The following issues were resolved in ExtremeXOS 22.3. ExtremeXOS 22.3 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, and ExtremeXOS 22.2. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
Summit X440-G2 Series Switches | |
xos0063038 | If a policy profile has tci-overwrite enabled and a rule
in that profile has a CoS index set with an index that has a meter with a
set-drop-precedence set to dot1p, the following message may appear:
<Erro:HAL.IPv4ACL.Error> ACL filter install failed on vlan *, port *, rule "policy.rule.cos.1.20.8" index -18, Invalid configuration |
xos0066461 | Adding VLANs to a port untagged using an SNMP set shows as untagged in the show configuration vlan command. |
xos0066945 | On Summit X440-G2 series switches, 10G ports are not coming up with 5-meter passive copper cable when connected to ExtremeSwitching X620-16X. |
xos0067493 | PTPv1 packets are dropped on the port if GPTP is enabled on the same port. |
xos0068466 | "Fan Failures RPM out of Range" messages appear on ExtremeSwitching X440-G2 series switches. |
Summit X450-G2 Series Switches | |
xos0060461 | Need command option for iBGP and eBGP protocols under the configure iproute ipv6 priority command. |
Summit X460-G2 Series Switches | |
xos0057796 | Power is momentarily denied to PoE devices connected on ports when a redundant PSU is inserted. |
xos0064795 | With a 4-node ERPS subring topology with no virtual channel, after link failure between two interconnect nodes, ring re-convergence, and then link restoration, traffic loss occurs for over 5 minutes. |
xos0066140 | RSTP BPDU is not transmitted even though STP state is in forwarding mode when loop-protect is enabled. |
xos0067064 | On Summit X460-G2-16mp-32p-10GE4 switches, SyncE does not work on the multi-speed supported ports (1–16). |
xos0067077 | In Summit X460-G2 alternate stacks, 10G links from the VIM-2T module of the backup slot go down after saving, and then rebooting. |
ExtremeSwitching X620 Series Switches | |
xos0065920 | Link status goes to Ready state on port with 10/100/1000BASE-T optics after multiple reboots. |
Summit X670-G2 Series Switches | |
xos0065571 | Ping fails over L3VPN tunnel when the corresponding ARPs are in Layer 3 hardware hash table as "Extended View". Affects Summit X450-G2, X670-G2, and X770 platforms. |
xos0065724 | Traceroute fails when the intermediate router is a VRRP gateway. |
xos0066844 | Port with copper SFP inserted appears as active even if it is administratively disabled. |
xos0068353 | For Summit X670-G2 series switches acting as a VRRP master, SSH session is not established for some prefixes after upgrading to ExtremeXOS 22.2. |
Summit X770 Series Switches | |
xos0053091 | On Summit X770 series switches, additional link flaps occur on 40G ports after reboot. |
xos0064590 | Port partitioning configuration is lost after a reboot if there is no physical cable attached to the partitioned port. |
xos0066761 | On Summit X770 series switches, CPU utilization of hal process is always high. |
xos0066963 | Jumbo frame is disabled on master port after rebooting when ports are partitioned. |
xos0066338 | On Summit X770 series switches and stacks, after configuring ports with partition 4x10G, saving and then rebooting produces the following error: Error: Failed to connect CLI for 91 seconds!. |
xos0067667 | On Summit X770 series switches, time drifts late over the period even after syncing with SNTP server. |
SummitStack | |
xos0058499 | In SummitStack, the snmpEngine values are maintained in each node separately instead of a single value, which is causing different values on each failover. |
xos0065970 |
In SummitStacks, unable to start process for python module; process name is not
recognized:
Error: Unknown process name EPM_Other2 |
xos0066104 | In SummitStacks, memory leak occurs in backup slot when configuring LLDP to advertise power-via-mdi with classification. |
xos0066331 | Layer 3 traffic is not forwarded after multiple stack failovers. |
xos0066423 | In SummitStacks, with policy re-authentication and continuous MAC move scenarios, ACL delete requests are failing in backup node. |
