Resolved Issues in ExtremeXOS 22.5.1-Patch1-7

The following issues were resolved in ExtremeXOS 22.5.1-Patch1-7. ExtremeXOS 22.5.1-Patch1-7 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, and ExtremeXOS 22.5. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 22.5.1-Patch1-7

CR Number Description
General
xos0071418 Ports configured for BPDU restriction are re-enabled on recovery-timeout even if administratively disabled.
xos0072698 VRRP crash occurs when host mobility is configured and new host routes are learned continuously.
xos0073473 Kernel crash occurs randomly after flapping the ports through which LSP is established.
xos0073818 Packets originating in a switch fail to egress after removing the ports from service VLAN.
xos0074040 Layer 2 protocols (EAPS, ERPS, STP) take 15 seconds to converge with Edge license installed.
xos0074176 CPU-originated packets are double tagged with an incorrect outer tag of zero if they originate from master and egress out of a non-master node through another transit slot.
xos0074195 Continuous DM error messages are logged if MLAG and STP are configured on stacks containing ONIE series switches (X870, X690).
xos0074374 ExtremeXOS does not support port VLAN monitoring on PSTAG ports
xos0074392 The process rtmgr ends unexpectedly with signal 11 after deleting a VLAN.
xos0066220 The show tech process does not exit automatically after the Telnet session that triggered it is terminated.
xos0073804 The process rtmgr ends unexpectedly with signal 11 after changing the gateway of L3VPN routes.
xos0072176 DNS resolves on wrong VR.
xos0074187 After a Fabric Attach client reboot or after disabling/enabling a port, the uplink port is not added to a dynamic VLAN on the Fabric Attach proxy.
xos0074306 Connecting with Telnet to hostname on VR-Default fails.
xos0074544 Downloading ExtremeXOS image to backup/standby node in a stack fails due to TFTP block number limitation.
ExtremeSwitching X870 Series Switches
xos0073880 In policy, redirect-port-list action modifier does not work properly for LAG ports.
xos0074448 On ExtremeSwitching X870-96x-8c switches, optics incorrectly initialize when using default partition configuration.
Summit X460-G2 Series Switches
xos0073360 Random port flaps occur on Summit X460-G2-10G ports.