The following issues were resolved in ExtremeXOS 16.1.4-Patch1-7. ExtremeXOS 16.1.4-Patch1-7 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3, and ExtremeXOS 16.1.4. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0066804 | Routes learned from OSPF are lost after multiple port flaps occur. |
xos0061317 | Switch reboots unexpectedly when enabling FIP snooping. |
xos0054972 | The output of the debug hal show congestion command displays the wrong CPU congestion counter values, which are much higher than the actual dropped packets. |
xos0059489 | ERPS process crashes with signal 11 when ERPS tries to send hello packet during reboot. |
xos0062664 | MIB compilation issues occur with ID-MGR MIB when using mgsoft. |
xos0062670 | ENTERASYS-UPN-TC-MIB needs to be included in Extreme MIB file. |
xos0063532 | IGMP report packets are not processed when received on VMAN CEP port. |
xos0063551 | SNMP polling on CFM segment frame-delay statistics returns incorrect values. |
xos0063959 | BGP routes become unfeasible when default routes are advertised through OSPF or BGP. |
xos0065150 | When LAG ports are added to VPLS, LACP flap occurs after rebooting the slots in the stack. |
xos0065159 | Openflow process ends unexpectedly with signal 11 when OpenFlow controller installs LLDP flow. |
xos0065210 | With account lockout feature configured, an appropriate log message is not generated when users are locked out after three unsuccessful login attempts. |
xos0065321 | With SSH session, source address information is not sent to TACACs accounting server. |
xos0065372 | MPLS error messages occur after disabling, and then enabling network VLANs. |
xos0065479 | A CLI option is needed to save the state of whether or not the following traps are enabled for cfgMgmtConfigChangeTrap and cfgMgmtSaveConfigTrap. |
xos0065490 | IGMP packets are forwarded over EAPS-blocked ports when PSTAG is configured on protected VLANs. |
xos0065525 | Need modifications in port ID TLV. Device ID TLV is sent in CDP messages. |
xos0065542 | Kernel crash occurs when rebooting the switch with a physical loop. |
xos0065552 | RADIUS-accounting request packet shows incorrect reason for client termination. |
xos0065615 | Local multicast traffic is not egressing using a newly added member port in a LAG. |
xos0065648 |
When a MAC address moves from a NetLogin-enabled port (mac-vlan mode) to a
non-NetLogin-enabled port, the VLAN_MAC table can become full resulting in the
following message:
<Warn:HAL.FDB.MacVlanAddFail> MAC-based VLAN entry 78:7E:61:A1:DC:DC vlan 2600 addition to port 22 failed, Table full |
xos0065805 | Constant flush happens in ERPS non-revertive mode when the port being blocked is non-RPL. |
xos0065830 | After port flaps, OSPF-learned routes are not present in kernel database. |
xos0065943 | SNMP walk for extremePortUtilizationTable returns integer value, but CLI output returns decimal value. |
xos0065972 | HAL process ends unexpectedly with signal 6 when rebooting stacks with virtual MAC configuration for ESRP. |
xos0065977 | Random Nettools process ends unexpectedly with Signal 5 when router discovery and DNS is enabled. |
xos0066060 | OpenFlow error message appears when rule is not getting installed in hardware and same flow is received immediately for another installation. |
xos0066140 | RSTP BPDU is not trasmitted even though STP state is in forwarding mode when loop-protect is enabled. |
xos0066156 | Switch reboots unexpectedly due to memory leak in dot1ag process. |
xos0066231 | With default NetLogin configuration, extremeNetloginuser login and logout traps are not sent. |
xos0066345 | XMLC process ends unexpectedly with signal 6 when sending XML notification to Ridgeline server. |
xos0066367 | Need to have a "clear" command to change ERPS ring state from "pending" to "idle" state. |
xos0066398 | COA disconnects are incorrectly logged as idle timeouts in EMS. |
xos0066476 | MPLS label TTL is not set properly for VPLS traffic in RSVP-TE. |
xos0066626 | NetLogin process ends unexpectedly with signal 11 when RADIUS accept packet contains MS-ipv4-remediation-servers attribute with an incorrect IP address. |
Summit X440 Series Switches | |
xos0064196 | Error log message "could not clear eee stats" appears after issuing clear counters command. |
SummitStack | |
xos0066008 | Random slots or whole stack reboots when one of the standby nodes in the stack is power cycled with sys-recovery-level configured as "shutdown". |
xos0066029 | In Summit X460-G2 stacks, LACP keeps flapping due to forwarding one LACP PDU to another group. |
xos0065387 | SNMP times out while when saving on an eight-node stack of Summit X440 series switches. |
BlackDiamond 8800 Series Switches | |
xos0065735 | BlackDiamond 8500-MSM24 modules are not supported beyond the ExtremeXOS 15.6 release, but installation of for unsupported ExtremeXOS releases is not blocked. |
xos0066143 | IGMP snooping per-VLAN mode causes additional slice utilization in G48Te2 modules. |