xos0066812 | On SummitStacks of X670G2 or X770 series switches, L2VPN is not supported. |
xos0060485 | MPLS process ends unexpectedly with signal 11 when changing the LSR ID. |
xos0065387 | SNMP times out while when saving on an eight-node stack of Summit X440 series switches. |
xos0065756 | In SummitStacks, alternate IP address is used for external communication even though a Management IP address is configured. |
xos0066085 | Restart of some processes does not work properly when the standby slot has a lower license level. |
xos0067096 | Multicast traffic is dropped on front panel port 1:1 when management port goes down on stacking switch. |
xos0067253 | IPv4 packets ingressing a non-master stack node can be dropped when the port number of the destination's ARP entry is unknown, such as when the destination is using Network Load Balancing (NLB). |
xos0060343 | On Summit X670v stack, configuration file replication on standby nodes times out after second or third failover. |
xos0067425 | Processes tBcmxSync or HAL may end unexpectedly during client authentication when policy and diffserv configurations are sent at least twice from Extreme Management Center NAC manager, or the diffserv replacement configuration is modified manually on the switch. |
ExtremeSwitching X870 Series Switches | |
xos0066044 | Auto-negotiation at 25G and 50G speeds is not supported on ExtremeSwitching X870 100G ports. Auto-negotiation is disabled by default for 25G and 50G ports. |
xos0066307 |
On ExtremeSwitching X870 series switches, IP security features may not work in conjunction with ONEPolicy. Messages similar to the following while enabling either feature may appear: Warn:ACL.Policy.IntAppConfFail&gt Failed to install dynamic acl esDhcpSnoop_deny_1 for internal applicaton IpSecurity on vlan client port 23. Error: ACL install operation failed - filter hardware full for vlan client, port 23. Erro:Policy.CfgHwRsrcFail&gt Slot-1: Failed to reserve hardware rules of type unknown. |
xos0066764 | Traffic is forwarded without CVID tag on untagged VMAN ports after adding VMAN to VXLAN. |
xos0066998 | On ExtremeSwitching X870 series switches, not all policy rules are able to be written depending on the order that they are applied. |
xos0067183 | On ExtremeSwitching X870 series switches, kernel crash occurs randomly booting up switch with virtual router and mirroring configuration. |
xos0068223 | On ExtremeSwitching X870 series switches, very infrequently when running extended diagnostics, "Test loopback phy fiber - FAIL"and "Test snake interface - soc_phyctrl_loopback_set: u=0 p=5 TIMEOUT" errors occur. |
General | |
xos0061317 | Switch reboots unexpectedly when enabling FIP snooping. |
xos0063551 | SNMP polling on CFM segment frame-delay statistics returns incorrect values. |
xos0063669 |
Erro:RtMgr.Client.ReplyTimeOut messages appear after run failover/reboot: <Warn:EPM.hello_rate> Slot-2: Received hellos from process rtmgr 2 more often then expected 3 <Erro:RtMgr.Client.ReplyTimeOut> Slot-2: Client with ID=0x00000012 Timed out waiting for (ADDUPDRTE). <Erro:RtMgr.Client.ReplyTimeOut> Slot-2: Client with ID=0x00000012 Timed out waiting for (RTEGET). |
xos0064138 | Client identifier option length in DHCPv6 solicit packet is 16 instead of 14 with Link layer address padded with zeroes. |
xos0064633 | Lacking support for Entity Sensor MIB, as well as Entity Sensor MIB Extensions. These MIBs are needed to present digital diagnostics information for the transceivers. |
xos0064680 | STP port-specific configuration is lost after disabling load sharing or moving the port to a different VLAN. |
xos0064727 | On DHCPv6 clients, sometimes the IPv6 address is not removed even after disabling the client, and after rebooting, the IPv6 address is saved and this causes the client to go into a stopped state with the following error message appearing: <Erro:vlan.AddIPAddrFail> Failed to add IP addr 8001::4aa6:dd38:9b32:e7b/128 from DHCPv6 to VLAN client, DHCPv6 configured IPv6 address already exist on interface client |
xos0064870 | Slots fail sometimes when applying PVLAN and STP configuration. |
