The following issues were resolved in ExtremeXOS 30.7.1-Patch1-54. ExtremeXOS 30.7.1-Patch1-54 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, and ExtremeXOS 30.7. For information about those fixes, see the release notes for the specific release.
Defect | Description |
---|---|
General | |
EXOS-27157 | HAL process ends unexpectedly on master node of SummitStack if stacking-related show commands are run when some other stacking slot is being unconfigured. |
EXOS-26783 | The command disable stpd s0 appears twice in the configuration if STP is disabled and if the default ST[D mode of s0 domain is changed. |
EXOS-27088 | SSH does not work with weaker public key-algorithm ssh-dss. |
EXOS-27541 | The process exsshd might end unexpectedly when closing an SSH connection. |
EXOS-27202 | ExtremeXOS adds a prefix of csr- to the common name in the Certificate Sign Request (CSR). |
EXOS-27226 | During VPLS fallback scenario, convergence happens within a second, which causes communication loss between CE devices. |
EXOS-27341 | If a non-tenant VMAN is added to the same port as CEP, then you are not able to ping the tenant VLAN IP on a VTEP. |
EXOS-27285 | Default-originate routes stop being transmitted over BGP/OSPF when BGP redistribute cost is high. |
EXOS-26378 | FDB is not learned on network VLANS when L2VPN sharing is not enabled on PE switches. |
EXOS-27152 | When there are flaps on MPLS cloud, VPLS FDB is leaked on network VLAN. |
EXOS-27068 | After a reboot, switch fails to load VLAN configuration on a port with remote mirroring configured. |
EXOS-27044 | Invalid entity warnings appear in log after ExtremeCloud request. |
EXOS-27427 | JSON request for a configuration change or save (admin privilege) fails for RADIUS-authenticated users. |
EXOS-26430 | Fabric Attach uplink is not added/removed in static/dynamic VLAN based on NSI status. |
EXOS-27390 | Installation of ACL rule entries containing multiple conditions of the same match type should be blocked. |
EXOS-27041 | TTL match condition is not updated during ACL smart refresh. |
EXOS-27258 | The show configuration difference command output incorrectly shows differences when the booted and the running configuration are identical. |
EXOS-27268 | On Extended Edge Switching topologies, pibAsicUpdOneDot1brPortEgressReplication' error messages appear when upgrading to ExtremeXOS 30.7. |
EXOS-27126 | VPEX process ends unexpectedly after unconfiguring and reconfiguring the extended slot (V300). |
EXOS-27169 | If switch is configured with slot:port notation, cable diagnostic script returns errors. |
EXOS-27011 | The process cliMaster ends unexpectedly when any show command is run with grep option and log target session is enabled. |
EXOS-27098 | In the output of the show stpd command, the operational edge status is not set to "true" for ports linked up at non-default speeds, such as 100M or 10M. |
EXOS-27006 | Nettools process ends unexpectedly when receiving DHCP packets with invalid DNS (0.0.0.0). |
EXOS-27085 | Inter-VLAN loops are not detected by ELRP on NetLogin VLANs when the port is set to MAC-based VLAN. |
EXOS-27270 | HAL process ends unexpectedly when ExtremeXOS retries detecting unsupported or third-party optics. |
EXOS-26734 | With loop present, FDB process ends unexpectedly after enabling ELRP hardware-assist feature. |
SummitStack | |
EXOS-26963 | Stacks do not come up successfully with default license if ExtremeSwitching X870/X695 series switches are mixed with other platform switches having master-capability set to on. |
EXOS-27386 | On SummitStacks, STP memory leak occurs on backup node for each MLAG port flap on peer switch. |
ExtremeSwitching X435 Series Switches | |
EXOS-27082 | ExtremeSwitching X435-8p switches remain in boot loop due to FDB process ending unexpectedly when upgrading to ExtremeXOS 30.7.1.1. |