Resolved Issues in ExtremeXOS 32.7.1

The following issues were resolved in EXOS 32.7.1. Version 32.7.1 includes all fixes up to and including versions 31.6, 31.7, 32.1, 32.2, 32.3, 32.4, 32.5, and 32.6.x.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 32.7.1
Defect Number Description
General
CFD-9602 When a new dot1x client is authenticated on a port, the accounting stop is not sent for the old dot1x client and the accounting start is not sent for the new client. 
CFD-9616 Router-discovery configurations were missing after disabling/enabling VRRP instance.
CFD-9636 Static fdb VxLAN entry is programmed with 30 minutes delay after switch restarts, even when the VxLAN tunnel is UP.
CFD-9690 Error message is not generated when there are failures in installing ACL rules enforced from XIQ-SE though policy profile.
CFD-9694 ACL Signal 11 crash is observed when ACL is added from a script and the process crash causes a switch reboot.
CFD-9882 IDmgr critical log was seen when flapping the port with 1000+ dynamically created VLANs.
CFD-9919 Switch restarts because of a kernel crash.
CFD-9973 CLI session hangs when applying PBR policy whose file name is 32 characters, and when file name exceeds 32 characters policy check fails.
CFD-9996 On a stack, the backup and Standby Slot port configuration information is not returned when ExtremePortConfigTable is polled.
CFD-10072 VRRP hello's were dropped when its forwarded over ISC.
CFD-10120 SNMP traps were not getting generated when there is an IP Security ARP violation despite the corresponding configuration being present in the switch.
CFD-10255 Netlogin Client not learnt on port after STP convergence.
CFD-10300 FDB process crash was seen when polling fdb.ipNetToPhysicalEnt MIB.
CFD-10311 A local file will be used to restore DHCP-binding information if the remote server is unreachable.
CFD-10352 Policy (.pol) files imported via the "Download URL" command are not synced to the backup node on summit stack switches.
CFD-10416 rtmgr process crash was seen when enabling BFD on ipv6 prefix.
CFD-10466 SSH-RSA public key authentication method fails with error "no mutual signature algorithm" in SSH client.
CFD-10474 unconfigure switch all does not remove the configure system port notation setting
CFD-10475 Netlogin allowed-uses does not work as expected.
CFD-10494 mcmgr process crash was seen when fast-leave is enabled and receiving leave message.
CFD-10575 Error was seen when executing config account admin encrypted <pwd> command.
CFD-10583 .cfg file transferred to swtich not available for use until reboot or copied to another file.
CFD-10613 Resource leak was seen in the hardware when deleting all ports in a VLAN.
CFD-10614 SSH key becomes invalid sometimes during the reboot of the switch.
CFD-10688 Accounts created using encrypted password, the expiry date was not shown.
CFD-10754 XML-Notification was not sent with the configured source IP.
CFD-10781 ACL process crash was seen when applying a policy with match condition OSPF on the VLAN.
CFD-10816 User list in Chalet becomes empty/blank when the number of users is one.
CFD-10918 L2VPN service name with 32 characters can hang CLI session.
CFD-10946 Switch brings up the ports when diagnostics tests are running.
CFD-10968 MVRP VLAN is not check-pointed to the MLAG peer when the corresponding remote MLAG port is inactive.
CFD-11018 Polling the  dot1dTpFdbTable information through SNMP returns the value with an additional octet. 
CFD-11160 Memory leak is observed in VLAN process when there are port flaps.
EXOS-31480 After a stack restart, a 25 Gbps port inserted with a 10 Gbps 10301 optic transceiver goes down in Backup and Standby nodes.
EXOS-31609 Loop is observed in MLAG topology when MACSEC is enabled on MLAG ports.
EXOS-32500 DM error was seen when sending IPARP packets more than configured entries.
EXOS-32696 File uploaded from Chalet are not synced with the backup slot
EXOS-33307 Dot1x clients are randomly admin-reset as soon as they are authenticated.
EXOS-33850 Stack was rebooted after executing disable/enable mirror when stack port was added as loopback port in mirroring.
EXOS-35861 "Supported Limits" will need to change to TBD values for 7520/7720 IPv4 and IPv6 routes in hardware. (Perhaps 256K IPv4 and 128K IPv6 64-bit, depends on test results).
X440G2
CFD-10407 MACsec ports are not active after switch reboot.
435
EXOS-33298 expy process crashes with signal 6 observed sometimes.
Summit Stack
CFD-9627 Image was not synced to standby node in the stack when copying the image by using SFTP put in the server.
CFD-9840 MLT session was not up after enable/disable jumbo-frames when EXOS stack is enabled with VPEX.
CFD-10056 Error message was seen when creating LAG with Master and backup node VIM ports.
CFD-10508 ARP probe packets are sent from the backup slot in a stack with its own physical MAC-address as the source-address. 
CFD-10647 Switch started to respond for ARP requests with source MAC address as all zeroes or VRRP MAC.
VPEX
CFD-9531 The show tech-support gets stuck at "show vpex" command with specific VPEX configuration. 
CFD-9884 HAL process crash was seen when sending multicast packets to more than 33 BPEs and when disabling/enabling the ports in a BPE.