The following issues were resolved in ExtremeXOS 30.3. ExtremeXOS 30.3 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, and ExtremeXOS 30.2. For information about those fixes, see the release notes for the specific release.
Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 30.3
CR Number | Description |
---|---|
General | |
xos0069194 | Packets with size greater than the configured IP-MTU value are forwarded if jumbo frames is enabled and ARP is resolved. |
xos0069987 | HAL process ends unexpectedly with signal 11 when executing the command that fetches entries from hardware. |
xos0072228 | Interface flags in the show ipconfig output do not match the flag values in the show ipconfig vlan-name output. |
xos0073899 | LACP sharing enabled port are added to link aggregator even though port speeds are different. |
xos0074117 | When a network is unreachable, ICMPv6 destination unreachable packets are not returned and IPv6 "InNoRoutes", ICMPv6 “DestUnreachs” Out counters are not incremented as shown in the show ipstats ipv6 vlan commmand. |
xos0074200 | The OPNEXT transceiver device does not link reliably on ExtremeSwitching X690, X590, and X465 series switches. |
xos0074661 | The commands enable switch usb and disable switch usb stopped working in the ExtremeXOS 30.1 release. |
xos0074702 | Zero Touch Provisioning (ZTP) does not work over the Management interface. |
xos0074751 | The command clear port <port_list> rate-limit flood out-of-profile status should clear status only. |
xos0074871 | EMS log message should be generated when a port cannot be added to a VLAN. |
xos0074872 | When limit learning is configured on one VLAN, FDB entries on another VLAN are flushed from hardware. |
xos0074874 | Need to permit the use of few special characters for SysName/SysLocation/SysContact. |
xos0074933 | Dynamic VLANs created by MVRP on MLAG ports flap continuously when the ports are in the down state. |
xos0075012 | Need additional configurable option for success count in flow-redirect health check command. |
xos0075021 | HAL process ends unexpectedly when unsupported optics are inserted into the switch. |
xos0075096 | SNMPwalk does not return "partinfo" of all fans present in the switch. |
xos0075175 | After reboot, ports are sometimes not added to the aggregator. |
xos0075202 | Saving the configuration is failing due to IPFIX process. |
xos0075213 | If the debug command debug hal show ipv4Adj is interrupted using "Q" or Ctrl-C before all adjacencies appear, then subsequent Layer 3 hardware updates do not occur. Reboot is necessary to recover. |
xos0075263 | In stacking, LACP ports present in back-up slot are removed/re-added when PSTAG is configured. |
xos0075283 | Enabling NTP from within the VRF is allowed even though it is not supported. |
xos0075433 | Ethernet OAM Rx packet counter does not increment on ExtremeSwitching X465, X590, X690, and X870 series switches. |
xos0075483 | The process cfgmgr ends unexpectedly when executing another save command after a failing first save command. |
xos0075510 | Need to add success option under to command configure flow-redirect next-hop in the ExtremeXOS documentation. |
xos0075937 | Executing Python script produces an ImportError error message when importing files from same directory. |
ExtremeSwitching X465 Series Switches | |
xos0074426 | On ExtremeSwitching X465 series switches with 60W and 90W PoE ports, front panel ports do not match the port numbering on the PoE board. The port number pairs are swapped. The default disconnect precedence is 'deny port' where the highest numbered ports are denied power when the switch's allocated power exceeds its PoE budget. |
xos0075001 | When a slot on a X465 stack with 25G VIM is unconfigured, the ports come up in 40G mode and errors are logged. |
xos0075191 | Layer 2 traffic is not forwarded through the redundant ports between ExtremeSwitching X465 stack and X465 standalone switch. |
ExtremeSwitching X690 Series Switches | |
xos0073818 | Packets originating in a switch fail to egress after removing the ports from service VLAN. |
ExtremeSwitching X870 Series Switches | |
xos0073426 | Unable to configure FEC on X870-96x-8c switch on ports with100G capability enabled through a license. |
ExtremeSwitching X440-G2 Series Switches | |
xos0075020 | Switch takes around 30 seconds to bring up all ports, which is triggering multiple STP topology changes. |
xos0075030 | On ExtremeSwitching X440-G2 48-port switches, ACL hardware full errors occur when Extreme Management Center (XMC) is used to push policy and telemetry. |
xos0075129 | IPv6 MLD packet filter installation fails in ACL double-width mode. |
xos0075492 | ExtremeSwitching X440-G2 series switches PoE virtual temperature sensor model algorithm needs correction. |
Summit X460-G2 Series Switches | |
xos0075787 | Port stays in the loop-back state after upgrading the standalone switch to stack. |
ACL | |
xos0074626 | In Policy, traffic is flooded on ports even after removed from the redirect-port-list action modifier. |
xos0075854 | If "ipmcforwarding iPv6" is enabled, then the installation of an ACL with "arp-sender-address" match condition fails. |
