Resolved Issues in Switch Engine 32.5

The following issues were resolved in Switch Engine 32.5. Version 32.5 includes all fixes up to and including versions 31.6, 31.7, 32.1, 32.2, 32.3, and 32.4.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 32.5
Defect Number Description
General
CFD-9524 LACP port is not added to aggregator after flap in MLAG.
EXOS-32890 The default FEC configuration is missing for some ports.
EXOS-32924 The stacking link status and stacking link speeds are not correct when polled using OIDs 1.3.6.1.2.1.2.2.1 and 1.3.6.1.2.1.31.1.1.
EXOS-33022 IP Address is returned in reverse order when IP-MIB is polled.
EXOS-33063 There is a delay in displaying the output of the show ports forward-error-correction command for not-present ports.
EXOS-33197 HAL process crash occurs after flapping BFD session.
EXOS-33290 Local authentication failover doesn't work when using Chalet.
EXOS-33314 STP fails to block loop when using Policy admin profile.
EXOS-33516 The SNMP trap source IP address configured using SNMP set requests is not saved to the stack backup and is lost if the stack's primary node reboots.
EXOS-33619 MLAG can be enabled on a cascade port in a VPEX+Stacking environment.
EXOS-33633 Need support for RADIUS port bounce VSA.
EXOS-33657 Error log needs to be displayed when OnePolicy ACL cannot be installed in the hardware.
EXOS-33676 End client is accessible even though it fails netlogin authentication.
EXOS-33930 10203 FORMERICAOE optics flapping after changing link speed to 10G.
EXOS-33931 An error occurs when enabling MACsec on the primary node of a stack.
EXOS-33934 The following error message displays in the switch after restart:<Erro:cm.sys.LoadApplCfgObjFail> Slot-1: "exsshd" application failed to load "exsshdPrivKey" configuration object: Error reading SSH key.