xos0064975 | Ejecting a memory card using the eject memorycard command changes the switch configuration so that it does not save core dump files to memory or a removable storage device. |
xos0064983 | Optics information does not appear properly for Enterasys SFP+ 10GBASE-ER. |
xos0065210 | With account lockout feature configured, an appropriate log message is not generated when users are locked out after three unsuccessful login attempts. |
xos0065321 | With SSH session, source address information is not sent to TACACs accounting server. |
xos0065400 | VLAN name and tag do not appear correctly when VLAN is created with VLAN name as "tag". |
xos0065654 | Etmon process ends unexpectedly with signal 10 when packet size in sampled packet is a negative integer. |
xos0065764 | Link status goes to ready state on ports with 10/100/1000BASE-T optics after multiple reboots. |
xos0065946 | SNMP get for lldpRemSysCapSupported MIB returns incorrect value. |
xos0065977 | Random Nettools process ends unexpectedly with Signal 5 when router discovery and DNS is enabled. |
xos0066029 | In Summit X460-G2 stacks, LACP keeps flapping due to forwarding one LACP PDU to another group. |
xos0066030 | L2PT is not working properly after path switchover in VPWS. |
xos0066059 | CLI cursor jumping when word wrapping when using SSH session. |
xos0066072 | The command configure ports rate-limit flood out-actions disable-port does not take effect until the command clear meter out-of-profile is executed. |
xos0066156 | Switch reboots unexpectedly due to memory leak in dot1ag process. |
xos0066170 | Kernel crash occurs sometimes when ip-arp fast convergence is enabled. |
xos0066345 | XMLC process ends unexpectedly with signal 6 when sending XML notification to Ridgeline server. |
xos0066386 | The show configuration command stops responding and produces an error when there is a loop in the network. |
xos0066462 | Copying a file to the cfg directory causes the switch to stop responding. |
xos0066472 | Executing debug hal show compact-flash command returns kernel mismatch error. |
xos0066477 | Creating a VLAN starting with "vr" causes syntax recognition problems with the show iparp vr command. |
xos0066483 | The encrypted shared secret for TACAS accounting secondary servers does not appear in the configuration. |
xos0066610 | Error "Cannot open Python script" appears after executing a Python script stored under a user-created subdirectory. |
xos0066838 | When configuring a "legacy" RADIUS-Accounting server with a DNS-resolved hostname, the hostname is lost after a reboot (or similar circumstances, such as multiple failovers). |
xos0066839 | When debug packet capture is enabled for a port, pcap file is not created in internal-memory. |
xos0066932 | Actual/configured sFlow sample rates are different after reconfiguring. |
xos0066984 | RADIUS-accounting request packet shows incorrect account-terminate reason for user logout from SSH session. |
xos0067138 | BFD is not working for IP static multicast route. |
xos0067158 |
You cannot synchronize a master switch running a version earlier than ExtremeXOS 22.2 to a target node running ExtremeXOS 22.2 or later. The command fails and the following error message appears:
Error: the target slot's partitions are not compatible with the Master's for synchronize. |
xos0067206 | Unable to login to Chalet with any account that uses an ampersand (&) character. |
xos0067739 | UDP configuration is lost after reboot with IP DAD enabled. |
xos0067820 | ExtremeXOS refuses connections with usernames starting with letters h, i ,j, k, p, q, r, and s using SOAP/XML. |
xos0067877 | NTP restrict-list is failed when adding ipadress without vr keyword. |
xos0068424 | EDP process ends unexpectedly when a CDP packet without version details in software version TLV is received. |
xos0068531 | System CPU utilization is not accounting for CPU utilization for some Kernel threads in the output of the command show cpu-monitoring. |
xos0064624 | On ExtremeSwitching X620 series switches, when using optic SPG-DR-LX-CDFC-EX from Source Photonics, there is a traffic issue. |
xos0068752 | Kernel crash occurs when processing a packet with an invalid IP header length. |
