The following issues were resolved in ExtremeXOS 31.2. ExtremeXOS 31.2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, ExtremeXOS 30.7, and ExtremeXOS 31.1. For information about those fixes, see the release notes for the specific release.
Defect Number | Description |
---|---|
General | |
EXOS-24249 | show netlogin session shows the wrong entry for unauthenticated user in non-policy mode. |
EXOS-27257 | The show configuration difference command output incorrectly shows differences when the booted and the running configuration are identical. |
EXOS-27510 | After running port statistics-related commands, the CLI stops responding. |
EXOS-27654 | Authentication for local user fails for SSH connection, including unreachable radius server. |
EXOS-27693 | On upgrade to EXOS 22.7 and later releases, processes like THTTPD are stuck in the load configuration state if there is a large amount of VLAN configuration. |
EXOS-27746 | CLI process consumes more CPU when the enable debug-mode command is executed and the session times out. |
EXOS-27764 | EXSH process crashes with signal 6 when issuing a double TAB after alias name. |
EXOS-27795 | A short loop is observed in the sharing link when performing a node failover in the stack. |
EXOS-27799 | When loopback mode is enabled on the bootp client VLAN, the response is incorrectly sent to the default route. |
EXOS-27829 | RTMGR process crashes with signal 6 due to stale BGP entries. |
EXOS-28013 | LLDP advertise port displays "string" instead of "port" description string. |
EXOS-28193 | With a newly formed stack, LLDP is disabled for all the slot ports except the primary slot. |
ExtremeSwitching X670-G2 Series Switches | |
EXOS-27602 | Non-partitioned 40G ports in backup/standby slots incorrectly display as Ready instead of "NP" for not present. |
ExtremeSwitching X440 Series Switches | |
EXOS-27701 | On "Admin enable" operation, STP PDU is not sent out immediately if the edge port is configured with edge safeguard and BPDU restrict is enabled. |
ExtremeSwitching X440-G2 Series Switches | |
EXOS-26563 | ExtremeSwitching X440-G2 fan profile causing hyperventilation. |
EXOS-27398 | Operational Edge port status is incorrectly set to FALSE for 100/10 Mbps port. |
ExtremeSwitching X460-G2 Series Switches | |
EXOS-27868 | The aging value of FDB entries are incorrectly displayed as 0. |
EXOS-28075 | Two-Way Active Measurement Protocol (TWAMP) feature does not work as expected in EXOS 30.x. |
ExtremeSwitching X465 Series Switches | |
EXOS-27573 | Re-convergence time on an ExtremeSwitching X465 series stack has increased from ~50 msec in ExtremeXOS 30.7 to greater than 3 seconds in ExtremeXOS 31.1. |
ExtremeSwitching 5520 Series Switches | |
EXOS-27495 | Cisco 7821 IP phones might not be able to auto-negotiate to 100Mbps when connected to 1G copper ports. Instead, the connection occurs at 10Mbps. |
EXOS-27571 |
The ExtremeSwitching 5520 series switches PoE power budget limits have been reduced for the following PSU configurations: 5520-24W: 2 × 1100W PSUs—PoE budget is reduced from 1,800W to 1,781W 5520-48W: 2 × 2000W PSUs (200–240VAC)—PoE budget is reduced from 3,600W to 3,568W 5520-48W: 2 × 1100W PSUs—PoE budget is reduced from 1,800W to 1,770W 5520-12MW-36W: 2 × 2000W PSUs (200–240VAC)—PoE budget is reduced from 3,600W to 3,549W 5520-12MW-36W: 2 × 1100W PSUs—PoE budget is reduced from 1,800W to 1,751W ExtremeXOS 31.1 enforces the previous limits. The new limits are implemented in ExtremeXOS 31.2. |
EXOS-27609 | Process OSPFv3 fails after running restart ports all with an OSPFv3 virtual-link configuration on ExtremeSwitching 5520 series. |
EXOS-27728 |
Standalone ExtremeSwitching 5520 series switches should support 32 ports per load-sharing group. However, currently you cannot create load-sharing groups with more than 8 ports. Note: This value is the maximum number of ports allowed in the aggregator. When you create an LACP LAG or when adding ports to it, twice the supported value is permitted in the load-sharing group to allow for standby ports. |
EXOS-27860 | After switching NOS from EXOS to VOSS and back to EXOS, /scratch/nos has an unclean .xos image, leading to a "no space" error during image download. |
Extended Edge Switching | |
EXOS-26582 | Multicast traffic loss observed in enterprise bed VPEX ring + MLAG setup. |
EXOS-27637 | When configuring LAG on extended ports, a short loop is detected in a switch. |
EXOS-27914 | VPEX topology is stuck in Severed State after rebooting the V300 Virtual Port Extender node. |
EXOS-27917 | VPEX - default Policy consumes excess ACL hardware resources. |
EXOS-28076 | The nodealias process crashes with signal 11, leading to a switch reboot. |
Fabric Attach | |
EXOS-26121 | Dynamic FAMgmt VLAN is not cleared on PROXY when it transitions to CLIENT. |
EXOS-27431 | fabric attach management-vlan config is not cleared when FA mode changes from server to client. |
EXOS-27902 | When the number of FA elements crosses 20, the show fabric attach elements output is empty. |
SummitStack | |
EXOS-26668 | HAL process crashes when the host moves from network VLAN to subscriber VLAN. |
EXOS-26946 | An error message appears on both stack primary and backup nodes when a virtual network with VNID <#> is not found on the backup slot. This occurs when the client is authenticated and dynamic VNI is created on the stack node. However, traffic flows in both the directions without issue. |
EXOS-27303 | Backup node traffic is incorrectly learned on normal VLAN instead of VXLAN, causing traffic to get dropped on both ingress and egress direction. |
EXOS-27767 | HAL process ends unexpectedly on the backup node when the standby node comes back online after a reboot. |
Extreme Loop Recovery Protocol (ELRP) | |
EXOS-26746 | Inter-VLAN loop is not detected by ELRP on Netlogin VLAN when port is set to mac-based VLAN. |
EXOS-27632 | ELRP process ends unexpectedly after receiving an invalid packet with ELRP destination MAC address. |
STP | |
EXOS-27701 | When running the admin enable command, STP PDU is not sent out immediately if the edge port is configured with edge safeguard and BPDU restrict is enabled. |
VLAN | |
EXOS-27553 | Enabling netlogin on a port in the default VLAN does not move that port to the netlogin configured VLAN. |
EXOS-27576 | After a reboot, the switch fails to load VLAN configuration on a port with remote mirroring configured. |