The following issues were resolved in version 33.7.1. Version 33.7.1 includes all fixes up to and including versions 31.6, 31.7, 32.1, 32.2, 32.3, 32.4, 32.5, 32.6.x, 32.7.x, 33.2.1, 33.3.1, 33.4.1, 33.5.x, and 33.6.x.
| Defect Number | Description |
|---|---|
| General | |
| EXOS-31609 | A loop occurs in a two-tier MLAG setup. |
| EXOS-33936 | The NOS API STP GET does not return all VLANs. |
| EXOS-33945 | The show port utilization output is not accurate in a digital-twin environment. |
| EXOS-33949 | The NOS API does not allow setting a priority value of 0 using POST or PATCH operations. |
| EXOS-33954 | NOS API GET on /configuration/accounts does not list Lawful Intercept user details when queried with elevated privilege. |
| EXOS-33956 | The NOS API PATCH operation incorrectly allows setting an account password to a null string. |
| EXOS-33958 | The NOS API PoE Power endpoint returns an incorrect value on non-PoE platforms. |
| EXOS-34002 | In a digital-twin environment, VR-Ctrl traffic leaks into the VR-Mgmt network. |
| EXOS-34006 | The disable snmp traps identity-management and enable snmp traps identity-management commands do not work intermittently. |
| EXOS-34020 | The 40G auto-negotiation enable configuration is not saved for a 100G non-partitionable port. |
| EXOS-34030 | An endian encoding error causes incorrect values in SNMP trap data. |
| EXOS-34084 | Creating a provider service tag VLAN with a tag that matches an IPP action VLAN ID is incorrectly allowed. |
| EXOS-36043 | SNMP trap notifications are sent despite a matching exclusion filter being configured. |
| EXOS-37033 | The fan LED index is incorrect when a fan failure occurs. |
| EXOS-37683 | An error message is generated when deleting SNMP users due to a missing configuration file reference. |
| EXOS-37872 | Node alias entries associated with backup and standby slot ports cannot be deleted via SNMP SET. |
| EXOS-39140 | IP multicast NAT does not work on a stack when the egress slot differs from the ingress slot. |
| EXOS-39261 | Running cable diagnostics may cause link instability and CRC errors. |
| EXOS-39401 | ExtremeCloud IQ Site Engine does not save configuration changes made via the cloud connector after a CLI asterisk (unsaved changes indicator) is present. |
| X690 Series Switches | |
| EXOS-34105 | The partition template command does not work on standalone X690 switches. |