xos0068750 | AAA process ends unexpectedly with signal 11 when processing a corrupted RADIUS-challenge packet. |
xos0067161 | LACP flap occurs when disabling the mirror on port where LAG is configured with LACP. |
xos0067492 | Documentation should indicated that ExtremeXOS does not notify you when configuration settings for a stack are inappropriate for a node in the stack. |
xos0067546 | EPM process ends unexpectedly when SSH process is restarted while SNMP query on memory statistics is still in progress. |
xos0067841 | Packets are dropped at ingress port for traffic at a rate greater than 1,000 pps when 500 ACLs are installed. |
ACL | |
xos0054222 | Unable to add second IPv6 address prefix to the network-zone after adding IPv4 address. |
xos0065930 | ACLCBFUNC log occurs after associating a policy that has CLEAR-flow and network-zone configuration. |
xos0067912 | The command show port protocol filter displays the "Error: Configuration reply is too big" in output. |
BGP | |
xos0052432 | Need provision for advertising/receiving unique local IPv6 unicast address (ULA) using BGP protocol. |
xos0052786 | BGP aggregation command demands global unicast addresses (GUA) and does not work with IPv6 unicast addresses. |
xos0063959 | BGP routes become unfeasible when default routes are advertised through OSPF or BGP. |
xos0065742 | SNMP traps are not generated for BGP state change events. |
xos0066775 | Configured peer group capabilities and policies are not reflected after creating a new BGP neighbor. |
Clocking | |
xos0064859 | In SummitStack, gPTP process ends unexpectedly during bootup if AVB license was enabled on any of the stack nodes. |
EAPS | |
xos0067203 | Multicast packets are flooded on EAPS-blocked ports after removing and then adding ports configured with PSTAG. |
ELRP | |
xos0064923 | When a remote loop is detected by ELRP (ingress and egress port of loop detection is the same) an excessive number of log messages occur. |
xos0065788 | After deleting a port, disabled by ELRP, from a VLAN, the port remains disabled. |
xos0066895 | ELRP process ends unexpectedly when a loop is detected in the switch. |
ERPS | |
xos0065805 | Constant flush happens in ERPS non-revertive mode when the port being blocked is non-RPL. |
xos0066367 | Need to have a "clear" command to change ERPS ring state from "pending" to "idle" state. |
xos0066489 | Loop occurs in ERPSv2 setup after rebooting one of the interconnecting nodes. |
xos0066490 | ERPS in non-RPL nodes remains in pending state after rebooting interconnection node. |
xos0067325 | After recovering from multiple link failures, ERPS incorrectly keeps both the ring links in blocked state. |
ESRP | |
xos0066996 | ESRP does not update the neighbor state properly while becoming master from neutral state. |
FDB | |
xos0066885 | FDB is not removed in software after ageing period. |
xos0067271 | FDB mismatch occurs between software and hardware after deleting, and then adding, ISC port multiple times. |
IP General | |
xos0050804 | IPv6/PIMv6: The FHR does not respond with neighbor advertisements when it is also sending PIM register packets; the RP is sending neighbor solicitations. (The FHR found within a multi-access network temporarily floods the RP with register packets even if Register Stop messages are received when traffic is started.) |
xos0061488 | Decompressed routes are not programmed into hardware after disabling IPv4 compression. |
xos0061489 | Compressed routes are not programmed into hardware when master route fails. |
xos0065615 | Local multicast traffic is not egressing using a newly added member port in a LAG. |
xos0066006 | When ICMP redirect is received and the new gateway ARP is not resolved, the redirect route becomes valid and is used. This results in traffic being dropped. This problem is more apparent when the redirection happens to a host on a different subnet because ExtremeXOS enables IP ARP checking by default. |
xos0066444 | Kernel error "Unable to copy IPMC index" appears in MLAG peers with PIM dense mode. |
xos0066590 | In an MLAG peer when its MLAG port is down, the following error appears: "Group <ip> not found for VLAN". |
