The following issues were resolved in ExtremeXOS 30.6. ExtremeXOS 30.6 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, and ExtremeXOS 30.5. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0076267 | Running the command run script clone.py slot all fails when the inactive partition has an ExtremeXOS 30.3 image on the master slot, and all other standby/backup slots have ExtremeXOS 30.4 on both partitions. |
xos0077550 | If default route is present, slow-path forwarding of multicast traffic does not occur correctly. |
xos0077732 | After a reboot simultaneous running of the show system command on 8 Telnet/SSH sessions results in cli master crash. |
xos0077793 | PIM routers should accept include-mode registers as per RFC compliance. |
xos0077898 | Software upgrade from ExtremeXOS 16.2 to 30.3, or later, fails during installation. |
xos0078029 | ExtremeXOS supports timezone GMT offset configuration from -720 to +720 minutes. This range needs to be extended to +840 minutes to support the time zone configuration of certain islands, such as Chatham (New Zealand), Kiribati island, etc. |
xos0077893 | After an IGMP receiver flaps twice, multicast streams are not forwarded to receivers by PIM-SSM. |
ExtremeSwitching X435 Series Switches | |
xos0076886 | On ExtremeSwitching X435, egress ACLs are not supported. |
ExtremeSwitching X440-G2 Series Switches | |
xos0077537 | On ExtremeSwitching X440G2-12p switches, 10G ports do not come up after a reboot. |
xos0077718 | On ExtremeSwitching X440-G2 series switches with auto-discovery enabled, 10G ports 25/26 go down after reboot if ports 27/28 have optics attached or if stacking support is enabled. |
xos0077772 | On ExtremeSwitching X440-G2 series switches using 1G optics on 10G ports, ports do not come up after rebooting. |
ExtremeSwitching X465 Series Switches | |
xos0077616 | When connecting a new node to a stack using automatic stacking, FPGA and CPLD is not updated on the new node. |
xos0077617 | When adding or replacing a node running the in a stack using automatic stacking, and the new node has the same software version as the master, but on the opposite partition, subsequent image downloads fail. |
ExtremeSwitching X870 Series Switches | |
xos0077775 | On ExtremeSwitching X870 series switches, Extreme-certified optics are detected as "unknown". |
ExtremeSwitching X460-G2 Series Switches | |
xos0078058 | On ExtremeSwitching X460-G2 VIM-2Q 40G ports, during power-up, or when inserting or removing transceivers, if stacking auto-discovery is enabled, multiple link flaps might occur. |
OSPFv3 | |
xos0077574 | OSPFv3 routes hold for spf-hold-time even when interface is taken down. |
Security | |
xos0075337 | With ONEPolicy and multiple authentication (MAC and Dot1x), session timeout and idle timeout are not applied to the Dot1x user when authenticated for the first time. |
xos0076261 | With NetLogin authentication mode optional configured, the first packet used for for authentication is not forwarded/flooded to other ports in the VLAN. |
xos0076294 | Memory leak occurs in thttpd process while accessing network web login page, causing a switch reboot. |
SNMP | |
xos0077494 | SNMP process ends unexpectedly with signal 6 after running the switch for 497 days. |
xos0078024 | On ExtremeSwitching X465, X690, X695, X590, and X870 series switches, Node Alias does not update the TLL of an existing MAC-IP entry with new DHCP. |
STP | |
xos0077434 | STP module default configuration does not appear in the output of the command show configuration stp detail. |
SummitStack | |
xos0075986 | Kernel error occurs when deleting a port from VRRP VLANs. |
VLANs | |
xos0076140 | IPv6 ping fails over PSTag. |