The following issues were resolved in version 33.7.1. Version 33.7.1 includes all fixes up to and including versions 31.6, 31.7, 32.1, 32.2, 32.3, 32.4, 32.5, 32.6.x, 32.7.x, 33.2.1, 33.3.1, 33.4.1, 33.5.x, and 33.6.x.
| Defect Number | Description |
|---|---|
| General | |
| CFD-12612 | An IndexError: list assignment index out of range exception occurs when executing commands that convert a VLAN tag to a VLAN name. |
| CFD-14876 | Executing the show configuration command when the port display string contains German special characters causes a HAL process crash. |
| CFD-15767 | An L3VPN route is not programmed correctly in hardware after certain network events. |
| CFD-15830 | CLI sessions are not terminated based on the idle timeout configuration when the session was opened. |
| CFD-16145 | The port bitmap of a port dynamically added to a VLAN is returned when the dot1qVlanStaticTable is polled. |
| CFD-16355 | There is no CLI to configure the number of log entries stored on the switch. |
| CFD-16395 | Pressing q in the show port utilization bandwidth, packets, or bytes command output does not quit and continues to print the next page. |
| CFD-16644 | After adding a /32 route for an IP address that exists in the adjacency table, the switch does not accept new routes. |
| CFD-16710 | The output of the show slpp guard ports command does not quit properly. |
| CFD-16886 | FDB entries are not learned from received IGMP reports when the switch is in software learning mode. |
| CFD-16972 | A can't open /proc/1705/cmdline: no such file error message appears during switch bootup. |
| CFD-17056 | The NTP configuration is lost after a reboot when DHCP is enabled on the VLAN. |
| CFD-17087 | An SNMP error occurs after upgrading to version 32.7.3. |
| CFD-17194 | An error log message Failed to set fec config on port 1, rv = -18 appears after rebooting the switch. |
| CFD-17256 | BGP blackhole entry remains in the kernel after removing the corresponding NLRI entry from the BGP route policy. |
| EXOS-39140 | IP multicast NAT does not work on a stack when the egress slot differs from the ingress slot. |
| EXOS-39261 | Running cable diagnostics may cause link instability and CRC errors. |
| EXOS-39401 | ExtremeCloud IQ Site Engine does not save configuration changes made via the cloud connector after a CLI asterisk (unsaved changes indicator) is present. |
| EXOS-39547 | DHCP relay cannot be configured from ExtremeCloud IQ. |
| EXOS-39621 | When Instant-Port matches multiple device types where one has an Interlink action and another has an untagged VLAN action, the profile becomes invalid and fails to properly clean up actions when deleted. |
| Summit Stack | |
| CFD-16961 | The show slot output does not display the currently selected partition on the master slot. |
| CFD-17226 | The VM process is not initialized after a failover. |
| VPEX | |
| CFD-16670 | SNMP general errors occur when enforcing VLAN configuration to a VPEX stack from ExtremeCloud IQ Site Engine. |
| X440-G2 Series Switches | |
| CFD-16818 | Telemetry error messages are printed to the switch console. |