With EFA 2.3.0 and later, you can upgrade
a multi-node deployment of EFA on TPVM (Third-Party Virtual Machine).
Before you begin
The EFA tar file must be available
on the
/efaboot
partition of the SLX device. You need root access to the device.
About this task
EFA on TPVM is supported only on the platforms described in Supported Platforms and Deployment Models.
The upgrade process prompts you to select secure mode or standard mode. For more
information about these modes, see EFA Installation Modes.
Installing EFA on a TPVM in a two-node deployment takes approximately 20 minutes.
Procedure
-
Enter SLX Linux mode.
device# start-shell
# cd /efaboot
-
Copy the EFA tar file to the SLX
device.
-
Deploy EFA on TPVM from the SLX
shell.
device# efa deploy
Starting "efa deploy", DO NOT hit CTRL+C
Step 1: Checking if TPVM is deployed ...
Step 2: Get IP Addressed assigned to TPVM to deploy EFA
IP Address of the TPVM 10.x.x.x
Step 3: Checking for EFA packages in /efaboot directory
Step 4: Deploying EFA package efa-2.x.x.tar.gz on 10.x.x.x
The EFA Installer begins in a series of dialogs.
-
When prompted, select Multi-node
deployment and OK.
Tip
Use arrow keys
to move between options and the space bar to select an option.
-
When prompted, select Enable secure
mode or Standard mode and
OK.
-
When prompted, enter the peer IP
address or FQDN of the other node in the cluster.
-
When prompted, enter the virtual
IP address for the cluster.
-
When prompted to configure
additional IP addresses for a health check, take one of the following
steps.
- Select Yes and
then provide the IP addresses.
- Select No to
ignore this optional step.
-
When prompted to configure
additional management IP networks, take one of the following steps.
- Select Yes and
then provide the following information when prompted. Repeat as often as
necessary.
- Sub-interface
name, which is a unique name that contains no more than 11
characters, no white space, and no % or /
characters.
- ID of the VLAN
that the management network uses to tag traffic. Valid values
range from 2 through 4093.
- IP subnet address
in CIDR format. The subnet must not overlap with any IP subnet
that you have already provided.
- Select No to
ignore this optional step or when you have finished entering
sub-interface information.
The upgrade proceeds.
Messages summarize your selections, describe the progress, and indicate when EFA
is deployed.
-
Verify the upgrade.
-
On the SLX device, run
the show efa
status command to see details of the installation and the
state of services.
-
From the EFA command
line, run the efactl status command to see the status of nodes, pods,
and services.
-
From the EFA command