Pole Mounting AP-8163 with Band Clamps
Use the following procedure for mounting an AP-8163 with band
clamps:
- Attach the pole mount bracket section at the
desired mounting location using band clamps.
- With the angle adapter bracket section positioned so the open connector slots
are on the bottom, attach the angle adapter bracket section to the pole mount
bracket section using two 1/2 inch bolts and nuts. Tighten the nuts to 300 inch
pounds (lbf-in).
- Position the Access Point bracket section so the bottom of the section with the
straight (not bevel cut) sides is oriented toward the bottom side of the AP with
the gore vent. Using a torque wrench or a ratchet and a 10mm socket, or an
adjustable wrench, attach (but don‘t tighten) the Access Point bracket section
to the AP-8163 with the four M6 hex flange screws.
- Insert two M6 hex flange screws into the bottom holes on the sides of the
Access Point bracket section.
- With the Access Point positioned so the gore vent is facing down, insert the
two M6 hex flange screws in the bottom holes on the sides of the Access Point
bracket section into the open slot connections on the bottom of the angle
adapter bracket section.
- Rotate the Access Point bracket section upward and align the top holes on the
sides with the top holes on the angle adapter bracket section. Insert two M6 hex
flange screws into the top holes on the angle adapter bracket section. Use a
torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish
attaching the Access Point bracket section to the angle adapter bracket section
with the M6 hex flange screws in the open slot connections and the top holes on
the angle adapter bracket section. Do not tighten the screws until all rotation
and tilt adjustments are complete.
- To adjust the position of the Access Point, rotate the Access Point bracket
section (plus or minus 15 degrees) and tilt the angle adapter bracket section
(up to 45 degrees).
- Tighten all hex flange screws to 60 inch pounds (lbf-in).