xos0066772 | Local multicast fast-path forwarding does not work for a few ports when IGMP filter is in per-VLAN mode. |
xos0066806 | PIM checkpointing loop occurs between two switches that have two ISCs over two VRs. |
xos0066921 | ARP fails to resolve for some hosts. |
xos0066950 |
Hash collision error messages may appear when there is contention for the L3 Hash
table:
<Warn:Kern.IPv4Adj.Warning> vrId 0 adj 0x00000002 Error finding adjacency when deleting hash collision. |
xos0067063 | Rtlookup is not able to display all the ECMP routes. |
xos0068023 | Hash collision warning message appears with invalid VRID when exceeding L3 hash table limit. |
xos0068209 | PIM process ends unexpectedly with signal 11. |
MLAG | |
xos0066323 | When MLAG is configured with alternate path and ISC link goes down, a peer down log message is not generated. |
xos0066325 | When MLAG is configured with alternate path and primary path goes down, SNMP trap for ExtremeMlagPeerDown object is not generated. |
xos0066923 | Need commands to configure "reload-delay" timer for MLAG ports. |
xos0066787 | In ExtremeXOS User guide, need to add a recommendation regarding MLAG with LACP implementation. |
MPLS | |
xos0065372 | MPLS error messages occur after disabling, and then enabling network VLANs. |
xos0065987 | Service port FDB entries are learned on physical port of Network VLAN in provider switch. |
xos0066366 | On VPLS network with LAG on access side, clearing FDB on LSRs and LERs results in traffic drop. |
xos0066476 | MPLS label TTL is not set properly for VPLS traffic in RSVP-TE. |
xos0066782 | BFD session ends when removing CVID from a service VMAN port. |
xos0066813 | Service VLAN ARP packets are lifted to the CPU during MPLS swap operation when service a VLAN is configured with the IP address of the provider switch. |
xos0067084 | FDB is not learned over pseudowire after disabling, and then enabling, learning on network VLAN ports. |
xos0067323 | FDBs are learned on incorrect VPLS peer on PE switches after include/exclude dot1q tag in P switch. |
xos0067463 | Traffic does not distribute across LSPs and LAG after enabling L2VPN sharing feature. |
NetLogin | |
xos0062680 | Switch fails to send RADIUS accounting message for dot1x user after clear netlogin state port &ltportNumber&gt command. |
xos0062758 | With policy enabled, client authenticated using NetLogin is not getting aged out when reauthentication is configured. |
xos0065648 |
When a MAC address moves from a NetLogin-enabled port (mac-vlan mode) to a
non-NetLogin-enabled port, the VLAN_MAC table can become full resulting in the
following message:
&ltWarn:HAL.FDB.MacVlanAddFail&gt MAC-based VLAN entry 78:7E:61:A1:DC:DC vlan 2600 addition to port 22 failed, Table full |
xos0066224 | User name is missing from output of show log command for NetLogin users when they are cleared by link down/restart process NetLogin event immediately after reboot. |
xos0066231 | With default NetLogin configuration, extremeNetloginuser login and logout traps are not sent. |
xos0066538 | With web-based NetLogin enabled, cannot access the device using URL "http://network-access.com/login". |
xos0066626 | NetLogin process ends unexpectedly with signal 11 when RADIUS accept packet contains MS-ipv4-remediation-servers attribute with an incorrect IP address. |
xos0066770 | Memory leak occurs in aaa process when NetLogin dot1x client times out or authentication fails for the client. |
xos0066982 | In NetLogin dot1x, RADIUS retries are not working properly. |
xos0067106 | In dot1x authorization, service unavailable vlan port is re-authenticated in every authorization causing blocked port. |
xos0068215 | Logout dialog box appears even after disabling Netlogin logout-privilege. |
xos0068302 | With both HTTP and HTTPS enabled, sending HTTP request from NetLogin client causes the switch to return with HTTP response instead of HTTPS. |
xos0068454 | In ISP mode, if no ports are associated with the NetLogin VLAN, then the client cannot access the base URL. |
xos0068660 | Session-timeout value from RADIUS server does not have higher precedence over value provided from CLI. |
