Resolved Issues in ExtremeXOS 16.1.3-Patch1-7

The following issues were resolved in ExtremeXOS 16.1.3-Patch1-7. ExtremeXOS 16.1.3-Patch1-7 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, and ExtremeXOS 16.1.3. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) for ExtremeXOS 16.1.3-Patch1-7

CR Number Description
General
xos0056729 After being deleted from the switch, old configuration files are incorrectly visible in the help menu.
xos0057931 After rebooting the switch multiple times, following error log message appears:
<Erro:cm.loadErr> Failed to load configuration: timed out (after 150 seconds) while waiting for all applications to get ready to load configuration on OPERATIONAL ( eaps is still not ready yet).
xos0061597 After authenticating a NetLogin client, executing the command clear netlogin state port, and then checking that ID-mgmt has deleted the clients, log displays UnDscvrId EMS message, which does not indicate the identity user.
xos0062265 Some legacy commands are not recognized.
xos0062720 Unable to save configuration when ACL/CFM is configured on multiple VLANs.
xos0063332 Configuration changes to VPLS are not fully retrieved by SNMP walk, which returns values for only few VPLS index.
xos0063980 EDP process crash with signal 11 when receiving CDP packet with IPv6 address type.
xos0064009 MLAG+EAPS:Traffic forwarding stops after EAPS that include ISC link converges.
xos0064054 SNMPwalk on extremeAclStatsTable returns value with port instance instead of ifIndex.
xos0064055 Resiliency Enhancement for IPv4 and IPv6 Static Routes feature has been added.
xos0064151 Errors occur when removing DHCP configuration from VLANs when LAG ports are added to the VLANs.
xos0064223 Need to add an ACL match condition for matching next-hop addresses during the look-up cycle of a packet, so that actions can be taken based on the next-hop a packet is destined for.
xos0064278 In a SummitStack or BlackDiamond chassis, FDB is not programmed in hardware after three failovers and fallback.
xos0064043 Unable to use a configuration file that has been copied from an existing configuration file.
xos0064129 Policy refresh never completes with network-zone configuration.
xos0064215 The following log message appears when a subnet is reachable both using MPLS and non-MPLS:
<Warn:Kern.IPv4FIB.Warning> Slot-4: dest 0x0A420000 / 24 nexthop 0xAC11121E: Unable to add route to unit 1, rc Entry not found. Shadow problem
xos0064307 RADIUS accounting configuration is incorrect as shown by the command show conf aaa and is lost after upgrade.
xos0063838 Vulnerability to CVE-2016-0800 Cross-protocol attack on TLS using SSLv2 (DROWN).
xos0063554 The following vulnerability in OpenSSL exists that impacts ExtremeXOS (CVE-2015-3197): A malicious client can negotiate SSLv2 ciphers that have been disabled on the server and complete SSLv2 handshakes even if all SSLv2 ciphers have been disabled, provided that the SSLv2 protocol was not also disabled via SSL_OP_NO_SSLv2. This issue affects OpenSSL versions 1.0.2 and 1.0.1.
Summit X430 Series Switches
xos0064084 In Summit X430 series switches, the command show power details displays fan status as "empty".
Summit X440 Series Switches
xos0063627 ARP is not re-added to hardware after it is removed initially due to the table being full.
xos0064049 Need command provision to tune pre-emphasis settings for stacking port on Summit X440 series switches.
xos0064050 While running diagnostics on a Summit X440 10G model switch with revision 10 and diagnostics test version 6.0 or above, “Test loopback phy fiber" and "Test snake interface" fail.
Summit X460-G2 Series Switches
xos0063811 Summit X460-G2 series switches with ExtremeXOS 15.6 through 21.1, have the following limitations for SyncE input reference frequency:
  • Network clock does not lock with input SyncE source port 52 (both at 10G and 1G speed) on all 48-port models (X460-G2-48t, 48x and 48p).
    Workaround: For SyncE input at 10G, avoid port 52.
  • When the 10G ports operate at 1G speed, the network clock does not lock. Models with Ethernet BASE-T or Power over Ethernet (PoE) ports may lock on initial configuration, but do not lock after a save and reboot.
    Workaround: For SyncE input at 1G, use a 1G port, not a 10G port.
SummitStack
xos0061834 In SummitStacks, the command synchronize stacking slot slot no does not work from master node if the target slot is in failed state.
xos0061861 A per-port meter configured on a SummitStack may not be properly configured on the backup node following a reboot.
BlackDiamond X8 Switches
xos0062262 UDP profile configurations on VLANs do not take effect in BlackDiamond X8 series switches.
xos0063080 ACL rule with destination zone match condition does not take effect, since IP address gets installed in reverse order in hardware.
xos0063958 BDX8-40G12X-XL module goes into reboot cycle if any physical loop is configured or a network loop is present on the module.
xos0064010 The command show port buffer displays an incorrect port range for 100G I/O modules.
xos0064201 On BlackDiamond X8 chassis with BDXA-40G24X modules loaded in all I/O slots, some modules may occasionally time out while booting up.
xos0064444 Management module crashes continuously when there is a physical loop on the front panel ports of the I/O module.