The Redundant Management Interface feature provides fault tolerance for the management path.
The following procedure configures redundant management on port 0/15 with a Mellanox Adapter.
The following example displays the Redundant Management Interface configuration on a SLX 9250 with 4x10G.
SLX# show running-config hardware connector 0/15 breakout mode
hardware
connector 0/15
breakout mode 4x10g
!
SLX# show running-config interface Ethernet 0/15:1
interface Ethernet 0/15:1
redundant-management enable
no shutdown
!
SLX# show interface ethernet 0/15:1
Ethernet 0/15:1 is up, line protocol is up (connected)
Redundant management mode is enabled
Hardware is Ethernet, address is f46e.95a1.f826
Current address is f46e.95a1.f826
Fixed Copper RJ45 Media Present
Interface index (ifindex) is 201589248 (0xc040200)
MTU 9216 bytes
IP MTU 1500 bytes
Maximum Speed : 10G
LineSpeed Actual : 10000 Mbit
LineSpeed Configured : Auto, Duplex: Full
Priority Tag disable
Forward LACP PDU: Disable
Route Only: Disabled
Tag-type: 0x8100
Last clearing of show interface counters: 02:45:29
Queueing strategy: fifo
FEC Mode - Disabled
Receive Statistics:
81295 packets, 6130007 bytes
Unicasts: 1212, Multicasts: 71717, Broadcasts: 8363
64-byte pkts: 62703, Over 64-byte pkts: 17088, Over 127-byte pkts: 545
Over 255-byte pkts: 606, Over 511-byte pkts: 117, Over 1023-byte pkts: 233
Over 1518-byte pkts(Jumbo): 0
Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0
Errors: 0, Discards: 0
Transmit Statistics:
742 packets, 66702 bytes
Unicasts: 426, Multicasts: 316, Broadcasts: 0
Underruns: 0
Errors: 0, Discards: 0
Rate info:
Input 0.005267 Mbits/sec, 9 packets/sec, 0.00% of line-rate
Output 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Route-Only Packets Dropped: 0
Time since last interface status change: 00:00:44