xos0068698 | In NetLogin web, after you click the logout button, you are not redirected to a page with the message “You have logged out”. |
OSPF | |
xos0051490 | External LSA generated by an ASBR in NSSA area contains wrong forwarding address. |
xos0065830 | After port flaps, OSPF-learned routes are not present in kernel database. |
xos0066804 | Routes learned from OSPF are lost after multiple port flaps occur. |
xos0066986 | OSPF E1 routes in NSSA area are removed or not updated properly in the routing table. |
Security | |
xos0062037 | DHCP snooping entry gets programmed without client port number. |
xos0064588 | Policy profile and policy rules may appear without a complete description of the fields. |
xos0065354 | Kernel error "packet number to save out of range: 49" occurs when DOS protect is enabled in the switch. |
xos0065505 | You are not notified that the configuration is not allowed when configuring policy mode authentication optional on NetLogin web-enabled ports. |
xos0065552 | RADIUS-accounting request packet shows incorrect reason for client termination. |
xos0066135 | If policy is removed from a port/VLAN that is in the Spanning Tree Blocking state, network loops may occur. |
xos0066380 | NetLogin sessions with policy enabled persist after a port/VLAN transitions into a blocking state. |
xos0066398 | CoA disconnects are incorrectly logged as idle timeouts in EMS. |
xos0066446 | A Change of Authentication request can inadvertently create a new session if a matching existing authentication for the request is not present. |
xos0066611 | ExtremeXOS implementation of RADIUS inappropriately requires Message-Authenticator attribute in CoA-Request and Disconnect-Requests. |
xos0066634 | Summit X460-G2 series switches policy rule limits are set too high. |
xos0066662 | RADIUS CoA re-authentication requests reauthenticate all agents (MAC/dot1x/web), rather than only active agents if an agent is not specified in the request. |
xos0066874 | Memory leak occurs in AAA process when dot1x clients are authenticated frequently. |
xos0066877 | In TACAS, NetLogin, and SNMPv3, encrypted form of configured password is changing after every save command. |
xos0067076 | NetLogin process ends unexpectedly while fetching the client details using SNMP MIB etsysMACAuthenticationMACSession and it happens only when there is MAC move observed for the clients. |
xos0067079 | ACL installation for the policy authenticated client is failing when diffserv replacement and meter configuration is present in the switch. |
xos0067167 | When switching the policy profile authentication override from disable to enable with a static rule configured, NetLogin session is not created even though the MAC address(es) are programmed in FDB. |
xos0067179 | Both MAC and CEP NetLogin sessions exist with authentication override enabled in certain configuration and traffic scenarios. |
xos0067227 | IDMgr entries are not flushed when ARP fast-convergence is on. |
xos0067963 | After configuring IP security, if the VLAN name is changed, the change is not reflected in the command show configuration ipsecurity. |
xos0068356 | Informational messages appear on the console when an NTP-enabled VLAN becomes inactive. |
xos0068722 | Policy-enabled port is removed from VLAN when it is added as untagged using SNMP/ATG tool. |
xos0068710 | Additional NetLogin traps are sent when switch is configured to send only max-users-reached trap. |
SNMP | |
xos0062668 | MIB compilation issues occur with VLAN MIB when using mgsoft. |
xos0065943 | SNMP walk for extremePortUtilizationTable returns integer value, but CLI output returns decimal value. |
xos0066012 | ExtremeXOS MIBs have non-compilable errors. |
xos0066735 | The etsysVlanAuthorizationMIB MIB definition is not incorporated into ExtremeXOS. |
xos0068632 | In ExtremeXOS User Guide for the EXTREME-PORT-MIB, the extremePortMauTable table shows incorrect information. |
SSH | |
xos0063806 | After establishing SSH session with switch for some time, SSH login fails and the command show management becomes unresponsive. |
