The following issues were resolved in ExtremeXOS 22.5.1-Patch1-7. ExtremeXOS 22.5.1-Patch1-7 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, and ExtremeXOS 22.5. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0071418 | Ports configured for BPDU restriction are re-enabled on recovery-timeout even if administratively disabled. |
xos0072698 | VRRP crash occurs when host mobility is configured and new host routes are learned continuously. |
xos0073473 | Kernel crash occurs randomly after flapping the ports through which LSP is established. |
xos0073818 | Packets originating in a switch fail to egress after removing the ports from service VLAN. |
xos0074040 | Layer 2 protocols (EAPS, ERPS, STP) take 15 seconds to converge with Edge license installed. |
xos0074176 | CPU-originated packets are double tagged with an incorrect outer tag of zero if they originate from master and egress out of a non-master node through another transit slot. |
xos0074195 | Continuous DM error messages are logged if MLAG and STP are configured on stacks containing ONIE series switches (X870, X690). |
xos0074374 | ExtremeXOS does not support port VLAN monitoring on PSTAG ports |
xos0074392 | The process rtmgr ends unexpectedly with signal 11 after deleting a VLAN. |
xos0066220 | The show tech process does not exit automatically after the Telnet session that triggered it is terminated. |
xos0073804 | The process rtmgr ends unexpectedly with signal 11 after changing the gateway of L3VPN routes. |
xos0072176 | DNS resolves on wrong VR. |
xos0074187 | After a Fabric Attach client reboot or after disabling/enabling a port, the uplink port is not added to a dynamic VLAN on the Fabric Attach proxy. |
xos0074306 | Connecting with Telnet to hostname on VR-Default fails. |
xos0074544 | Downloading ExtremeXOS image to backup/standby node in a stack fails due to TFTP block number limitation. |
ExtremeSwitching X870 Series Switches | |
xos0073880 | In policy, redirect-port-list action modifier does not work properly for LAG ports. |
xos0074448 | On ExtremeSwitching X870-96x-8c switches, optics incorrectly initialize when using default partition configuration. |
Summit X460-G2 Series Switches | |
xos0073360 | Random port flaps occur on Summit X460-G2-10G ports. |