Resolved Issues in VOSS 8.5

VOSS 8.5 incorporates all fixes from prior releases, up to and including VOSS 8.4.3:

Issue number

Description

VOSS-9917

The log message INFO Switch Externally Rebooted with CoreDump does not consistently appear on the console port before reboot when you select the softResetCoreDump option from EDM.

VOSS-19141

VOSS 8.1.7.0: Switch is not forwarding traffic and L2 pings via established FE tunnel.

VOSS-19721

VOSS: Egress Q7 overrun impacts entire Fabric when replacing a unit in the stack.

VOSS-20634

VSP 7400 Series 8.2.7.0: CPLD version to be displayed in CLI command show sys-info cpld output.

VOSS-21204

Incorrect Operate speed displays for some ports in Device Physical View in EDM for Segmented Management Interface.

VOSS-21241

For VSP 4450 Series, only one EAP/NEAP MAC is learned on a port configured with MAC FDB limit.

VOSS-21314

EDM disconnects after exceeding inactivity-timeout even if there is activity.

VOSS-21315

When the 5520 Series boots with factory default configuration (or with the default auto negotiation configuration) and the port is admin enabled, the 5520-VIM-4YE versatile interface module (VIM) might not operate when the SFP28 is inserted in the port for the first time.

VOSS-21630

VSP 8404: Specific inter vrf traffic outage after upgrading from 6.1.1.0 to 7.1.X and then 8.1.9.

VOSS-21815

VSP 7400 Series: DVR Controller inconsistency in alternative routes (direct interfaces are not always learned).

VOSS-22033

The time set by clock command does not properly change the time.

VOSS-22335

Considerable drift between BFD In and out packets in a scaled setup.

VOSS-22364

VSP 7200 Series: Switch is not reachable via SSH when is the VRRP Master.

VOSS-22461

In a scaled Multi-area SPB topology with a large number of multicast streams, a loss of multicast traffic can occur when restarting IS-IS on a designated boundary node.

VOSS-22468

The following DBSYNC warning message displays in a Multi-area SPB topology with a large number of distributed DvR host routes when DvR controllers are bounced in different areas:

1 2021-09-03T07:33:50.780Z VSP7432-2 CP1 - 0x00390602 - 00000000 GlobalRouter DBSYNC WARNING TLV not found inlocal DB Sync data base, deletion failed! TLV: Type: BB_HOSTROUTE | Len: 37 | Rsvd: 0x00 | L3ISID: 0 | L2ISID: 30 |IPv4: 10.30.44.20/32 | BDA MAC: 12:00:02:ff:ff:f0 | CDA MAC: 00:00:52:44:da:f1 | DomainId: 9999 | dvrCtrlSysId: 12:00:02:ff:ff:f0

VOSS-22537

5520 Series: SSH session hangs when switch tries to send packet with TCP MSS 1460 bytes over logical interface.

VOSS-22560

Sys software commit-time does not change the confirm-time.

VOSS-22566

5520 Series: Traffic arrived on fabric extend over ELAN on Sec BEB (vist node) does not reach the primary BEB (vist peer) due to being not encapsulated with spb header.

VOSS-22631

VSP 4900 Series and 5520 Series: SNMP Walk 1.3.6.1.4.1.2272.1.4.8 timeout for about 60 seconds.

VOSS-22635

Unexpected reboot of a VSP 4450GSX-PWR+.

VOSS-22678

Log Error 0x000e460b: IP Address format in Reverse Canonical Order.

VOSS-22682

Traffic flows between Private VLAN isolated ports.

VOSS-22691

The result of show pluggable-optical-modules detail have lack of information.

VOSS-22743

5520 Series: POE: default 802.3at+legacy pd detection mode is not being applied on bootup.

VOSS-22745

VOSS 8.4.1.1: lacp trace 59 not showing critical diagnostics info including system id, lacp key as we could see on ERS 8600 or VSP 8600.

VOSS-22750

VOSS: E-Tree allows traffic between isolated ports machines.

VOSS-22758

Dynamic Nickname not received by VSP 4900 Series without a reboot.

VOSS-22780

TZ: zoneinfo files need to be updated to reflect changes in daylight savings time around the world.

VOSS-22867

SPB nickname is not assigned when ISIS authentication is used.

VOSS-22890

VSP 7400 Series 8.3.1.0: The feature "fragment-before-encrypt" can be added incorrectly without an error message returned.

VOSS-22894

VOSS: Unable to assign IP address to VLAN 1 via EDM.

VOSS-22898

Tagged DHCP packets are leaking on routed DHCP relay VLANs.

VOSS-22921

VSP 7400 Series 8.2.7: Connecting to external google time servers (iqagent disabled)

VOSS-22922

After XIQ integration, unable to login into VOSS switch after reboot using configured user credentials.

VOSS-22947

VOSS CLI commands introduced to provision FIGW needs helper file and documentation.

VOSS-22986

OCSP checks should not be performed when AIA OCSP URL is missing in the certificate (nonESM).

VOSS-23003

VOSS 8.4.2: Default auto-sense wait time (35 seconds) makes EAPoL authentication of Windows clients impossible.

VOSS-23014

VSP 7200 Series rollback with coredump while upgrading from 7.1.10 to 8.1.10

VOSS-23016

Log "MLT WARNING smltTick: The ISIS peer adjacency failed to come up" appeared even when the adjacency was UP.

VOSS-23071

VSP 4900 Series, VSP 7400 Series, 5520 Series, and 5420 Series 8.4.2.x: CPU vs MAC sensor OID read change.

VOSS-23089

VSP 7254XSQ 8.2.8.0: BFD packets form Palo Alto FW getting copied to CPU with qos=6 going into VRRP queue when traversing L2VSN.

VOSS-23090

PSU 1 details shows blank on U5420F on VOSS Code.

VOSS-23140

VOSS 8.4: RADIUS reachability password gets appended to the username if username exceeds 15 characters.

VOSS-23144

VSP 4850 Series/VSP 4450 Series have "show int gig loop-detected" cmd even though loop-detect cmd does not exist.

VOSS-23173

VOSS: Statically configured LLDP MED Voice parameters not sending to Alcatel Lucent phone.

VOSS-23244

Connectivity to the VRRP IP on other switches gets lost after removing VLAN IP address or VRRP config one switch.

VOSS-23371

VSP 7400 Series: Tx and Rx Actual Value is not visible on EDM.

VOSS-24743

Switch core-dumps when installing offline certificate.