xos0063856 | After enabling SSH2, key generation time appears as approximately 15 minutes when it actually takes less than one minute. |
xos0064864 | Switch can go into reboot loop if the length of configured SSH private key is different from the actual key stored in EEPROM. This can happen when you attempt to configure an invalid key or when loading a .cfg file containing an SSH private key from another switch onto a new switch with default setting. |
xos0065712 | When repeated login and logout is performed using SSH-PKI (SSH login using certificates) for about two days from eight terminals, memory leak occurs. |
xos0066027 | After downloading certificates, the commands show ssl trusted-ca and show ssl ocsp-signature-ca fail to show any output. However, PKI validation that makes use of these certificates works. |
xos0066758 | SSH login fails in first attempt, but succeeds in the second attempt, during RADIUS authentication even if credentials are valid. |
xos0066931 | Exsshd process consumes ~90% CPU when the command clear session is executed for the open SSH sessions. |
xos0067055 | Log message "Process exsshd sends hello too often" appears when SSH is enabled in the switch. |
xos0067182 | Authentication on switch using RSA keys stops working if one of the user keys is deleted. |
xos0067704 | The process exsh ends unexpectedly after issuing command with include option that uses # via SSH script. |
xos0067887 | Switch reboots unexpectedly when there are continuous SSH attempts and those attempts are rejected with access-profile. |
xos0068556 | SSH with command argument as "show commands" is not working with user account. |
STP | |
xos0064798 | Configured port‘s STP properties are lost when the port is moved from one VLAN to another. |
xos0066559 | In ExtemeXOS User Guide, need to add a recommendation regarding STP with L2-fast-convergence. |
xos0066837 | When the switch is rebooted, the edge port gets blocked even though the STP domain is disabled. |
xos0066919 | When loop protect occurs on the switch, need to log an event message and send a trap |
xos0067108 | Packets received on STP-blocked ports get forwarded to other STP ports when NetLogin and ONEPolicy are enabled with authentication mode optional. |
xos0067194 | Topology change notification is not generated for the STP domain dot1d mode when there is change in the topology. |
xos0067560 | Globaly disabling STP takes longer to converge when loop protection is enabled. |
xos0068283 | ExtremeXOS is transmitting BPDUs with the agree bit in the flags field persistently clear. |
xos0068415 | STP backup root feature is not activated after disabling STP on master root. |
VLAN | |
xos0066557 | Kernel crash occurs after removing a subVLAN from one VR and adding the same subVLAN in another VR. |
xos0066891 | Packets are being forwarded without a tag after rebooting when PSTAG configured. This issue occurs when VLANs are configured with VID as "1". |
xos0066926 | Errors occur when configuring OpenFlow in passive mode. |
xos0067048 | Multicast traffic is not forwarded on PStag ports when port is also added as part of another non-PStag VLAN. |
xos0067243 | When adding untagged ports to a VLAN using Q-BRIDGE MIB, ports are added in the MAC-BASED VLAN. |
xos0067244 | Able to add same port as tagged and untagged in a VLAN using Extreme Management Center console. |
VRRP | |
xos0061817 | VRRP fabric routing is not supported for VRRP owner address (configuring at priority 255). |
VXLAN | |
xos0066883 | Process HAL ends unexpectedly with signal 11 on restarting all ports with basic VXLAN configuration. |
XML | |
xos0067822 | Memory leak occurs in XMLD process whenever Chalet session refresh happens. |
XNV | |
xos0061611 | FDB entry from base VLAN is not removed after restarting XNV dynamic VLAN-enabled ports. Issue occurs when clearing FDB also. |
xos0064338 | After creating XNV dynamic VLAN with XNV enabled at MLAG port (and its corresponding ISC Port), FDB entry for tracked MAC is learned on base VLAN instead of dynamic VLAN causing flooding and FDB issues. |
xos0067335 | Memory leak occurs in VMT process when it is enabled on the port. |