The following are new open issues for supported features found in ExtremeXOS 22.6.1-Patch1-8.
CR Number | Description |
---|---|
ExtremeSwitching X620 Series Switches | |
xos0072580 | For ExtremeSwitching X620 series switches, after applying policy configuration
changes with disable policy and enable policy on a LAG
master port that is in down state, NetLogin authentication may fail on the port.
Workaround: Run the command clear netlogin
state
port
LAG master port to reinstate NetLogin on the port.
|
BGP Auto-peering | |
xos0072783 | VLAN process ends unexpectedly when disabling all remote VXLAN tunnel end points using the command disable virtual-network remote-endpoint vxlan all. |
Extended Edge Switching | |
xos0072443 | With mirroring configuration, the following error appears when rebooting 1st
tier bridge port extender (BPE) in an Extended Edge
Switching
topology:<Erro:HAL.Mirror.Error> Slot-1: Failed to add mirroring source 162:1 on unit 0, Invalid port <Erro:HAL.Mirror.Error> Slot-1: Failed to add mirroring source 161:1 on unit 0, Invalid port |
xos0072839 |
In a topology with redundant controlling bridges (CBs) with attached MLAG'd
bridge port extenders (BPEs) connected on regular ports, and a non-MLAG'd BPE that
is connected on a 40G port, if you perform the following steps:
The non-MLAG BPE remains in the booting state and times out with the error
similar to the
following:
08/16/2018 22:05:14.65 <Erro:STP.InBPDU.Drop> Slot-1: Port=1:15: No associated STP port for STP Domain tag 1 (Rate-limited) 08/16/2018 22:05:24.14 <Info:HAL.Card.Info> Slot-1: Unable to get MLAG Peer CB & BPE info for slot 116 08/16/2018 22:05:26.15 <Info:HAL.Card.Info> Slot-1: Unable to get MLAG Peer CB & BPE info for slot 117 08/16/2018 22:05:26.66 <Erro:STP.InBPDU.Drop> Slot-1: Port=115:8: No associated STP port for STP Domain tag 1 (Rate-limited) 08/16/2018 22:05 08/16/2018 21:23:59.49 <Erro:STP.InBPDU.Drop> Slot-1: Previous message repeated 14 additional times in the last 13 second(s) 08/16/2018 21:23:59.19 <Erro:DM.Error> Slot-1: Skipping set_card_state(117, POWERON) as card state is UNKNOWN instead of FAILED 08/16/2018 21:23:58.62 <Erro:STP.InBPDU.Drop> Slot-1: Port=115:8: dropping PDU as MLAG masterStatus not ready yet 08/16/2018 21:23:57.44 <Erro:STP.InBPDU.Drop> Slot-1: Port=115:8: dropping PDU as MLAG masterStatus not ready yet 08/16/2018 21:23:57.18 <Info:HAL.Card.Info> Slot-1: Slot-117 down, resetting all TCP connections to it 08/16/2018 21:23:57.18 <Info:HAL.Card.Info> Slot-1: Module in Slot-117 is removed 08/16/2018 21:23:57.16 <Erro:DM.Error> Slot-1: Skipping set_card_state(116, POWERON) as card state is UNKNOWN instead of FAILED 08/16/2018 21:23:56.65 <Erro:STP.InBPDU.Drop> Slot-1: Port=115:8: dropping PDU as MLAG masterStatus not ready yet 08/16/2018 21:23:56.15 <Warn:DM.Warning> Slot-1: Slot-117 FAILED (1) CardExec (state BOOTING) timed out 08/16/2018 21:23:56.15 <Warn:DM.Warning> Slot-1: Slot-117 Timeout in State BOOTING 08/16/2018 21:23:55.46 <Erro:STP.InBPDU.Drop> Slot-1: Port=115:8: dropping PDU as MLAG masterStatus not ready yet |
xos0072936 | When using Extended Edge
Switching full automation with multiple controlling bridge
(CB) MLAG peer candidates, automation stops (as designed), but displays errors due
to clean-up effort that involves deleting non-existent VLANs. Workaround: Have only one CB MLAG candidate connected when using full
automation, or use partial-automation (have configuration on the CB, configure
MLAG peer, and then issue the command enable vpex
auto-configuration.
|
Diagnostics | |
xos0072841 |
Operational diagnostics version 3.0 for ONIE series switches (released with ExtremeXOS 22.6) may fail to run due to a hardware watchdog expiration prior to the diagnostics application taking over the watchdog. Since the 3.0 version of diagnostics is only required for ExtremeSwitching X590 series switches, you can leave the previous version 2.6 installed on ExtremeSwitching X870 or X690 series switches and continue to use that version. Workaround: For installations that are already
upgraded to 3.0 using the 22.6 diagnostics XMOD, and see this issue, two
workarounds are possible:
|
NetLogin | |
xos0070151 | Profile changes made through Change of Authorization (CoA) are applied to the
authenticator, but not to remote peer using NetLogin and MLAG, so that the peer
entry remains in the old profile. Workaround: Use SNMP
instead of CoA with Captive Portal feature.
|
Optics | |
xos0072483 | ExtremeSwitching X690, X870 and X590 series switches do not support 100G Optic/AOC cables on stacking ports. |
VXLAN | |
xos0072043 | On an unconfigured switch, adding a static route by a VXLAN tunnel with traffic
flowing may cause a warning message in the log. The condition is harmless and can be
ignored. There will be about a dozen messages in the log, with the main identifying
message being similar to: WARNING: CPU: 0 PID: <XYZ> at kernel/softirq.c:146 __local_bh_enable_ip+0x7a/0xa0() Workaround: Save the configuration, and then
reboot.
|
xos0071205 | On Summit X670-G2 and X770 series switches, when using scripts to issue OSPF commands, OSPF takes longer to arrive, and stay, in full state with 2K virtual networks after rebooting. |
xos0071204 | On Summit X670-G2 and X770 series switches, when creating/discovering a large number of VXLAN remote termination endpoints (RTEPs), the start of forwarding of broadcast traffic might be delayed. |