AVB | |
xos0075529 | Member port of a share group becomes AVB-incapable after tearing down the share group and re-creating it. |
Clocking | |
xos0075437 | Random values are added to GPTP packets. |
ELRP | |
xos0074513 | Ports disabled by ELRP due to a loop in the dynamic VLAN of NetLogin is not automatically re-enabled after timer expiry. |
EVPN | |
xos0071878 | With Auto-peering/EVPN configuration, upgrading to ExtremeXOS 30.x from
releases earlier than 30.1 produces error messages that are actually
informational:04/19/2018 08:58:47.57 <Erro:FDB.ArpError> ipv6_neighbour_conf_t_set# Error Ignoring user VR(vrid-3) IPv6 neighbor pending entries (1024) 04/19/2018 08:58:47.57 <Erro:FDB.ArpError> ipv6_neighbour_conf_t_set# Error vr-purple - Ignoring Ipv6 Neighbour entries (4096) 04/19/2018 08:58:47.48 <Erro:FDB.ArpError> arp_config_t_set# Error Ignoring user VR(vrid-3) ARP proxy entries (256) 04/19/2018 08:58:47.48 <Erro:FDB.ArpError> arp_config_t_set# Error Ignoring user VR(vrid-3) ARP pending entries (256) 04/19/2018 08:58:47.48 <Erro:FDB.ArpError> arp_config_t_set# Error vr-purple - Ignoring ARP entries (8192) These messages inform you that user-VR based ARP limits configured in previous versions of ExtremeXOS are ignored from 30.x onward, and that ARP limits are derived from global configured ARP limits. |
Extended Edge Switching | |
xos0073946 | On Extended Edge Switching controlling bridge (CB) switches, the show inline-power stats command takes longer than usual to display the output, and sometimes it returns "Timeout occurred while retrieving information from hardware." messages. |
xos0075689 | Switch becomes unresponsive for 5–15 minutes when UPM executes command in orchestration mode on both MLAG controlling bridges. |
MAC Security (MACsec) | |
xos0075817 | Incorrect error message appears when an ASCII string without 0x prefix is configured as the CAK. |
xos0075837 | If you use an .xsf script file to apply MACsec configuration and the commands to configure the optional MACsec parameters (include-sci, mka actor-priority, etc.) are listed before the command to enable MACsec, these optional MACsec parameters are not applied unless you run the initialization command. Standard configuration files (.cfg) are not affected by this issue. |
xos0075691 |
When MACsec is enabled on the same port that the MACsec Key Agreement (MKA) protocol will run on, if the local port is elected Key Server (KS), and the MACsec peer does not install and use a freshly distributed Secure Association Key (SAK) prior to its next MKPDU transmission, then the connection might never reach the secure state causing all traffic to be blocked. This issue occurs when inter-operating with third-party MACsec devices, and between ExtremeXOS devices when reconfiguring the cipher suite on multiple ExtremeXOS ports (for example, cipher suite from GCM-AES-128 to GCM-AES-256). |
Mirroring | |
xos0075204 | Mirroring a port to a remote IP address is not working on ExtremeSwitching X440-G2 series switches. Port+VLAN mirroring is not affected. |
MLAG | |
xos0074601 | Ping is not working on MLAG port of a mixed stack of Summit X460-G2 and ExtremeSwitching X620 series switches if Summit X460-G2 is the master. |
xos0075872 | Traffic loss occurs for more than 20 seconds when controlling bridge is rebooted or when you disable/enable ISC cascade port. |
xos0075939 | Enabling MLAG on a port in NP state causes traffic issues. |
MPLS | |
xos0074611 | Label mismatch issues between LDP routers after enabling LDP loop detection. |
xos0074924 | VPLS: VP leak occurs when switching pseudowire path from RSVP to LDP and vice versa. |
xos0075683 | VC label TTL has not been set correctly in VPLS. |
Network Login | |
xos0074606 | NetLogin users are authenticated to random destinations when destination VLAN attributes from the RADIUS server are not received. |
Policy | |
xos0066643 | NetLogin session is not cleared in session timeout when session timeout is received from RADIUS attribute. |
xos0074910 | Captive portal stops working when more clients try to access the captive portal page. |
xos0075057 | Traffic drop occurs when receiving LLDP packets on the ONEPolicy admin profile configured port. |
xos0075544 | Policy process ends unexpectedly at random time, when client in the network tries to access captive portal page. |
Security | |
xos0072784 |
Policy does not currently apply NSI in hardware for static and/or dynamic admin-profile configurations. Netlogin does not currently allow a port to be enabled if VXLAN is configured on the port. Note: For VXLAN, errors still occur for ports where policy is not active on that
port, when policy is globally enabled.
|
SNMP | |
xos0074806 | SNMP walk fails when trap receiver is configured using SNMP community strings starting with “v,w,x,y,z". |
Stacking | |
xos0074952 | Stack remains in listening state if both native and alternate ports are configured without inserted native port. |
STP | |
xos0074481 | All participating VLANs are removed from STP after deleting one port + VLAN from the STP domain. |
xos0076081 | Backup root needs to be triggered for root expiry. |