Defect Number Description
General
CFD-9602 When a new dot1x client is authenticated on a port, the accounting stop is not sent for the old dot1x client and the accounting start is not sent for the new client. 
CFD-9616 Router-discovery configurations were missing after disabling/enabling VRRP instance.
CFD-9636 Static fdb VxLAN entry is programmed with 30 minutes delay after switch restarts, even when the VxLAN tunnel is UP.
CFD-9690 Error message is not generated when there are failures in installing ACL rules enforced from XIQ-SE though policy profile.
CFD-9694 ACL Signal 11 crash is observed when ACL is added from a script and the process crash causes a switch reboot.
CFD-9882 IDmgr critical log was seen when flapping the port with 1000+ dynamically created VLANs.
CFD-9919 Switch restarts because of a kernel crash.
CFD-9973 CLI session hangs when applying PBR policy whose file name is 32 characters, and when file name exceeds 32 characters policy check fails.
CFD-9996 On a stack, the backup and Standby Slot port configuration information is not returned when ExtremePortConfigTable is polled.
CFD-10072 VRRP hello's were dropped when its forwarded over ISC.
CFD-10120 SNMP traps were not getting generated when there is an IP Security ARP violation despite the corresponding configuration being present in the switch.
CFD-10255 Netlogin Client not learnt on port after STP convergence.
CFD-10300 FDB process crash was seen when polling fdb.ipNetToPhysicalEnt MIB.
CFD-10311 A local file will be used to restore DHCP-binding information if the remote server is unreachable.
CFD-10352 Policy (.pol) files imported via the "Download URL" command are not synced to the backup node on summit stack switches.
CFD-10416 rtmgr process crash was seen when enabling BFD on ipv6 prefix.
CFD-10466 SSH-RSA public key authentication method fails with error "no mutual signature algorithm" in SSH client.
CFD-10474 unconfigure switch all does not remove the configure system port notation setting
CFD-10475 Netlogin allowed-uses does not work as expected.
CFD-10494 mcmgr process crash was seen when fast-leave is enabled and receiving leave message.
CFD-10575 Error was seen when executing config account admin encrypted <pwd> command.
CFD-10583 .cfg file transferred to swtich not available for use until reboot or copied to another file.
CFD-10613 Resource leak was seen in the hardware when deleting all ports in a VLAN.
CFD-10614 SSH key becomes invalid sometimes during the reboot of the switch.
CFD-10688 Accounts created using encrypted password, the expiry date was not shown.
CFD-10754 XML-Notification was not sent with the configured source IP.
CFD-10781 ACL process crash was seen when applying a policy with match condition OSPF on the VLAN.
CFD-10816 User list in Chalet becomes empty/blank when the number of users is one.
CFD-10918 L2VPN service name with 32 characters can hang CLI session.
CFD-10946 Switch brings up the ports when diagnostics tests are running.
CFD-10968 MVRP VLAN is not check-pointed to the MLAG peer when the corresponding remote MLAG port is inactive.
CFD-11018 Polling the  dot1dTpFdbTable information through SNMP returns the value with an additional octet. 
CFD-11160 Memory leak is observed in VLAN process when there are port flaps.
EXOS-31480 After a stack restart, a 25 Gbps port inserted with a 10 Gbps 10301 optic transceiver goes down in Backup and Standby nodes.
EXOS-31609 Loop is observed in MLAG topology when MACSEC is enabled on MLAG ports.
EXOS-32500 DM error was seen when sending IPARP packets more than configured entries.
EXOS-32696 File uploaded from Chalet are not synced with the backup slot
EXOS-33307 Dot1x clients are randomly admin-reset as soon as they are authenticated.
EXOS-33850 Stack was rebooted after executing disable/enable mirror when stack port was added as loopback port in mirroring.
EXOS-35861 "Supported Limits" will need to change to TBD values for 7520/7720 IPv4 and IPv6 routes in hardware. (Perhaps 256K IPv4 and 128K IPv6 64-bit, depends on test results).
X440-G2 Series Switches
CFD-10407 MACsec ports are not active after switch reboot.
X435 Series Switches
EXOS-33298 expy process crashes with signal 6 observed sometimes.
Summit Stack
CFD-9627 Image was not synced to standby node in the stack when copying the image by using SFTP put in the server.
CFD-9840 MLT session was not up after enable/disable jumbo-frames when EXOS stack is enabled with VPEX.
CFD-10056 Error message was seen when creating LAG with Master and backup node VIM ports.
CFD-10508 ARP probe packets are sent from the backup slot in a stack with its own physical MAC-address as the source-address. 
CFD-10647 Switch started to respond for ARP requests with source MAC address as all zeroes or VRRP MAC.
VPEX
CFD-9531 The show tech-support gets stuck at "show vpex" command with specific VPEX configuration. 
CFD-9884 HAL process crash was seen when sending multicast packets to more than 33 BPEs and when disabling/enabling the ports in a BPE.