.
MPLS
xos0068153 BGP ORF capability enabled while creating BGP peer group.
xos0070035 FDB entry is learned on incorrect service VMAN after a reboot.
xos0070036 FDB entry is learned on incorrect service VMAN after dynamically adding a member port to the LAG.
xos0070427 The command show mpls ldp label retained lsp output should also display the LSR-ID.
MVRP
xos0065119 When an MLAG peer is rebooted, the dynamically added uplink ports on the remote nodes are removed from the VLAN causing traffic loss.
NetLogin
xos0067290 With a low level of continuous traffic, the display of blackholed FDB entries shown by the command show netlogin port x is cleared and not re-set
xos0069806 Number of simultaneous TCP session should be restricted during web-based NetLogin authentication.
xos0069810 NetLogin Dot1x authentication fails if supplicant response is received after EAPOL requests expire.
xos0070165 Timeout error appears in browser when trying to authenticate more than one client in web based NetLogin.
xos0070829 NetLogin mac-list without password added by Extreme Management controller is lost after rebooting the switch.
xos0071373 New TACACS command configure tacacs priv-lvl [optional | required] has been implemented.
OSPF
xos0069475 Changing the OSPFv3 retransmit interval to greater than 2,000, and then restarting OSPFv3 process, removes OSPFv3 interface configuration.
Policy
xos0069875 Warning message that appears when enabling NetLogin MAC in policy mode needs to be removed.
xos0071077 The "tag" match condition is not working with BGP routing policies.
xos0071279 ELRP packets are not flooded to other port of the VLAN that has admin profile configured.
xos0071387 In the ExtremeXOS User Guide Routing Policies chapter, a note regarding "tag" match condition needs to be updated.
Python
xos0069948 When cloning over a network with the reference switch/stack having earlier than ExtremeXOS 22.4 on one partition and later than 22.4 on the other partition, one of the partitions is corrupted.
Security
xos0066530 ARP validation violations are not blocking the port when the client is in subVLAN.
xos0069579 If client port information is missing for some DHCP snooping entries, "FDB lookup failed" errors appear while uploading DHCP bindings.
xos0070601 When the MAC-locking threshold is set to 0, then the learn-limit-action (disable port) is not triggered for the second violation.
xos0071076 The command configure tacacs timeout does not take effect.
SNMP
xos0062492 Traps having tabular variables as varbinds should include the instance along with the tabular OID.
xos0062527 The varbinds of extremePowerSupplyGood, extremePsuPowerStatus traps need to include the instance along with the OID.
xos0066791 The object return value for "extremeStackDetection" is true for stacking, and should be false for a standalone switch, but it does not return any value.
xos0066792 Snmpset is not allowed on read-write object "extremeStackDetection".
xos0067145 extremeSaveConfiguration call causes other SNMP sets to fail.
xos0067627 Q-Bridge MIB object dot1qNumVlans(1.3.6.1.2.1.17.7.1.1.4) incorrectly includes Management VLAN.
xos0067630 Snmpget on dot1qVlanCurrentTable object with 4095 index returns the Management VLAN details when it should only include user VLAN details.
xos0070534 The OID extremeImageToUseOnReboot cannot be used to select the image to be booted on reboot.
SSH
xos0069422 Exiting an SSH client session causes the SSH server to unexpectedly initiate a session close request.
Stacking
xos0070018 In the command show checkpoint-data output, need to show IPML connection status between master and backup in a stack.
xos0070185 Rebooting SummitStack backup node causes BFD process to end unexpectedly while syncing up BFD sessions.
xos0070454 Unable to rename dynamic VLAN created by MVRP.
xos0070754 ExtremeSwitching X440-G2-48 stack reboots while sending IP option packets.
xos0063748 The using the none option in the command configure sys-recovery-level is ignored when you reboot a node stuck in the failed state.
STP
xos0069839 If edge safeguard is enabled on a port before configuring the link type as edge, then the operational edge status of that port becomes false resulting in the port behaving like a normal STP port.
xos0070993 The STP port link-type configuration is not retained when a untagged port is deleted from a VLAN that is part of an STP domain and then added in another VLAN that is also part of the STP domain. This results in the port behaving like a normal STP port, even though the configuration appears in the output of the show configuration stpd command.
xos0071049 STP process ends unexpectedly when deleting STP configuration on a port.
VLAN
xos0069896 Link flaps on multiple ports cause VLAN process utilization to increase excessively.
xos0070503 A source MAC address is re-added on PSTAG ports if the same MAC address is arriving on the master and a member of sharing.
VRRP
xos0071120
After renaming a VRRP VLAN, show vrrp/show configuration commands produce the following error and configuration is lost for other VLANs after a reboot:
Error: VRRP VR for vlan deep, vrid 1 does not exist. Please create the VRRP VR before assigning parameters.