Resolved Issues in ExtremeXOS

The following issues were resolved in version 33.7.1. Version 33.7.1 includes all fixes up to and including versions 31.6, 31.7, 32.1, 32.2, 32.3, 32.4, 32.5, 32.6.x, 32.7.x, 33.2.1, 33.3.1, 33.4.1, 33.5.x, and 33.6.x.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 33.7.1
Defect NumberDescription
General
CFD-12612An IndexError: list assignment index out of range exception occurs when executing commands that convert a VLAN tag to a VLAN name.
CFD-14876Executing the show configuration command when the port display string contains German special characters causes a HAL process crash.
CFD-15767An L3VPN route is not programmed correctly in hardware after certain network events.
CFD-15830CLI sessions are not terminated based on the idle timeout configuration when the session was opened.
CFD-16145The port bitmap of a port dynamically added to a VLAN is returned when the dot1qVlanStaticTable is polled.
CFD-16355There is no CLI to configure the number of log entries stored on the switch.
CFD-16395Pressing q in the show port utilization bandwidth, packets, or bytes command output does not quit and continues to print the next page.
CFD-16644After adding a /32 route for an IP address that exists in the adjacency table, the switch does not accept new routes.
CFD-16710The output of the show slpp guard ports command does not quit properly.
CFD-16886FDB entries are not learned from received IGMP reports when the switch is in software learning mode.
CFD-16972A can't open /proc/1705/cmdline: no such file error message appears during switch bootup.
CFD-17056The NTP configuration is lost after a reboot when DHCP is enabled on the VLAN.
CFD-17087An SNMP error occurs after upgrading to version 32.7.3.
CFD-17194An error log message Failed to set fec config on port 1, rv = -18 appears after rebooting the switch.
CFD-17256BGP blackhole entry remains in the kernel after removing the corresponding NLRI entry from the BGP route policy.
EXOS-39140IP multicast NAT does not work on a stack when the egress slot differs from the ingress slot.
EXOS-39261Running cable diagnostics may cause link instability and CRC errors.
EXOS-39401ExtremeCloud IQ Site Engine does not save configuration changes made via the cloud connector after a CLI asterisk (unsaved changes indicator) is present.
EXOS-39547DHCP relay cannot be configured from ExtremeCloud IQ.
EXOS-39621When Instant-Port matches multiple device types where one has an Interlink action and another has an untagged VLAN action, the profile becomes invalid and fails to properly clean up actions when deleted.
Summit Stack
CFD-16961The show slot output does not display the currently selected partition on the master slot.
CFD-17226The VM process is not initialized after a failover.
VPEX
CFD-16670SNMP general errors occur when enforcing VLAN configuration to a VPEX stack from ExtremeCloud IQ Site Engine.
X440-G2 Series Switches
CFD-16818Telemetry error messages are printed to the switch console.